bioRxiv Science⌕ Search

Biology subjects

Nunez Ponasso, G. C.

Publications and source records attributed to Nunez Ponasso, G. C..

7 recordsLinked to original sources

Low Intensity Multi-Channel Steering TMS Array for Network Level Neuromodulation

Objective: Low-intensity transcranial magnetic stimulation (LI-TMS) is being investigated as a gel-free alternative to transcranial electrical stimulation (tES), but existing systems remain almost exclusively single-channel and cannot electronically steer the induced electric field. We present the design, modeling, and experimental measurement of a wearable whole-head, multichannel, steerable LI-TMS array. Methods: The system comprises a 102-channel conformal coil array with independently controlled drivers capable of arbitrary waveform synthesis, together with a boundary element fast multipole method (BEM-FMM) framework that computes the coil currents required to produce prescribed cortical field patterns. A 12-channel prototype was characterized by coil-current, electric-field, and thermal measurements. Results: The prototype produced a peak primary electric field of approximately 1 V/m measured in air 4 cm from the inner helmet surface. Whole-array modeling attained cortical fields of up to 1.5 V/m, reproduced the field distribution of a clinically validated low-intensity stimulator to within 3%-5%, and demonstrated focal targeting of the dorsolateral prefrontal cortex, simultaneous delivery of electric field to the default mode network nodes, and synthesis of electric fields following the traveling alpha wave. Conclusion: Electronically steerable, whole-head LI-TMS is feasible using accessible microprocessor-controlled power electronics. Significance: The array reaches the cortical field regime of tES without scalp contact or the associated shunting of current through the scalp, offering a route to testing network-level, phaselocked weak-field neuromodulation.

bioengineering↗

Self-powered electronics-free Wearable Disposable Electrotherapy (WDE) platform for accelerated wound healing

Electrical stimulation accelerates wound repair by modulating endogenous bioelectric signals that regulate inflammation, angiogenesis, extracellular matrix remodeling, and cellular responses within the wound microenvironment. However, clinical translation has been hindered by cumbersome devices with procedures that disrupt standard wound-care workflows, direct electrode contact with the wound bed, and/or limited stimulation output. Wearable Disposable Electrotherapy (WDE) integrates an electronics-free printed electrochemical architecture into an mm-thick patch that looks and is applied like a conventional bandage. The device is self- powered and delivers a single electrotherapy dose simply by application to the skin. Device dose-control (electrochemical performance) and efficacy were evaluated in a full-thickness excisional wound model in rats, compared with a sham device and a conventional Constant Current (CC) stimulator. WDE or control treatments were applied daily from day 1 through day 13, with endpoint evaluation on day 14. WDE delivered electrical stimulation comparable to CC while reducing the time required to achieve 50% wound closure by 2.08 days ([~]29%) relative to sham treatment. Histological and immunofluorescence analyses at day 14 demonstrated enhanced tissue remodeling, including increased collagen deposition ([~]25%), tissue cellularity ([~]73%), myofibroblast-associated SMA expression ([~]2.6-fold), angiogenesis-associated CD31 expression ([~]2.0-fold), and increased expression of both M2- (CD206, [~]2.0-fold) and M1- associated (iNOS, [~]1.7-fold) markers compared with sham. A novel cellular-resolution dosimetry model, leveraging charge-based boundary element method accelerated with the fast multipole method (BEM-FMM), provides a biophysical framework linking electrical stimulation with wound microenvironment and tissue repair mechanisms. Together, these findings establish WDE as a practical bioelectric wound dressing that accelerates wound healing and tissue remodeling, with the simplicity and scalability of disposable bandages.

bioengineering↗

Direct Reconstruction of DC Cortical Conductivity from Large-Scale Electron Microscopy Data

Electrical conductivity of cortical gray matter governs the magnitude and spatial distribution of electric fields generated by brain stimulation and intrinsic neuronal activity measured with M/EEG and intracortical recordings. However, reported macroscopic conductivity values vary by more than threefold, limiting the fidelity of bioelectromagnetic models and leaving unresolved whether this variability reflects measurement uncertainty or genuine structural heterogeneity of cortical tissue. Here, we present a multiscale computational framework that, for the first time, attempts to derive mesoscale conductivity maps of mouse visual cortex at 50-{micro}m resolution directly from large-volume, segmented nanometer-scale electron microscopy data. The Minnie 65 subvolume of the MICrONS dataset is accurately subdivided into 1,224 50-{micro}m cubic blocks. Each block contains, on average, 40-50 million membrane facets of a highly convoluted and dense cellular structure. Three orthogonal electrode pairs are applied to each isolated block to estimate the three principal components of the conductivity tensor. Quasistatic electric modeling is enabled by an iterative boundary-element fast multipole method (BEM-FMM) under the approximation of non-conducting membranes (DC conductivity). Spatially averaged conductivity values predicted by our framework agree well with prior low-resolution measurements in rats, validating the approach. At the same time, the resulting mesoscale maps reveal pronounced conductivity granularity at 50-100 {micro}m scales as well as significant variations in both radial and tangential directions. These results indicate that mesoscale conductivity heterogeneity could be an intrinsic structural property of the cortex. Limitations and extensions of this study are discussed in detail.

