bioRxiv Science⌕ Search

Biology subjects

Oeltzschner, G.

Publications and source records attributed to Oeltzschner, G..

At least 37 records · Page 2Linked to original sources

The AGNOSTIC MRS Benchmark Dataset: Deep Learning for Out-of-voxel Artifacts

Neural networks are potentially valuable for many of the challenges associated with MRS data. The purpose of this manuscript is to describe the AGNOSTIC dataset, which contains 259,200 synthetic 1H MRS examples for training and testing neural networks. AGNOSTIC was created using 270 basis sets that were simulated across 18 field strengths and 15 echo times. The synthetic examples were produced to resemble in vivo brain data with combinations of metabolite, macromolecule, residual water signals, and noise. To demonstrate the utility, we apply AGNOSTIC to train two Convolutional Neural Networks (CNNs) to address out-of-voxel (OOV) echoes. A Detection Network was trained to identify the point-wise presence of OOV echoes, providing proof of concept for real-time detection. A Prediction Network was trained to reconstruct OOV echoes, allowing subtraction during post-processing. Complex OOV signals were mixed into 85% of synthetic examples to train two separate CNNs for the detection and prediction of OOV signals. AGNOSTIC is available through Dryad and all Python 3 code is available through GitHub. The Detection network was shown to perform well, identifying 95% of OOV echoes. Traditional modeling of these detected OOV signals was evaluated and may prove to be an effective method during linear-combination modeling. The Prediction Network greatly reduces OOV echoes within FIDs and achieved a median log10 normed-MSE of -1.79, an improvement of almost two orders of magnitude.

neuroscience↗

Impact of acquisition and modeling parameters on test-retest reproducibility of edited GABA+

Literature values for within-subject test-retest reproducibility of gamma-aminobutyric acid (GABA), measured with edited magnetic resonance spectroscopy (MRS), vary widely. Reasons for this variation remain unclear. Here we tested whether sequence complexity (two-experiment MEGA-PRESS versus four-experiment HERMES), editing pulse duration (14 versus 20 ms), scanner frequency drift (interleaved water referencing (IWR) turned ON versus OFF), and linear combination modeling variations (three different co-edited macromolecule models and 0.55 versus 0.4 ppm spline baseline knot spacing) affected the within-subject coefficient of variation of GABA + macromolecules (GABA+). We collected edited MRS data from the dorsal anterior cingulate cortex from 20 participants (30.8 {+/-} 9.5 years; 10 males). Test and retest scans were separated by removing the participant from the scanner for 5-10 minutes. Each acquisition consisted of two MEGA-PRESS and two HERMES sequences with editing pulse durations of 14 and 20 ms (referred to here as: MEGA-14, MEGA-20, HERMES-14, and HERMES-20; all TE = 80 ms, 224 averages). Reproducibility did not consistently differ for MEGA-PRESS compared with HERMES or for 14 compared with 20 ms editing pulses. A composite model of the 0.9 and 3 ppm macromolecules (particularly for HERMES) and sparser (0.55 compared with 0.4 ppm) spline baseline knot spacing yielded generally better test-retest reproducibility for GABA+. Replicating our prior results, linear combination modeling in Osprey compared with simple peak fitting in Gannet resulted in substantially better test-retest reproducibility. These results highlight the importance of model selection for edited MRS studies of GABA+, particularly for clinical studies which focus on individual patient differences in GABA+ or changes following an intervention.

