Community Challenge towards Consensus on Characterization of Biological Tissue: C4Bios First Findings

This study investigates methodological variability across various expert laboratories worldwide, with regards to characterizing the mechanical properties of biological tissues. Two testing rounds were conducted on the specific use case of uniaxial tensile testing of porcine aorta. In the first round, 24 labs were invited to apply their established methods to assess inter-laboratory variability. This revealed significant methodological diversity and associated variability in the stress-stretch results, underscoring the necessity for a standardized approach. In the second round, a consensus protocol was collaboratively developed and adopted by 19 labs in an attempt to minimize variability. This involved standardized sample preparation and uniformity in testing protocol, including the use of a common cutting and thickness measurement tool. Despite protocol harmonization, significant variability persisted across labs, which could not be solely attributed to inherent biological differences in tissue samples. These results illustrate the challenges in unifying testing methods across different research settings, underlining the necessity for further refinement of testing practices. Enhancing consistency in biomechanical experiments is pivotal when comparing results across studies, as well as when using the resulting material properties for in silico simulations in medical research.

bioengineering↗

Experimental analysis and biaxial biomechanical behaviour of ex-vivo sheep trachea

PurposeThe purpose of this study is to investigate the mechanical behaviour of the tracheal tissue under biaxial tensile loading. Furthermore, the study examines the material properties of the tissue through a study of the model parameters for six constitutive models. Materials and methodsThe fourteen (n = 13) trachea sheep (Vleis Merino) pieces of tissues measured to be ~ 30 x 20 mm where only the effective area subjected to engineering strain was ~ 25 x 16 mm. In this study, we assume that the tracheal tissue is anisotropic and incompressible, therefore we apply and study the material parameters from six models namely the Fung, Choi-Vito, Holzapfel (2000), Holzapfel (2005), Polynomial (Anisotropic) and Four-Fiber Family models. ResultsThe results show that the trachea tissue is twice as stiff along the circumferential direction as it is along the longitudinal direction. It is also observed that the material properties are different (non-homogeneous) along the trachea. ConclusionsThe findings of this study will benefit computational models for the study of tracheal diseases or injuries. Furthermore, these findings will assist in the development of regenerative medicine for different tracheal pathologies and in the bioengineering of replacement tissue in cases of damage.

bioengineering↗

FITTING OF HYPERELASTIC CONSTITUTIVE MODELS IN DIFFERENT SHEEP HEART REGIONS BASED ON BIAXIAL MECHANICAL PROPERTIES

Heart failure remains one of the leading causes of death especially among people over the age of 60 years worldwide. To develop effective therapy and suitable replacement materials for the heart muscle it is necessary to understand its biomechanical behaviour under load. This paper investigates the passive mechanical response of the sheep myocardia excised from three different regions of the heart. Due to the relatively higher cost and huge ethical demands in acquisition and testing of real animal heart models, this paper evaluates the fitting performances of five different constitutive models on the myocardial tissue responses. Ten sheep were sacrificed, and their hearts excised and transported within 3h to the testing biomechanical laboratory. The upper sections of the hearts above the short axes were carefully dissected out. Tissues were dissected from the mid-sections of the left ventricle, mid-wall and right ventricle for each heart. The epicardia and endocardia were then carefully sliced off each tissue to leave the myocardia. Stress-strain curves were calculated, filtered and resampled. The results show that Choi-Vito model was found to provide the best fit to the LV, the polynomial (Anisotropic) model to RV, the Four-Fiber Family model to RV, Holzapfel (2000) to RV, Holzapfel (2005) to RV and the Fung model to LV.