neuroscience↗

Improved Source Localization of Auditory Evoked Fields using Reciprocal BEM-FMM

The precise localization of auditory evoked fields (AEFs) from magnetoencephalography (MEG) data is very important for the functional understanding of the auditory cortex in medicine and cognitive neuroscience. The numerical solution of the field equations in the human head using the boundary element method (BEM) is a powerful tool for achieving this. We hypothesized that the spatial resolution of the BEM is crucial for the achievable accuracy. However, in classical BEM (as implemented, e.g., in MNE-Python), very high resolutions are impractical due to the associated prohibitive computational effort. In contrast, our recently introduced reciprocal boundary element fast multipole method (reciprocal BEM-FMM) allows for hitherto unprecedented spatial resolution. In this work, we apply our reciprocal BEM-FMM technique for source estimation to localize AEFs, and we compare our results with the source estimates produced using a 3-layer BEM model (standard BEM) via MNE-Python. We first validate our methodology through comparison of source estimates of simulated N1m components of AEFs using a receiver operating characteristic (ROC) measure. While we obtain ROC measures of about 80% for the standard BEM, reciprocal BEM-FMM reaches about 90%, a significant statistical improvement. We then apply this methodology to analyze the source estimates of experimental data obtained from a cohort of 7 participants subjected to binaural auditory stimulation. Using a dispersion measurement to quantify the focality of localized sources, we find improvements upwards of 30% using reciprocal BEM-FMM over the standard BEM. Analyses from both simulated and experimental data show localization of AEFs using high-resolution reciprocal BEM-FMM is significantly better in terms of accuracy and focality than those estimates of the low-resolution standard BEM. We therefore recommend using the high-resolution reciprocal BEM-FMM to utilize high spatial anatomical precision for the modeling of neural activity.

neuroscience↗

Fast and Accurate EEG/MEG BEM-Based Forward Problem Solution for High-Resolution Head Models

A BEM (boundary element method) based approach is developed to accurately solve an EEG/MEG forward problem for a modern high-resolution head model in approximately 60 seconds using a common workstation. The method utilizes a charge-based BEM with fast multipole acceleration (BEM-FMM) and a "smart" mesh pre-refinement (called b-refinement) close to the singular source(s). No costly matrix-filling or direct solution steps typical for the standard BEM are required; the method generates on-skin voltages as well as MEG magnetic fields for high-resolution head models in approximately 60 seconds after initial model assembly. The method is verified both theoretically and experimentally.

neuroscience↗

Accuracy of dipole source reconstruction in the 3-layerBEM model against the 5-layer BEM-FMM model

ObjectiveTo compare cortical dipole fitting spatial accuracy between the widely used yet highly simplified 3-layer and modern more realistic 5-layer BEM-FMM models with and without adaptive mesh refinement (AMR) methods. MethodsWe generate simulated noiseless 256-channel EEG data from 5-layer (7-compartment) meshes of 15 subjects from the Connectome Young Adult dataset. For each subject, we test four dipole positions, three sets of conductivity values, and two types of head segmentation. We use the boundary element method (BEM) with fast multipole method (FMM) acceleration, with or without (AMR), for forward modeling. Dipole fitting is carried out with the FieldTrip MATLAB toolbox. ResultsThe average position error (across all tested dipoles, subjects, and models) is [~]4 mm, with a standard deviation of [~]2 mm. The orientation error is [~]20{degrees} on average, with a standard deviation of [~]15{degrees}. Without AMR, the numerical inaccuracies produce a larger disagreement between the 3- and 5-layer models, with an average position error of [~]8 mm (6 mm standard deviation), and an orientation error of 28{degrees} (28{degrees} standard deviation). ConclusionsThe low-resolution 3-layer models provide excellent accuracy in dipole localization. On the other hand, dipole orientation is retrieved less accurately. Therefore, certain applications may require more realistic models for practical source reconstruction. AMR is a critical component for improving the accuracy of forward EEG computations using a high-resolution 5-layer volume conduction model. SignificanceImproving EEG source reconstruction accuracy is important for several clinical applications, including epilepsy and other seizure-inducing conditions.

bioinformatics↗

Electromagnetic Modeling within a Microscopically Realistic Brain - Implications for Brain Stimulation

Modeling brain stimulation at the microscopic scale may reveal new paradigms for various stimulation modalities. We present the largest map to date of extracellular electric field distributions within a layer L2/L3 mouse primary visual cortex brain sample. This was enabled by the automated analysis of serial section electron microscopy images with improved handling of image defects, covering a volume of 250 x 140 x 90 m3. The map was obtained by applying a uniform brain stimulation electric field at three different polarizations and accurately computing microscopic field perturbations using the boundary element fast multipole method. We used the map to identify the effect of microscopic field perturbations on the activation thresholds of individual neurons. Previous relevant studies modeled a macroscopically homogeneous cortical volume. Our result shows that the microscopic field perturbations - an electric field spatial noise with a mean value of zero - only modestly influence the macroscopically predicted stimulation field strengths necessary for neuronal activation. The thresholds do not change by more than 10% on average. Under the stated limitations and assumptions of our method, this result justifies the conventional theory of "invisible" neurons embedded in a macroscopic brain model for transcranial magnetic and transcranial electrical stimulation. However, our result is solely sample-specific and largely neglects the effect of the microcapillary network. Furthermore, we only considered the uniform impressed field and a single- pulse stimulation time course. Significance statementThis study is arguably the first attempt to model brain stimulation at the microscopic scale, enabled by automated analysis of modern scanning electron microscopy images of the brain. It concentrates on modeling microscopic perturbations of the extracellular electric field caused by the physical cell structure and is applicable to any type of brain stimulation. Data availability statementPost-processed cell CAD models (383, stl format), microcapillary CAD models (34, stl format), post-processed neuron morphologies (267, swc format), extracellular electric field and potential distributions at different polarizations (267x3, MATLAB format), *.ses projects files for biophysical modeling with Neuron software (267x2, Neuron format), and computed neuron activating thresholds at different conditions (267x8, Excel tables, without the sample polarization correction from Section 2.8) are made available online through BossDB, a volumetric open-source database for 3D and 4D neuroscience data.

neuroscience↗