bioRxiv Science⌕ Search

Biology subjects

Parkkonen, L.

Publications and source records attributed to Parkkonen, L..

21 records · Page 2Linked to original sources

On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers

The spatial resolution of magnetoencephalography (MEG) can be increased from that of conventional SQUID-based systems by employing on-scalp sensor arrays of e.g. optically-pumped magnetometers (OPMs). However, OPMs reach sufficient sensitivity for neuromagnetic measurements only when operated in a very low absolute magnetic field of few nanoteslas or less, usually not reached in a typical magnetically shielded room constructed for SQUID-based MEG. Moreover, field drifts affect the calibration of OPMs. Static and dynamic control of the ambient field is thus necessary for good-quality neuromagnetic measurements with OPMs. Here, we describe an on-scalp MEG system that utilizes OPMs and external compensation coils that provide static and dynamic shielding against ambient fields.\n\nIn a conventional two-layer magnetically shielded room, our coil system reduced the maximum remanent DC-field component within an 8-channel OPM array from 70 to less than 1 nT, enabling the sensors to operate in the sensitive spin exchange relaxation-free regime. When compensating field drifts below 4 Hz, a low-frequency shielding factor of 22 dB was achieved, which reduced the peak-to-peak drift from 1.3 to 0.4 nT and thereby the standard deviation of the sensor calibration from 1.6% to 0.4%. Without band-limiting the field that is compensated, a low-frequency shielding factor of 43 dB was achieved.\n\nWe validated the system by measuring brain responses to electric stimulation of the median nerve. With dynamic shielding and digital interference suppression methods, single-trial somatosensory evoked responses could be detected. Our results advance the deployment of OPM-based on-scalp MEG in lighter magnetic shields.

neuroscience↗

Across-subject offline decoding of motor imagery from MEG and EEG

Long calibration time hinders the feasibility of brain-computer interfaces (BCI). If other subjects data were used for training the classifier, BCI-based neurofeedback practice could start without the initial calibration. Here, we compare methods for inter-subject decoding of left- vs. right-hand motor imagery (MI) from MEG and EEG.\n\nSix methods were tested on data involving MEG and EEG measurements of healthy participants. Only subjects with good within-subject accuracies were selected for inter-subject decoding. Three methods were based on the Common Spatial Patterns (CSP) algorithm, and three others on logistic regression with l1 - or l2,1 -norm regularization. The decoding accuracy was evaluated using 1) MI and 2) passive movements (PM) for training, separately for MEG and EEG.\n\nWhen the classifier was trained by MI, the best accuracies across subjects (mean 70.6% for MEG, 67.7% for EEG) were obtained using multi-task learning (MTL) with logistic regression and l2,1-norm regularization. MEG yielded slightly better average accuracies than EEG. When PM were used for training, none of the inter-subject methods yielded above chance level (58.7%) accuracy.\n\nIn conclusion, MTL and training with other subjects MI is efficient for inter-subject decoding of MI. Passive movements of other subjects are likely suboptimal for training the MI classifiers.

neuroscience↗

Requirements for coregistration accuracy in on-scalp MEG

Recent advances in magnetic sensing has made on-scalp magnetoencephalography (MEG) possible. In particular, optically-pumped magnetometers (OPMs) have reached sensitivity levels that enable their use in MEG. In contrast to the SQUID sensors used in current MEG systems, OPMs do not require cryogenic cooling and can thus be placed within millimetres from the head, enabling the construction of sensor arrays that conform to the shape of an individuals head. To properly estimate the location of neural sources within the brain, one must accurately know the position and orientation of sensors in relation to the head. With the adaptable on-scalp MEG sensor arrays, this coregistration becomes more challenging than in current SQUID-based MEG systems that use rigid sensor arrays.\n\nHere, we used simulations to quantify how accurately one needs to know the position and orientation of sensors in an on-scalp MEG system. The effects that different types of localisation errors have on forward modelling and source estimates obtained by minimum-norm estimation, dipole fitting, and beamforming are detailed.\n\nWe found that sensor position errors generally have a larger effect than orientation errors and that these errors affect the localisation accuracy of superficial sources the most. To obtain similar or higher accuracy than with current SQUID-based MEG systems, RMS sensor position and orientation errors should be < 4 mm and < 10{degrees}, respectively.

neuroscience↗