bioRxiv Science⌕ Search

Biology subjects

Murray, W. M.

Publications and source records attributed to Murray, W. M..

7 recordsLinked to original sources

High-density surface EMG grid enables non-invasive characterization of intrinsic hand muscles activity

Understanding the neuromuscular properties that allow dexterous manipulation of objects remains a major challenge in neurorehabilitation, largely due to the difficulty of characterizing intrinsic hand muscle activity. These muscles are small, densely packed, and anatomically complex, making selective recordings with intramuscular electromyography (EMG) technically demanding and impractical for comprehensive studies. In this work, we present a custom, high-density (HD) surface EMG grid designed to non-invasively capture activity from intrinsic hand muscles from both dorsal and palmar surfaces. We evaluated the quality and spatial selectivity of the recordings by directly comparing them with intramuscular EMG signals obtained from the dorsal and palmar interossei. Surface EMG signals corresponded closely to the intramuscular recordings, with high correlation values for all subjects and tasks. Double differential spatial filtering significantly improved selectivity, although some residual volume conduction remained. The dorsal grid primarily captured dorsal interossei activity, while the palmar grid was more sensitive to lumbrical activation. The palmar interossei recordings were spatially more varied, with the second palmar interosseous predominantly detected on the dorsal grid and the third and fourth on the palmar grid. Together, these results demonstrate that non-invasive HD surface EMG will allow more complete measurement of intrinsic muscle activity, to provide a better understanding of the complex relation between the intrinsic and extrinsic hand muscles during dexterous movements. This basic information will allow refinement of biomechanical hand models and prosthetic devices, and the development of biomimetic brain computer interfaces aimed at restoring natural hand function after neurological injury.

bioengineering↗

Muscle-driven hand simulations emphasize the critical role of the extensor mechanism

Biomechanical simulations of complex hand motions remain scarce, due to challenges that span computation and data acquisition. Using a computer vision-based motion capture approach, a 23-degree of freedom musculoskeletal model, and direct collocation optimization, we performed muscle-driven simulations to track hand kinematics from 7 participants performing American Sign Language gestures. While proximal joints were tracked accurately, interphalangeal joint tracking was significantly worse, with a consistent flexion bias. Modifications to finger extensor muscle paths that incorporated the dual-inserting nature of the extensors improved accuracy, suggesting better representation of extensor force distribution across distal joints may be necessary for accurate hand simulations.

bioengineering↗

Soft, 3D printed muscle ultrasound phantom with structurally tunable B-mode echo intensity

OBJECTIVESImaging phantoms for training and validation are vital to improving the performance and adoption of ultrasound imaging modalities in clinical and pre-clinical applications, and the goal of this study was to assess the viability of 3D printed muscle ultrasound phantoms to meet this need. METHODSWe used a soft stereolithography resin to 3D print phantoms that mimicked the fascicle- and perimysium-scale structure of skeletal muscle and compared the long axis B-mode imaging quality and pattern of the phantom to that of healthy, adult Biceps brachii. We used a pulse-echo, time-of-flight method to measure the acoustic impedance of the resin for comparison to skeletal muscle and common soft tissue mimicking materials. We analyzed the echo intensity (EI) of muscle images to establish a physiological range and compared the EI of different phantom designs to assess the ability to control imaging brightness through structural modification. RESULTSA linear, striated hyper-/hypo-echoic B-mode imaging pattern mimicking long axis Biceps brachii muscle images was achieved with two 3D structure paradigms, rod and honeycomb. Acoustic impedance of Elastic 50A resin is higher than skeletal muscle in bulk, but appears suitable for use in a 3D structured phantom. EI measured in the Biceps images were found to vary both within and across images with an overall mean {+/-} SD of 87 {+/-}13 AU. EI measured in honeycomb phantoms (55 {+/-}15 AU) was higher than in rod phantoms (42 {+/-}13 AU), and a latticed honeycomb further increased EI (90 {+/-}11 AU). CONCLUSIONSThis study serves as proof-of-concept for soft, 3D printed phantoms that replicate the characteristic muscle ultrasound imaging pattern with the ability to tune clinically relevant EI values via structural design.

bioengineering↗

A Musculoskeletal Model of the Hand and Wrist Capable of Simulating Functional Tasks

ObjectiveThe purpose of this work was to develop an open-source musculoskeletal model of the hand and wrist and to evaluate its performance during simulations of functional tasks. MethodsThe musculoskeletal model was developed by adapting and expanding upon existing musculoskeletal models. An optimal control theory framework that combines forward-dynamics simulations with a simulated-annealing optimization was used to simulate maximum grip and pinch force. Active and passive hand opening were simulated to evaluate coordinated kinematic hand movements. ResultsThe models maximum grip force production matched experimental measures of grip force, force distribution amongst the digits, and displayed sensitivity to wrist flexion. Simulated lateral pinch strength fell within variability of in vivo palmar pinch strength data. Additionally, predicted activation for 7 of 8 muscles fell within variability of EMG data during palmar pinch. The active and passive hand opening simulations predicted reasonable activations and demonstrated passive motion mimicking tenodesis, respectively. ConclusionThis work advances simulation capabilities of hand and wrist models and provides a foundation for future work to build upon. SignificanceThis is the first open-source musculoskeletal model of the hand and wrist to be implemented during both functional kinetic and kinematic tasks. We provide a novel simulation framework to predict maximal grip and pinch force which can be used to evaluate how potential surgical and rehabilitation interventions influence these functional outcomes while requiring minimal experimental data.