neuroscience↗

sLASER and PRESS Perform Similarly at Revealing Metabolite-Age Correlations

PurposeTo compare the respective ability of PRESS and sLASER to reveal biological relationships, using age as a validation covariate. MethodsMRS data were acquired from 102 healthy volunteers using PRESS and sLASER in centrum semiovale (CSO) and posterior cingulate cortex (PCC) regions. Acquisition parameters included TR/TE 2000/30 ms; 96 transients; 2048 datapoints sampled at 2 kHz. Spectra were analyzed using Osprey. Signal-to-noise ratio (SNR), full-width-half-maximum linewidth of tCr, and metabolite concentrations were extracted. A linear model was used to compare SNR and linewidth. Paired t-tests were used to assess differences in metabolite measurements between PRESS and sLASER. Correlations were used to evaluate the relationship between PRESS and sLASER metabolite estimates, as well as the strength of each metabolite-age relationship. Coefficients of variation were calculated to assess inter-subject variability in each metabolite measurement. ResultsSNR and linewidth were significantly higher (p<0.05) for sLASER than PRESS. Paired t-tests showed significant differences between PRESS and sLASER in most metabolite measurements. Metabolite measures were significantly correlated (p<0.05) for most metabolites between the two methods except GABA, Gln and Lac in CSO and GSH, Lac and NAAG in PCC. Metabolite-age relationships were consistently identified using both PRESS and sLASER. Similar CVs were observed for most metabolites. ConclusionThe study results suggest strong agreement between PRESS and sLASER in identifying relationships between brain metabolites and age in CSO and PCC data acquired at 3T. sLASER is technically desirable due to the reduced chemical shift displacement artifact; however, PRESS performed similarly in good brain regions at clinical field strength.

neuroscience↗

Metabolite T1 relaxation times differ across the adult lifespan

PurposeTo investigate the age-dependence of metabolite T1 relaxation times at 3T in both gray- and white-matter-rich voxels. MethodsThis manuscript analyzes publicly available metabolite and metabolite-nulled (single inversion recovery TI = 600 ms) spectra acquired at 3T using PRESS localization. Voxels were placed in posterior cingulate cortex and centrum semiovale in 102 healthy volunteers across 5 decades of life (20s to 60s). All spectra were analyzed in Osprey v2.4.0. To estimate T1 relaxation times for tNAA2.0 and tCr3.0, the ratio of modeled metabolite residual amplitudes in the metabolite-nulled spectrum to the full metabolite signal was calculated using the single inversion recovery signal equation. Correlations between T1 and subject age were evaluated. ResultsSpearman correlations revealed that estimated T1 relaxation times of tNAA2.0 (rs = -0.43; p < 0.001) and tCr3.0 (rs = -0.23; p = 0.021) decreased significantly with age in white-matter-rich CSO, and less steeply (and not significantly) for tNAA2.0 (rs = -0.15; p = 0.136) and tCr3.0 (rs = -0.10; p = 0.319) in gray-matter-rich PCC. ConclusionThe analysis harnessed a large publicly available cross-sectional dataset to test an important hypothesis, that metabolite T1 relaxation times change with age. This preliminary study stresses the importance of further work to measure age-normed metabolite T1 relaxation times for accurate quantification of metabolite levels in studies of aging.

neuroscience↗

Continuous automated MRS data analysis workflow for applied studies

BackgroundMagnetic resonance spectroscopy (MRS) can non-invasively measure levels of endogenous metabolites in living tissue and is of great interest to neuroscience and clinical research. To this day, MRS data analysis workflows differ substantially between groups, frequently requiring many manual steps to be performed on individual datasets, e.g., data renaming/sorting, manual execution of analysis scripts, and manual assessment of success/failure. Manual analysis practices are a substantial barrier to wider uptake of MRS. They also increase the likelihood of human error and prevent deployment of MRS at large scale. Here, we demonstrate an end-to-end workflow for fully automated data uptake, processing, and quality review. New MethodThe proposed continuous automated MRS analysis workflow integrates several recent innovations in MRS data and file storage conventions. They are efficiently deployed by a directory monitoring service that automatically triggers the following steps upon arrival of a new raw MRS dataset in a project folder: (1) conversion from proprietary manufacturer file formats into the universal format NIfTI-MRS; (2) consistent file system organization according to the data accumulation logic standard BIDS-MRS; (3) executing a command-line executable of our open-source end-to-end analysis software Osprey; (4) e-mail delivery of a quality control summary report for all analysis steps. ResultsThe automated architecture successfully completed for a demonstration dataset. The only manual step required was to copy a raw data folder into a monitored directory. Comparison with Existing Method(s)The workflow presented here is the first implementation of a continuous automated MRS analysis ecosystem based on NIfTI-MRS and BIDS-MRS standards. Traditional MRS workflows are non-standardized, often require manual input, and frequently noy compatible with established neuroimaging workflows. This workflow should therefore facilitate integration of MRS into large-scale and multi-center studies. ConclusionsContinuous automated analysis of MRS data can reduce the burden of manual data analysis and quality control, particularly for non-expert users and multi-center or large-scale studies.

