bioRxiv Science⌕ Search

Biology subjects

Novikov, D. S.

Publications and source records attributed to Novikov, D. S..

6 recordsLinked to original sources

In vivo human neurite exchange imaging (NEXI) at 500 mT/m diffusion gradients

Evaluating tissue microstructure and membrane integrity in the living human brain through diffusion-water exchange imaging is challenging due to requirements for a high signal-to-noise ratio and short diffusion times dictated by relatively fast exchange processes. The goal of this work was to demonstrate the feasibility of in vivo imaging of tissue micro-geometries and water exchange within the brain gray matter using the state-of-the-art Connectome 2.0 scanner equipped with an ultra-high-performance gradient system (maximum gradient strength=500 mT/m, maximum slew rate=600 T/m/s). We performed diffusion MRI measurements in 15 healthy volunteers at multiple diffusion times (13-30 ms) and b-values up to 17.5 ms/m2. The anisotropic Karger model was applied to estimate the exchange time between intra-neurite and extracellular water in gray matter. The estimated exchange time across the cortical ribbon was around (median{+/-}interquartile range) 13{+/-}8 ms on Connectome 2.0, substantially faster than that measured using an imaging protocol compatible with Connectome 1.0-alike systems on the same cohort. Our investigation suggested that the NEXI exchange time estimation using a Connectome 1.0 compatible protocol was more prone to residual noise floor biases due to the small time-dependent signal contrasts across diffusion times when the exchange is fast ([≤]20 ms). Furthermore, spatial variation of exchange time was observed across the cortex, where the motor cortex, somatosensory cortex and visual cortex exhibit longer exchange times compared to other cortical regions. Non-linear fitting for the anisotropic Karger model was accelerated 100 times using a GPU-based pipeline compared to the conventional CPU-based approach. This study highlighted the importance of the chosen diffusion times and measures to address Rician noise in dMRI data, which can have a substantial impact on the estimated NEXI exchange time and require extra attention when comparing NEXI results between various hardware setups. Highlights- The Connectome 2.0 scanner equipped with 500 mT/m gradients enables high-sensitivity diffusion MRI for imaging exchange times in vivo - The global exchange time across the living human cortex was estimated to be about 13 ms on Connectome 2.0, faster than measured using a protocol compatible to Connectome 1.0 - Spatially varying exchange times were observed across the cortex - A GPU-accelerated tool was developed to speed up parameter estimation by 100 times - The narrow pulse approximation used in neurite exchange imaging does not affect estimation performance in high gradient performance MRI systems

neuroscience↗

In vivo Mapping of Cellular Resolution Neuropathology in Brain Ischemia by Diffusion MRI

Non-invasive mapping of cellular pathology can provide critical diagnostic and prognostic information. Recent developments in diffusion MRI have produced new tools for examining tissue microstructure at a level well below the imaging resolution. Here, we report the use of diffusion time (t)-dependent diffusion kurtosis imaging (tDKI) to simultaneously assess the morphology and transmembrane permeability of cells and their processes in the context of pathological changes in hypoxic-ischemic brain (HI) injury. Through Monte Carlo simulations and cell culture organoid imaging, we demonstrate feasibility in measuring effective size and permeability changes based on the peak and tail of tDKI curves. In a mouse model of HI, in vivo imaging at 11.7T detects a marked shift of the tDKI peak to longer t in brain edema, suggesting swelling and beading associated with the astrocytic processes and neuronal neurites. Furthermore, we observed a faster decrease of the tDKI tail in injured brain regions, reflecting increased membrane permeability that was associated with upregulated water exchange upon astrocyte activation at acute stage as well as necrosis with disrupted membrane integrity at subacute stage. Such information, unavailable with conventional diffusion MRI at a single t, can predict salvageable tissues. For a proof-of-concept, tDKI at 3T on an ischemic stroke patient suggested increased membrane permeability in the stroke region. This work therefore demonstrates the potential of tDKI for in vivo detection of the pathological changes in microstructural morphology and transmembrane permeability after ischemic injury using a clinically translatable protocol.

bioengineering↗

The influence of axonal beading and undulation on axonal diameter mapping

We consider the effect of non-cylindrical axonal shape on axonal diameter mapping with diffusion MRI. Practical sensitivity to axon diameter is attained at strong diffusion weightings b, where the deviation from the [Formula] scaling yields the finite transverse diffusivity, which is then translated into axon diameter. While axons are usually modeled as perfectly straight, impermeable cylinders, the local variations in diameter (caliber variation or beading) and direction (undulation) have been observed in microscopy data of human axons. Here we quantify the influence of cellular-level features such as caliber variation and undulation on axon diameter estimation. For that, we simulate the diffusion MRI signal in realistic axons segmented from 3-dimensional electron microscopy of a human brain sample. We then create artificial fibers with the same features and tune the amplitude of their caliber variations and undulations. Numerical simulations of diffusion in fibers with such tunable features show that caliber variations and undulations result in under- and over-estimation of axon diameters, correspondingly; this bias can be as large as 100%. Given that increased axonal beading and undulations have been observed in pathological tissues, such as traumatic brain injury and ischemia, the interpretation of axon diameter alterations in pathology may be significantly confounded.

