bioRxiv Science⌕ Search

Biology subjects

Nicholson, T. M.

Publications and source records attributed to Nicholson, T. M..

4 recordsLinked to original sources

Modeling and validation of parallel co-flows layer widths in open-capillary trigger valve systems

Control of fluids is a hallmark of microfluidic systems and fundamental for the successful application of microfluidic devices. Trigger valves use geometric features to autonomously control the release of fluids in microfluidic devices. Our previous work has adapted geometries used in closed trigger valve systems to enable use in open systems, allowing for open microfluidic devices with up to three trigger valves. Here, we focus on the parallel co-flows produced by sequential release of trigger valves and present a model that predicts their layer widths as a function of the geometric characteristics of the different side channels of each trigger valve. We show layered co-flows with widths as low as 50 microns. Additionally, we expand the use of trigger valves in open microfluidic devices by incorporating 1) varied step heights, 2) devices with up to seven trigger valves, and 3) use of varied fluids and plastics. To validate the implementation and use of these trigger valves in open systems, we have developed a theoretical framework to compare predicted outcomes (i.e., fluid travel distance, velocity, and layering width) with our experimental values. This theoretical work offers applications in various fields, including hydrogel patterning for 3D cell culture, organ-on-a-chip models, at-home sample preparation, and autonomous microfluidic systems for biosensing.

bioengineering↗

To the homeRNAmax: Developing an Improved Blood Self-Collection and Stabilization Platform for Remote Transcriptomic Studies

Shifting human subjects research from research sites to participants homes removes barriers to participation, including transportation and scheduling difficulties. Previously, we developed homeRNA, a kit for immediate stabilization of RNA in self-collected blood using a custom-engineered tube containing RNA stabilizer fluid. The stabilized RNA is extracted and used for downstream gene expression analysis. Here, we introduce homeRNAmax, which improves our original design by interfacing with a commercially available blood collection tube (BD Microtainer), allowing homeRNAmax to be used with any blood collection method that uses this tube and doubling the possible sample volume that can be collected and stabilized compared to the original homeRNA. Through a pilot study (n=19 participants), we show that homeRNAmax (with the Tasso+ blood collection device) produces RNA samples of sufficient quality (mean RIN=7.8) and yield (mean yield=1.93 g) for downstream analysis and can reach participants across the United States, who generally (n=17/19) found the homeRNAmax kit easy to use. A key aspect of the homeRNA and homeRNAmax platforms is a fluidic feature that prevents the RNA stabilizer from spilling, however our previous work had not yet fully characterized the mechanism of this feature. Here, we developed a theoretical model of the spill-resistant feature. In brief, fluid in the tube is suspended due to a balance of pressures; an increase in air volume within the tube reduces the air pressure above the fluid, creating a small vacuum, and preventing fluid leakage. Overall, we show that homeRNAmax is a user-friendly, effective tool for remote blood RNA stabilization.

bioengineering↗

The dynamics of capillary flow in an open-channel system featuring trigger valves

Trigger valves are fundamental features in capillary-driven microfluidic systems that stop fluid at an abrupt geometric expansion and release fluid when there is flow in an orthogonal channel connected to the valve. The concept was originally demonstrated in closed-channel capillary circuits. We show here that trigger valves can be successfully implemented in open channels. We also show that a series of open-channel trigger valves can be placed alongside or opposite a main channel resulting in a layered capillary flow. We developed a closed form model for the dynamics of the flow at trigger valves based on the concept of average friction length and successfully validated the model against experiments. For the main channel, we discuss layered flow behavior in the light of the Taylor-Aris dispersion theory and in the channel turns by considering Dean theory of mixing. This work has potential applications in autonomous microfluidics systems for biosensing, at-home or point-of-care sample preparation devices, hydrogel patterning for 3D cell culture and organ-on-a-chip models.

bioengineering↗

Open-Channel Droplet Microfluidic Platform for Passive Generation of Human Sperm Microdroplets

Sperm cryopreservation is important for many individuals across the globe. Recent studies show that vitrification is a valuable approach for maintaining sperm quality after freeze-thawing processes and requires sub-microliter to microliter volumes. A major challenge for the adoption of vitrification in fertility laboratories is the ability to pipette small volumes of sample. Here, we present an open droplet generator that leverages open-channel microfluidics to passively generate sub-microliter to microliter volumes of purified human sperm samples and preserves sperm kinematics. We conclude that our platform is compatible with human sperm, an important foundation for future implementation of vitrification in fertility laboratories. Table of contents artwork O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=108 SRC="FIGDIR/small/593416v3_ufig1.gif" ALT="Figure 1"> View larger version (24K): org.highwire.dtl.DTLVardef@1733ae0org.highwire.dtl.DTLVardef@1e638aorg.highwire.dtl.DTLVardef@119097forg.highwire.dtl.DTLVardef@be86f3_HPS_FORMAT_FIGEXP M_FIG C_FIG

bioengineering↗