neuroscience↗

More than half of the variance in in-vivo 1H-MRS metabolite estimates is common to all metabolites

The present study characterized associations among brain metabolite levels, applying bivariate and multivariate (i.e., factor analysis) statistical methods to tCr-referenced estimates of the major PRESS 1H-MRS metabolites (i.e., tNAA/tCr, tCho/tCr, mI/tCr, Glx/tCr), acquired from medial parietal lobe in a large (n=299), well-characterized international cohort of healthy volunteers (Povazan et al., 2020). Results supported the hypothesis that 1H-MRS-measured metabolite estimates are moderately intercorrelated (Mr = 0.42, SDr = 0.11, ps < 0.001), with more than half (i.e., 57%) of the total variability in metabolite estimates common to (i.e., shared by) all metabolites. Older age was significantly associated with lower levels of common metabolite variance (CMV; {beta} = -0.09, p = 0.048), despite not being associated with levels of any individual metabolite. Holding CMV levels constant, females had significantly lower levels of total choline (i.e., unique metabolite variance or UMV; {beta} = -0.19, p < 0.001), mirroring significant bivariate correlations between sex and total choline reported previously. If replicated, these results would suggest that applied 1H-MRS researchers should shift their analytical framework from examining bivariate associations between individual metabolites and specialty-dependent (e.g., clinical, research) variables of interest (e.g., using t-tests) to examining multi-variable (i.e., covariate) associations between multiple metabolites and specialty-dependent variables of interest (e.g., using multiple regression). Without this shift, clear interpretation of associations of 1H-MRS metabolites with specialty-dependent variables of interest may not be possible.

neuroscience↗

Functional MRS studies of GABA and Glutamate/Glx: a systematic review and meta-analysis

Functional magnetic resonance spectroscopy (fMRS) can be used to investigate neurometabolic responses to external stimuli in-vivo, but findings are inconsistent. We performed a systematic review and meta-analysis on fMRS studies of the primary neurotransmitters Glutamate (Glu), Glx (Glutamate + Glutamine), and GABA. Data were extracted, grouped by metabolite, stimulus domain, and brain region, and analysed by determining standardized effect sizes. The quality of individual studies was rated. When results were analysed by metabolite type small to moderate effect sizes of 0.29-0.47 (p < 0.05) were observed for changes in Glu and Glx regardless of stimulus domain and brain region, but no significant effects were observed for GABA. Further analysis suggests that Glu, Glx and GABA responses differ by stimulus domain or task and vary depending on the time course of stimulation and data acquisition. Here, we establish effect sizes and directionality of GABA, Glu and Glx response in fMRS. This work highlights the importance of standardised reporting and minimal best practice for fMRS research.

neuroscience↗

Cohort-mean measured macromolecules lead to more robust linear-combination modeling than subject-specific or parameterized ones

Expert consensus recommends linear-combination modeling (LCM) of 1H MR spectra with sequence-specific simulated metabolite basis function and experimentally derived macromolecular (MM) basis functions. Measured MM basis functions have been derived from metabolite-nulled spectra averaged across a small cohort. The use of subject-specific instead of cohort-averaged measured MM basis functions has not been studied. Furthermore, measured MM basis functions are not widely available to non-expert users, who commonly rely on parameterized MM signals internally simulated by LCM software. To investigate the impact of the choice of MM modeling, this study, therefore, compares metabolite level estimates between different MM modeling strategies (cohort-mean measured; subject-specific measured; parameterized) in a lifespan cohort and characterizes its impact on metabolite-age associations. 100 conventional (TE = 30 ms) and metabolite-nulled (TI = 650 ms) PRESS datasets, acquired from the medial parietal lobe in a lifespan cohort (20-70 years of age), were analyzed in Osprey. Short-TE spectra were modeled in Osprey using six different strategies to consider the macromolecular baseline. Fully tissue- and relaxation-corrected metabolite levels were compared between MM strategies. Model performance was evaluated by model residuals, the Akaike information criterion (AIC), and the impact on metabolite-age associations. The choice of MM strategy had a significant impact on the mean metabolite level estimates and no major impact on variance. Correlation analysis revealed moderate-to-strong agreement between different MM strategies (r > 0.6). The lowest relative model residuals and AIC values were found for the cohort-mean measured MM. Metabolite-age associations were consistently found for two major singlet signals (tCr, tCho) for all MM strategies, however, findings for highly J-coupled metabolites it was depended on the MM strategy. A variance partition analysis indicated that up to 44% of the total variance was related to the choice of MM strategy. Additionally, the variance partition analysis reproduced the metabolite-age association for tCr and tCho found in the simpler correlation analysis. In summary, the inclusion of a single high-SNR MM basis function (cohort-mean) leads to more robust metabolite estimation (lower model residuals and AIC values) compared to MM strategies with more degrees of freedom (Gaussian parametrization) or subject-specific MM information. Integration of multiple LCM analyses into a single statistical model potentially improves the robustness in the detection of underlying effects (e.g. metabolite vs age), reduces algorithm-based bias, and estimates algorithm-related variance.