neuroscience↗

Multi-parametric quantitative spinal cord MRI with unified signal readout and image denoising

Multi-parametric quantitative MRI (qMRI) of the spinal cord is a promising non-invasive tool to probe early microstructural damage in neurological disorders. It is usually performed by combining acquisitions with multiple signal readouts, which exhibit different thermal noise levels, geometrical distortions and susceptibility to physiological noise. This ultimately hinders joint multi-contrast modelling and makes the geometric correspondence of parametric maps challenging. We propose an approach to overcome these limitations, by implementing state-of-the-art microstructural MRI of the spinal cord with a unified signal readout. We base our acquisition on single-shot echo planar imaging with reduced field-of-view, and obtain data from two different vendors (vendor 1: Philips Achieva; vendor 2: Siemens Prisma). Importantly, the unified acquisition allows us to compare signal and noise across contrasts, thus enabling overall quality enhancement via Marchenko-Pastur (MP) Principal Component Analysis (PCA) denoising. MP-PCA is a recent method relying on redundant acquisitions, i.e. such that the number of measurements is much larger than the number of informative principal components. Here we used in vivo and synthetic data to test whether a unified readout enables more efficient denoising of less redundant acquisitions, since these can be denoised jointly with more redundant ones. We demonstrate that a unified readout provides robust multi-parametric maps, including diffusion and kurtosis tensors from diffusion MRI, myelin metrics from two-pool magnetisation transfer, and T1 and T2 from relaxometry. Moreover, we show that MP-PCA improves the quality of our multi-contrast acquisitions, since it reduces the coefficient of variation (i.e. variability) by up to 15% for mean kurtosis, 8% for bound pool fraction (BPF, myelin-sensitive), and 13% for T1, while enabling more efficient denoising of modalities limited in redundancy (e.g. relaxometry). In conclusion, multi-parametric spinal cord qMRI with unified readout is feasible and provides robust microstructural metrics with matched resolution and distortions, whose quality benefits from MP-PCA denoising, a useful pre-processing tool for spinal cord MRI.

neuroscience↗

Spatial relationships between white matter degeneration, amyloid load and cortical volume in amnestic mild cognitive impairment

The spatial-temporal relationships between gray and white matter (WM) degeneration during preclinical and early symptomatic Alzheimers disease are poorly understood. We characterized {beta}-amyloid deposition, cortical volume and WM degeneration in 44 subjects including healthy control (N=23), amnestic mild cognitive impairment (aMCI) (N=19), and early Alzheimers subjects (N=2). Integrated PET-MRI provided simultaneous measurement of 18F-Florbetapir uptake in cortical areas, regional brain volumes from structural MRI, and WM tract integrity metrics from diffusion MRI using biophysical modeling.\n\nAcross the cohort of healthy control and aMCIs, cortical volumes correlated poorly with {beta}-amyloid deposition in the same area (p < 0.05 only in the posterior cingulate and parietal lobe). WM degeneration correlated significantly with both amyloid and volume of connected cortical areas, but more strongly with volume. Diffusion MRI metrics for WM demyelination and/or axonal loss could therefore provide new biomarkers associated with clinical Alzheimers conversion. These WM changes may represent sequential propagation of Alzheimers neurodegeneration between functionally connected regions, and/or evidence of direct WM injury during the Alzheimers pathology cascade.

neuroscience↗

Electron microscopy 3-dimensional segmentation and quantification of axonal dispersion and diameter distribution in mouse brain corpus callosum

To model the diffusion MRI signal in brain white matter, general assumptions have been made about the microstructural properties of axonal fiber bundles, such as the axonal shape and the fiber orientation dispersion. In particular, axons are modeled by perfectly circular cylinders with no diameter variation within each axon, and their directions obey a specific orientation distribution. However, these assumptions have not been validated by histology in 3-dimensional high-resolution neural tissue. Here, we reconstructed sequential scanning electron microscopy images in mouse brain corpus callosum, and introduced a semi-automatic random-walker (RaW) based algorithm to rapidly segment individual intra-axonal spaces and myelin sheaths of myelinated axons. Confirmed with a conventional machine-learning-based interactive segmentation method, our semi-automatic algorithm is reliable and less time-consuming. Based on the segmentation, we calculated histological estimates of size-related (e.g., inner axonal diameter, g-ratio) and orientation-related (e.g., Fiber orientation distribution and its rotational invariants, dispersion angle) quantities, and simulated how these quantities would be observed in actual diffusion MRI experiments by considering diffusion time-dependence. The reported dispersion angle is consistent with previous 2-dimensional histology studies and diffusion MRI measurements, though the reported diameter is larger than those in other mouse brain studies. Our results show that the orientation-related metrics have negligible diffusion time-dependence; however, inner axonal diameters demonstrate a non-trivial time-dependence at diffusion times typical for clinical and preclinical use. In other words, the fiber dispersion estimated by diffusion MRI modeling is relatively independent, while the \"apparent\" axonal size estimated by axonal diameter mapping potentially depends on experimental MRI settings.

neuroscience↗