bioRxiv Science⌕ Search

Biology subjects

Pashkova, A.

Publications and source records attributed to Pashkova, A..

7 recordsLinked to original sources

Evaluation of an Orbitrap Astral Zoom mass spectrometer prototype for quantitative proteomics - beyond identification lists

Mass spectrometry instrumentation continues to evolve rapidly yet quantifying these advances beyond conventional peptide and protein detections remain challenging. Here, we evaluate a modified Orbitrap Astral Zoom mass spectrometer (MS) prototype and compare its performance to the standard Orbitrap Astral MS. Across a range of acquisition methods and sample inputs, the prototype instrument outperformed the standard Orbitrap Astral MS in precursor and protein identifications, ion beam utilization, and quantitative precision. To enable meaningful cross-platform comparisons, we implemented an ion calibration framework that converts signal intensity from arbitrary units to ion per second. This benchmarking strategy showed that the prototype sampled 30% more ions per peptide than the original Orbitrap Astral MS. This increase in the ion beam utilization resulted in improved sensitivity and quantitative precision. To make these metrics broadly accessible, we added new metrics to the Skyline document grid to report the number of ions measured in a spectrum at the apex of the elution peak or the sum of ions between the peak integration boundaries. Taken together, our results demonstrate the prototype Orbitrap Astral Zoom as a high-performance platform for DIA proteomics and establish a generalizable framework for evaluation of mass spectrometer performance based on the number of ions detected for each analyte. Data are available on Panorama Public and on ProteomeXchange under the identifier PXD064536.

biochemistry↗

Narrow window data-independent acquisition on the Orbitrap Astral Mass Spectrometer enables fast and deep coverage of the plasma glycoproteome

Recently, a conceptually new mass analyzer was introduced by pairing a quadrupole Orbitrap mass spectrometer with an asymmetric track lossless (Astral) analyzer. This system provides >200-Hz MS/MS scanning speed, high resolving power and sensitivity, and low-ppm mass accuracy. This instrument allows a narrow-window data-independent (nDIA) strategy, improving sensitivity and reproducibility even when using very short LC gradients. Although this represents a new technical milestone in peptide-centric proteomics, this new system has not yet been evaluated for the analyses of very complex and clinically important proteomes, such as represented by the plasma glycoproteome. Here, we evaluated the Orbitrap Astral mass spectrometer for the analysis of the plasma glycoproteome, and pioneer a dedicated nDIA workflow, themed nGlycoDIA. With substantially adjusted parameters and varying collision energies, nGlycoDIA has clear benefits for plasma glycoproteomics. We tested our method both in glycopeptide enriched and crude plasma, leading to the identification of more than 3000 unique glycoPSMs from 181 glycoproteins, covering a dynamic range of 7 orders of magnitude in the enriched plasma sample in just 40 minutes. In addition, we detect for the first time several glycosylated cytokines that have a reported plasma concentration in the ng/L range. Furthermore, shortening the gradient to 10 min still allows the detection of almost 2500 unique glycoPSMs from enriched plasma, indicating that high-throughput indepth clinical plasma glycoproteomics may be within reach.

biochemistry↗

Paradigm shift in biomarker translation: a pipeline to generate clinical grade biomarker candidates from DIA-MS discovery

Clinical biomarker development has been stymied by inaccurate protein quantification from mass spectrometry (MS) discovery data and a prolonged validation process. To mitigate these issues, we created the Targeted Extraction Assessment of Quantification (TEAQ) software package. This innovative tool uses the discovery cohort analysis to select precursors, peptides, and proteins that adhere to established targeted assay criteria. TEAQ was applied to Data-Independent Acquisition MS data from plasma samples acquired on an Orbitrap Astral MS. Identified precursors were evaluated for linearity, specificity, repeatability, reproducibility, and intra-protein correlation from 11-point loading curves under three throughputs, to develop a resource for clinical-grade targeted assays. From a clinical cohort of individuals with inflammatory bowel disease (n=492), TEAQ successfully identified 1116 signature peptides for 327 quantifiable proteins from 1180 identified proteins. Embedding stringent selection criteria adaptable to targeted assay development into the analysis of discovery data will streamline the transition to validation and clinical studies.