neuroscience↗

Impact of gradient scheme and shimming on out-of-voxel echo artifacts in edited MRS

Out-of-voxel (OOV) signals are common spurious echo artifacts in magnetic resonance spectroscopy (MRS). These signals often manifest in the spectrum as very strong ripples which interfere with spectral quantification by overlapping with targeted metabolite resonances. Dephasing Optimization Through Coherence Order Pathway Selection (DOTCOPS) gradient schemes are algorithmically optimized to suppress all potential alternative coherence transfer pathways (CTPs), and should suppress unwanted OOV echoes. In addition, second-order shimming uses non-linear gradient fields to maximize field homogeneity inside the voxel, which unfortunately increases the diversity of local gradient fields outside of the voxel. Given that strong local spatial B0 gradients can refocus unintended CTPs, it is possible that OOVs are less prevalent when only linear first-order shimming is applied. Here we compare the size of unwanted OOV signals in Hadamard-edited (HERMES) data acquired with either a local gradient scheme (which we refer to here as "Shared") or DOTCOPS, and with first or second-order shimming. We collected data from 15 healthy volunteers in two brain regions (voxel size 30x26x26mm3) from which it is challenging to acquire MRS data: medial prefrontal cortex (MPFC) and left temporal cortex (LTC). Characteristic OOV echoes were seen in both GABA- and GSH-edited spectra for both brain regions, gradient schemes, and shimming approaches. A linear mixed-effect (LME) model revealed a statistically significant difference in the average residual based on gradient scheme in both GABA-(p < 0.001) and GSH-edited (p < 0.001) spectra; that is, the DOTCOPS gradient scheme resulted in smaller OOV artifacts compared with the Shared scheme. There were no significant differences in OOV artifacts associated with shimming method. Thus, these results suggest that the DOTCOPS gradient scheme for J-difference-edited PRESS acquisitions yields spectra with smaller OOV echo artifacts than the Shared gradient scheme implemented in a widely disseminated editing sequence.

biophysics↗

Neurometabolic timecourse of healthy aging

PurposeThe neurometabolic timecourse of healthy aging is not well-established, in part due to diversity of quantification methodology. In this study, a large structured cross-sectional cohort of male and female subjects throughout adulthood was recruited to investigate neurometabolic changes as a function of age, using consensus-recommended magnetic resonance spectroscopy quantification methods. Methods102 healthy volunteers, with approximately equal numbers of male and female participants in each decade of age from the 20s, 30s, 40s, 50s, and 60s, were recruited with IRB approval. MR spectroscopic data were acquired on a 3T MRI scanner. Metabolite spectra were acquired using PRESS localization (TE = 30 ms; 96 transients) in the centrum semiovale (CSO) and posterior cingulate cortex (PCC). Water-suppressed spectra were modeled using the Osprey algorithm, employing a basis set of 18 simulated metabolite basis functions and a cohort-mean measured macromolecular spectrum. Pearson correlations were conducted to assess relationships between metabolite concentrations and age for each voxel; paired t-tests were run to determine whether metabolite concentrations differed between the PCC and CSO. ResultsTwo datasets were excluded (1 ethanol; 1 unacceptably large lipid signal). Statistically significant age-by-metabolite correlations were seen for tCr (R2=0.36; p<0.001), tCho (R2=0.11; p<0.001), sI (R2=0.11; p=0.004), and mI (R2=0.10; p<0.001) in the CSO, and tCr (R2=0.15; p<0.001), tCho (R2=0.11; p<0.001), and GABA (R2=0.11; p=0.003) in the PCC. No significant correlations were seen between tNAA, NAA, GSH, Glx or Glu and age in either region (all p>0.25). Levels of sI were significantly higher in the PCC in female subjects (p<0.001) than in male subjects. There was a significant positive correlation between linewidth and age. ConclusionThe results indicated age correlations for tCho, tCr, sI, and mI in CSO and for tCr, tCho and GABA in PCC, while no age-related changes were found for NAA, tNAA, GSH, Glu or Glx. Our results provide a normative foundation for future work investigating the neurometabolic time course of healthy aging using MRS. HighlightsO_LIA large structured cross-sectional cohort of neurometabolic aging dataset is presented; C_LIO_LIAge correlations were observed for tCho, tCr, sI, and mI in CSO and for tCr, tCho and GABA in PCC; C_LIO_LINo age correlations were found for NAA, tNAA, GSH, Glu or Glx in either region. C_LI