bioengineering↗

Variability of in vivo sarcomere length measures in the upper limb obtained with second harmonic generation microendoscopy

The lengths of a muscles sarcomeres are a primary determinant of its ability to contract and produce force. In addition, sarcomere length is a critical parameter that is required to make meaningful comparisons of both the force-generating and excursion capacities of different muscles. Until recently, in vivo sarcomere length data have been limited to invasive or intraoperative measurement techniques. With the advent of second harmonic generation microendosopy, minimally invasive measures of sarcomere length can be made for the first time. This imaging technique expands our ability to study muscle adaptation due to changes in stimulus, use, or disease. However, due to the inability to measure sarcomeres outside of surgery or biopsy, little is known about the natural, anatomical variability in sarcomere length in living human subjects. To develop robust experimental protocols that ensure data provide accurate representations of a muscles sarcomere lengths, we sought to quantify experimental uncertainty associated with in vivo measures of sarcomere lengths. Specifically, we assessed the variability in sarcomere length measured 1) within a single image, along a muscle fiber, 2) across images captured within a single trial, across trials, and across days, as well as 3) across locations in the muscle using second harmonic generation in two upper limb muscles with different muscle architectures, functions, and sizes. Across all of our measures of variability we estimate that the magnitude of the uncertainty in in vivo sarcomere length are on the order of ~0.25m. In the two upper limb muscles studied we found larger variability in sarcomere length within a single insertion than across locations. We also developed custom code to make measures of sarcomere length variability across a single fiber and determined that this codes accuracy is an order of magnitude smaller than our measurement uncertainty due to sarcomere variability. Together, our findings provide guidance for the development of robust experimental design and analysis of in vivo sarcomere lengths in the upper limb.

bioengineering↗

Serial sarcomere number is substantially decreased within the paretic biceps brachii in chronic hemiparetic stroke

A muscles structure, or architecture, is indicative of its function and is plastic; changes in input to or use of the muscle alter its architecture. Stroke-induced neural deficits substantially alter both input to and usage of individual muscles. Here, we combined novel in vivo imaging methods (second harmonic generation microendoscopy, extended field-of-view ultrasound, and fat-supression MRI) to quantify functionally meaningful muscle architecture parameters in the biceps brachii of both limbs of individuals with chronic hemiparetic stroke and in age-matched, unimpaired controls. Specifically, serial sarcomere number and physiological cross-sectional area were calculated from data collected at three anatomical scales: sarcomere length, fascicle length, and muscle volume. Our data indicate that the paretic biceps brachii had ~8,500 fewer serial sarcomeres compared to the contralateral limb (p=0.0044). In the single joint posture tested, the decreased serial sarcomere number was manifested by significantly shorter fascicles (10.7cm vs 13.6cm; p<0.0001) without significant differences in sarcomere lengths (3.58m vs. 3.54m; p=0.6787) in the paretic compared to the contralateral biceps. No interlimb differences were observed in unimpaired controls, suggesting we observed muscle adaptations associated with stroke rather than natural interlimb variability. This study provides the first direct evidence of the loss of serial sarcomeres in human muscle, observed in a population with neural impairments that lead to disuse and chronically place the affected muscle at a shortened position. This adaptation is consistent with functional consequences (increased passive resistance to elbow extension) that would amplify already problematic, neurally driven motor impairments. SIGNIFICANCE STATEMENTSerial sarcomere number determines a muscles length during maximum force production and its available length range for active force generation. Skeletal muscle length adapts to functional demands; for example, animal studies demonstrate that chronically shortened muscles decrease length by losing serial sarcomeres. This phenomenon has never been demonstrated in humans. Integrating multi-scale imaging techniques, including two photon microendoscopy, an innovative advance from traditional, invasive measurement methods at the sarcomere scale, we establish that chronic impairments that place a muscle in a shortened position are associated with the loss of serial sarcomeres in humans. Understanding how muscle adapts following impairment is critical to the design of more effective clinical interventions to mitigate such adaptations and to improve function following motor impairments.

bioengineering↗

Model-based control of individual finger movements for prosthetic hand function

Prosthetic devices for hand difference have advanced considerably in recent years, to the point where the mechanical dexterity of a state-of-the-art prosthetic hand approaches that of the natural hand. Control options for users, however, have not kept pace, meaning that the new devices are not used to their full potential. Promising developments in control technology reported in the literature have met with limited commercial and clinical success. We have previously described a biomechanical model of the hand that could be used for prosthesis control. In this study, we report on three key elements of the biomechanical simulations relevant to prosthesis control: we show the performance of the model in replicating recorded hand kinematics and find average correlations of 0.89 between modelled and recorded motions; we show that the computational performance of the simulations is fast enough to achieve real-time control with a robotic hand in the loop; and we describe the use of the model for controlling object gripping. Despite some limitations in accessing sufficient driving signals, the model performance shows promise as a controller for prosthetic hands when driven with recorded EMG signals. We identify areas for future work to address these limitations.

bioengineering↗