biochemistry↗

One-Hour Phosphoproteome Analysis with the Orbitrap Astral Mass Spectrometer

Owing to its roles in cellular signal transduction, protein phosphorylation plays critical roles in myriad cell processes. That said, detecting and quantifying protein phosphorylation has remained a challenge. We describe the use of a novel mass spectrometer (Orbitrap Astral) coupled with data-independent acquisition (DIA) to achieve rapid and deep analysis of human and mouse phosphoproteomes. With this method we map approximately 30,000 unique human phosphorylation sites within a half-hour of data collection. The technology was benchmarked to other state-of-the-art MS platforms using both synthetic peptide standards and with EGF-stimulated HeLa cells. We applied this approach to generate a phosphoproteome multi-tissue atlas of the mouse. Altogether, we detected 81,120 unique phosphorylation sites within 12 hours of measurement. With this unique dataset, we examine the sequence, structural, and kinase specificity context of protein phosphorylation. Finally, we highlight the discovery potential of this resource with multiple examples of novel phosphorylation events relevant to mitochondrial and brain biology.

systems biology↗

Narrow-window DIA: Ultra-fast quantitative analysis of comprehensive proteomes with high sequencing depth

Mass spectrometry (MS)-based proteomics aims to characterize comprehensive proteomes in a fast and reproducible manner. Here, we present an ultra-fast scanning data-independent acquisition (DIA) strategy consisting on 2-Th precursor isolation windows, dissolving the differences between data-dependent and independent methods. This is achieved by pairing a Quadrupole Orbitrap mass spectrometer with the asymmetric track lossless (Astral) analyzer that provides >200 Hz MS/MS scanning speed, high resolving power and sensitivity, as well as low ppm-mass accuracy. Narrow-window DIA enables profiling of up to 100 full yeast proteomes per day, or [~]10,000 human proteins in half-an-hour. Moreover, multi-shot acquisition of fractionated samples allows comprehensive coverage of human proteomes in [~]3h, showing comparable depth to next-generation RNA sequencing and with 10x higher throughput compared to current state-of-the-art MS. High quantitative precision and accuracy is demonstrated with high peptide coverage in a 3-species proteome mixture, quantifying 14,000+ proteins in a single run in half-an-hour. TeaserAccurate and precise label-free quantification with comprehensive proteome coverage using narrow-window DIA

systems biology↗

Parallelized Acquisition of Orbitrap and Astral Analyzers Enables High-Throughput Quantitative Analysis.

The growing trend towards high-throughput proteomics demands rapid liquid chromatography-mass spectrometry (LC-MS) cycles that limit the available time to gather the large numbers of MS/MS fragmentation spectra required for identification. Orbitrap analyzers scale performance with acquisition time, and necessarily sacrifice sensitivity and resolving power to deliver higher acquisition rates. We developed a new mass spectrometer that combines a mass resolving quadrupole, the Orbitrap and the novel Asymmetric Track Lossless (Astral) analyzer. The new hybrid instrument enables faster acquisition of high-resolution accurate mass (HRAM) MS/MS spectra compared to state-of-the-art mass spectrometers. Accordingly, new proteomics methods were developed that leverage the strengths of each HRAM analyzer, whereby the Orbitrap analyzer performs full scans with high dynamic range and resolution, synchronized with Astral analyzers acquisition of fast and sensitive HRAM MS/MS scans. Substantial improvements are demonstrated over previous methods using current state-of-the-art mass spectrometers. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=100 SRC="FIGDIR/small/543408v1_ufig1.gif" ALT="Figure 1"> View larger version (35K): org.highwire.dtl.DTLVardef@1eedfdeorg.highwire.dtl.DTLVardef@1ab7939org.highwire.dtl.DTLVardef@a3b2f8org.highwire.dtl.DTLVardef@13ac46b_HPS_FORMAT_FIGEXP M_FIG C_FIG

cell biology↗

Evaluating the performance of the Astral mass analyzer for quantitative proteomics using data independent acquisition

We evaluate the quantitative performance of the newly released Asymmetric Track Lossless (Astral) analyzer. Using data independent acquisition, the Thermo Scientific Orbitrap Astral mass spectrometer quantifies 5 times more peptides per unit time than state-of-the-art Thermo Scientific Orbitrap mass spectrometers, which have long been the gold standard for high resolution quantitative proteomics. Our results demonstrate that the Orbitrap Astral mass spectrometer can produce high quality quantitative measurements across a wide dynamic range. We also use a newly developed extra-cellular vesicle enrichment protocol to reach new depths of coverage in the plasma proteome, quantifying over 5,000 plasma proteins in a 60-minute gradient with the Orbitrap Astral mass spectrometer.

biochemistry↗