neuroscience↗

The Value of Zero-filling in In Vivo MRS

Two opinions currently exist on the role of zero-filling in data processing for in vivo MRS: that it results in a purely cosmetic interpolation; or that it confers a benefit. Most commonly, in vivo MRS data are acquired as complex time-domain half-echoes, that are Fourier transformed to the give a real spectrum that is modeled for quantification. In this manuscript, we highlight that performing zero-filling draws the independent information from the imaginary part of the spectrum into the real spectrum, improving modeling accuracy. In order to demonstrate this, 10,000 time-domain datasets were simulated as decaying exponentials and noise was added. Data were then Fourier transformed with no-zero filling, 2x, 4x and 8x zero-filling. All spectra were then modeled using a simple single-Lorentzian frequency-domain model. It was demonstrated that 2x zero-filling results in a [~]{surd}2 benefit in modeling accuracy, compared to no zero-filling. There was no additional advantage for further zero-filling.

neuroscience↗

MRSCloud: a Cloud-based MR Spectroscopy Tool for Basis Set Simulation

BackgroundAccurate quantification of in vivo proton magnetic resonance spectra involves modeling with a linear combination of known metabolite basis functions. Basis sets can be generated by numerical simulation using the quantum mechanical density-matrix formalism. Accurate simulations for a basis set require correct sequence timings, and pulse shapes and durations. PurposeTo present a cloud-based spectral simulation tool MRSCloud. It allows community users of MRS to simulate a vendor- and sequence-specific basis set online in a convenient and timeefficient manner. This tool can simulate basis sets for 3 major MR scanner vendors (GE, Philips, Siemens), including conventional acquisitions and spectral editing schemes (MEGA, HERMES, HERCULES) with PRESS and semi-LASER localization. Study TypeProspective. SpecimenN/A Field Strength/SequenceSimulations of 3T basis sets for conventional and spectral-editing sequences (MEGA, HERMES, HERCULES) with PRESS and sLASER localizations. AssessmentSimulated metabolite basis functions generated by MRSCloud are compared to those generated by FID-A and MARSS, and a phantom-acquired basis-set from LCModel. Statistical TestsIntraclass correlation coefficients (ICC) were calculated to measure the agreement between individual metabolite basis functions generated using different packages. Statistical analysis was performed using R in RStudio. ResultsSimulation time for a full basis set is approximately 1 hour. ICCs between MRSCloud and FID-A were at least 0.98 and ICCs between MRSCloud and MARSS were at least 0.96. ICCs between simulated MRSCloud basis spectra and acquired LCModel basis spectra were lowest for Gln at 0.68 and highest for NAA at 0.96. Data ConclusionSubstantial reductions in runtime have been achieved by implementing the 1D projection method, coherence-order filtering, and pre-calculation of propagators. High ICC values indicated that the accelerating features are running correctly and produce comparable and accurate basis sets. The generated basis set has been successfully used with LCModel.

bioengineering↗

Importance of linear combination modeling for quantification of Glutathione and GABA levels using Hadamard-edited MRS

