bioRxiv Science⌕ Search

Biology subjects

Mukkunda, S. R.

Publications and source records attributed to Mukkunda, S. R..

2 recordsLinked to original sources

Functional Assessment of Cardiac Beat Dynamics Under Dynamic Flow: Insights from the Mera Microphysiological System

Cardiac rhythm is a critical clinical indicator for cardiac arrhythmias and adverse events during drug toxicity studies. In vivo, cardiomyocyte responses to pharmacological agents occur within minutes and are strongly influenced by dynamic drug delivery through blood flow. However, conventional 2D and 3D static culture systems fail to replicate these fluid flow kinetics, limiting their physiological relevance for assessing beat rate responses. Here, we present Mera, an advanced microphysiological system (MPS) developed by Hooke Bio, designed for high-throughput, long-term culture and functional analysis of 3D cardiac spheroids composed of human induced pluripotent stem cell-derived cardiomyocytes and cardiac fibroblasts. Mera enables dynamic perfusion, allowing investigation of cardiomyocyte beat rates under physiologically relevant flow conditions. The platform supports up to 640 spheroids per run and integrates automated imaging, fluid handling, and user-friendly software, operating under controlled physiological conditions (37{degrees}C, 5% CO2). Flow rates are tunable between 0 and 12.5 mL/min to mimic in vivo environments. Pharmacological testing with verapamil, isoproterenol, calcium chloride, and propranolol demonstrated real-time, reversible modulation of beat rate under flow, including recovery following drug-induced suppression. System variability was comparable to a temperature-controlled reference platform, supporting robust statistical analysis. Dose-response studies yielded IC values consistent with literature, confirming physiological relevance. Collectively, these results demonstrate that Mera provides a reproducible, scalable, and human-relevant platform for cardiac drug testing. By enabling dynamic drug exposure and automated analysis, Mera represents a powerful new approach methodology (NAM) for improving the predictive assessment of cardiac safety and beat-rate modulation drug responses.

bioengineering↗

Mera: A scalable high throughput automated micro-physiological system

There is an urgent need for scalable Microphysiological Systems (MPSs)1 that can better predict drug efficacy and toxicity at the preclinical screening stage. Here we present Mera, an automated, modular and scalable system for culturing and assaying microtissues with interconnected fluidics, inbuilt environmental control and automated image capture. The system presented has multiple possible fluidics modes. Of these the primary mode is designed so that cells may be matured into a desired microtissue type and in the secondary mode the fluid flow can be re-orientated to create a recirculating circuit composed of inter-connected channels to allow drugging or staining. We present data demonstrating the prototype system Mera using an Acetaminophen/HepG2 liver microtissue toxicity assay with Calcein AM and Ethidium Homodimer (EtHD1) viability assays. We demonstrate the functionality of the automated image capture system. The prototype microtissue culture plate wells are laid out in a 3 x 3 or 4 x 10 grid format with viability and toxicity assays demonstrated in both formats. In this paper we set the groundwork for the Mera system as a viable option for scalable microtissue culture and assay development.

bioengineering↗