PurposeTwo main approaches are used for spectral analysis of edited data: simple peak fitting and linear combination modeling (LCM) with a simulated basis set. Recent consensus recommended LCM as the method of choice for the spectral analysis of edited data. The aim of this study is to compare the performance of simple peak fitting and LCM in a test-retest dataset, hypothesizing that the more sophisticated LCM approach will improve quantification of HERMES data compared with simple peak fitting. MethodsA test-retest dataset was re-analyzed using Gannet (simple peak fitting) and Osprey (LCM). These data were obtained from the dorsal anterior cingulate cortex of twelve healthy volunteers, with TE 80 ms for HERMES and TE 120 ms for MEGA-PRESS of glutathione (GSH). Within-subject coefficients of variance (CVs) were calculated to quantify between-scan reproducibility of each metabolite estimate. ResultsThe reproducibility of HERMES GSH estimates was substantially improved using LCM compared to simple peak fitting, from a CV of 19.0% to 9.9%. For MEGA-PRESS data, the GSH reproducibility was similar using LCM and simple peak fitting, with CVs of 7.3% and 8.8% respectively. ConclusionLinear combination modeling with simulated basis functions substantially improves the reproducibility of GSH quantification for HERMES data.

biophysics↗

Comparison of seven modelling algorithms for GABA-edited 1H-MRS

Edited MRS sequences are widely used for studying GABA in the human brain. Several algorithms are available for modelling these data, deriving metabolite concentration estimates through peak fitting or a linear combination of basis spectra. The present study compares seven such algorithms, using data obtained in a large multi-site study. GABA-edited (GABA+, TE = 68 ms MEGA-PRESS) data from 222 subjects at 20 sites were processed via a standardised pipeline, before modelling with FSL-MRS, Gannet, AMARES, QUEST, LCModel, Osprey and Tarquin, using standardised vendor-specific basis sets (for GE, Philips and Siemens) where appropriate. After referencing metabolite estimates (to water or creatine), systematic differences in scale were observed between datasets acquired on different vendors hardware, presenting across algorithms. Scale differences across algorithms were also observed. Using the correlation between metabolite estimates and voxel tissue fraction as a benchmark, most algorithms were found to be similarly effective in detecting differences in GABA+. An inter-class correlation across all algorithms showed single-rater consistency for GABA+ estimates of around 0.38, indicating moderate agreement. Upon inclusion of a basis set component explicitly modelling the macromolecule signal underlying the observed 3.0 ppm GABA peaks, single-rater consistency improved to 0.44. Correlation between discrete pairs of algorithms varied, and was concerningly weak in some cases. Our findings highlight the need for consensus on appropriate modelling parameters across different algorithms, and for detailed reporting of the parameters adopted in individual studies to ensure reproducibility and meaningful comparison of outcomes between different studies. HighlightsO_LIGABA-edited MRS data from 222 healthy adults across 20 research sites were analyzed C_LIO_LIData were modelled using seven different algorithms, yielding GABA+ and Glx estimates C_LIO_LIModerate agreement was seen across all the tested algorithms C_LIO_LIAdding a component to represent co-edited macromolecule signals improved concordance C_LIO_LIBaseline modelling emerged as major factor differentiating outcomes C_LI

neuroscience↗

NIfTI-MRS: A standard format for magnetic resonance spectroscopic data

PurposeThe use of multiple data formats in the MRS community currently hinders data sharing and integration. NIfTI-MRS is proposed as a standard MR spectroscopy data format, which is implemented as an extension to the neuroimaging informatics technology initiative (NIfTI) format. Using this standardised format will facilitate data sharing, ease algorithm development, and encourage the integration of MRS analysis with other imaging modalities. MethodsA file format based on the NIfTI header extension framework was designed to incorporate essential spectroscopic metadata and additional encoding dimensions. A detailed description of the specification is provided. An open-source command-line conversion program is implemented to enable conversion of single-voxel and spectroscopic imaging data to NIfTI-MRS. To provide visualisation of data in NIfTI-MRS, a dedicated plugin is implemented for FSLeyes, the FSL image viewer. ResultsAlongside online documentation, ten example datasets are provided in the proposed format. In addition, minimal examples of NIfTI-MRS readers have been implemented. The conversion software, spec2nii, currently converts fourteen formats to NIfTI-MRS, including DICOM and vendor proprietary formats. ConclusionThe proposed format aims to solve the issue of multiple data formats being used in the MRS community. By providing a single conversion point, it aims to simplify the processing and analysis of MRS data, thereby lowering the barrier to use of MRS. Furthermore, it can serve as the basis for open data sharing, collaboration, and interoperability of analysis programs. It also opens possibility of greater standardisation and harmonisation. By aligning with the dominant format in neuroimaging, NIfTI-MRS enables the use of mature tools present in the imaging community, demonstrated in this work by using a dedicated imaging tool, FSLeyes, as a viewer.

neuroscience↗

The Macromolecular MR Spectrum in Healthy Aging

PurposeMobile macromolecules (MMs) from amino acids, cytosolic proteins and mobile lipids contribute a significant spectral background underlying the metabolite signals in the MR spectrum. A recent consensus recommends that MM contributions should be removed or included in modeling basis sets for determination of metabolite concentrations and/or metabolite ratios. The purpose of this study was to acquire the MM spectrum from healthy participants at a range of ages, and to investigate changes in the signals with age and sex groups. MethodsInversion time (TI) series were acquired to determine an optimal inversion time to null the metabolite signals. Experiments were carried out using a single adiabatic hyperbolic-secant inversion pulse. After the preliminary experiment, 102 volunteers (49M/53F) between 20 and 69 years were recruited for in vivo data acquisition in the centrum semiovale (CSO) and posterior cingulate cortex (PCC). The protocol consisted of a T1-weighted MPRAGE for structural images, followed by PRESS localization using a voxel size of 30 x 26 x 26 mm3 with pre-inversion (TR/TI 2000/600 ms) and CHESS water suppression. Metabolite-nulled spectra were modeled using a reduced basis set (NAA, Cr, Cho, Glu) and a flexible spline baseline (0.1 ppm knot spacing) followed by subtraction of the modeled metabolite signals to yield a clean MM spectrum, using the Osprey software. Pearsons correlation coefficient was calculated between integrals and age for the 14 MM signals between 0.9-4.2 ppm. One-way ANOVA was performed to determine differences between age groups. An independent t-test was carried out to determine differences between sexes. Relationships between brain tissues with age and sex groups were also measured. ResultsMM spectra were successfully acquired in 99 (CSO) and 96 (PCC) of 102 subjects. No significant correlations were seen between age and MM integrals. One-way ANOVA also suggested no age-group differences for any MM peak (all p > 0.004). No differences were observed between sex groups. The voxels were segmented as 80 {+/-} 4% white matter, 18 {+/-} 4% gray matter, and 2 {+/-} 1% CSF for CSO and 28 {+/-} 4% white matter, 61 {+/-} 4% gray matter and 11 {+/-} 1% CSF for PCC. WM and GM showed a significant (p < 0.05) negative linear association with age in the WM-predominant CSO (R = -0.29) and GM-predominant PCC regions (R = -0.57) respectively while CSF increased significantly with age in both regions. ConclusionOur findings indicate that the MM spectrum is stable across a large age range and between sexes, suggesting a pre-defined MM basis function can be used for linear combination modeling of metabolite data from different age and sex groups. HighlightsO_LIA large publicly available MM-aging dataset is presented. C_LIO_LIMacromolecule signals do not change with age between 20 and 70. C_LIO_LIThere is no sex difference for macromolecule integrals. C_LI

bioengineering↗

Comparison of linear combination modeling strategies for GABA-edited MRS at 3T

PurposeJ-difference-edited spectroscopy is a valuable approach for the in vivo detection of {gamma}-aminobutyric-acid (GABA) with MRS. A recent expert consensus article recommends linear combination modeling (LCM) of edited MRS but does not give specific details of implementation. This study explores different modeling strategies to adapt LCM for GABA-edited MRS. Methods61 medial parietal lobe GABA-edited MEGA-PRESS spectra from a recent 3T multi-site study were modeled using 102 different strategies combining six different approaches to account for co-edited macromolecules, three modeling ranges, three baseline knot spacings, and the use of basis sets with or without homocarnosine. The resulting GABA and GABA+ estimates (quantified relative to total creatine), the residuals at different ranges, SDs and CVs, and Akaike information criteria, were used to evaluate the models performance. ResultsSignificantly different GABA+ and GABA estimates were found when a well-parameterized MM3co basis function was included in the model. The mean GABA estimates were significantly lower when modeling MM, while the CVs were similar. A sparser spline knot spacing led to lower variation in the GABA and GABA+ estimates, and a narrower modeling range - only including the signals of interest - did not substantially improve or degrade modeling performance. Additionally, results suggest that LCM can separate GABA and the underlying co-edited MM3co. Incorporating homocarnosine into the modeling did not significantly improve variance in GABA+ estimates. ConclusionGABA-edited MRS is most appropriately quantified by LCM with a well-parameterized co-edited MM3co basis function with a constraint to the non-overlapped MM0.93, in combination with a sparse spline knot spacing (0.55 ppm) and a modeling range between 0.5 and 4 ppm. Graphical Abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=76 SRC="FIGDIR/small/445817v3_ufig1.gif" ALT="Figure 1"> View larger version (19K): org.highwire.dtl.DTLVardef@129ce60org.highwire.dtl.DTLVardef@1ac3797org.highwire.dtl.DTLVardef@1759d69org.highwire.dtl.DTLVardef@b190a3_HPS_FORMAT_FIGEXP M_FIG C_FIG 102 strategies to model GABA-edited MRS with linear combination modeling were evaluated to quantify GABA and GABA+ in Osprey. Significantly different GABA and GABA+ estimates were found when a well-parameterized macro-molecule at 3 ppm was included. The findings suggest that linear combination modeling needs to be adapted for quantification of GABA-edited MRS.

biochemistry↗

Comparison of algorithms for linear-combination modelling of short-echo-time magnetic resonance spectra

Short-TE proton MRS is used to study metabolism in the human brain. Common analysis methods model the data as linear combination of metabolite basis spectra. This large-scale multi-site study compares the levels of the four major metabolite complexes in short-TE spectra estimated by three linear-combination modelling (LCM) algorithms. 277 medial parietal lobe short-TE PRESS spectra (TE = 35 ms) from a recent 3T multi-site study were pre-processed with the Osprey software. The resulting spectra were modelled with Osprey, Tarquin and LCModel, using the same three vendor-specific basis sets (GE, Philips, and Siemens) for each algorithm. Levels of total N-acetylaspartate (tNAA), total choline (tCho), myoinositol (mI), and glutamate+glutamine (Glx) were quantified with respect to total creatine (tCr). Group means and CVs of metabolite estimates agreed well for tNAA and tCho across vendors and algorithms, but substantially less so for Glx and mI, with mI systematically estimated lower by Tarquin. The cohort mean coefficient of determination for all pairs of LCM algorithms across all datasets and metabolites was [Formula], indicating generally only moderate agreement of individual metabolite estimates between algorithms. There was a significant correlation between local baseline amplitude and metabolite estimates (cohort mean [Formula]). While mean estimates of major metabolite complexes broadly agree between linear-combination modelling algorithms at group level, correlations between algorithms are only weak-to-moderate, despite standardized pre-processing, a large sample of young, healthy and cooperative subjects, and high spectral quality. These findings raise concerns about the comparability of MRS studies, which typically use one LCM software and much smaller sample sizes. Graphical Abstract O_TBL View this table: org.highwire.dtl.DTLVardef@6775bdorg.highwire.dtl.DTLVardef@62f27borg.highwire.dtl.DTLVardef@1d77ccorg.highwire.dtl.DTLVardef@a4049aorg.highwire.dtl.DTLVardef@2a1feb_HPS_FORMAT_FIGEXP M_TBL C_TBL Three linear-combination algorithms (Osprey, Tarquin and LCMode) were used to quantify the levels of tNAA, tCho, mI, and Glx in 277 short-TE PRESS. Group means and CVs of metabolite estimates agreed well for tNAA and tCho, but substantially less so for Glx and mI with a cohort mean correlation coefficient of [Formula], indicating moderate agreement between algorithms. These findings raise concerns about the comparability of MRS studies, which typically use one LCM software and much smaller sample sizes.

biochemistry↗