bioRxiv Science⌕ Search

Biology subjects

Mueller-Schrader, M.

Publications and source records attributed to Mueller-Schrader, M..

2 recordsLinked to original sources

Bayesian Workflow for Generative Modeling in Computational Psychiatry

Computational (generative) modelling of behaviour has considerable potential for clinical applications. In order to unlock the potential of generative models, reliable statistical inference is crucial. For this, Bayesian workflow has been suggested which, however, has rarely been applied in Translational Neuromodeling and Computational Psychiatry (TN/CP) so far. Here, we present a worked example of Bayesian workflow in the context of a typical application scenario for TN/CP. This application example uses Hierarchical Gaussian Filter (HGF) models, a family of computational models for hierarchical Bayesian belief updating. When equipped with a suitable response model, HGF models can be fit to behavioural data from cognitive tasks; these data frequently consist of binary responses and are typically univariate. This poses challenges for statistical inference due to the limited information contained in such data. We present a novel set of response models that allow for simultaneous inference from multivariate (here: two) behavioural data types. Using both simulations and empirical data from a speed-incentivised associative reward learning (SPIRL) task, we show that harnessing information from two different data streams (binary responses and continuous response times) improves the accuracy of inference (specifically, identifiability of parameters and models). Moreover, we find a linear relationship between log-transformed response times in the SPIRL task and participants uncertainty about the outcome. Our analysis illustrates the benefits of Bayesian workflow for a typical use case in TN/CP. We argue that adopting Bayesian workflow for generative modelling helps increase the transparency and robustness of results, which in turn is of fundamental importance for the long-term success of TN/CP.

neuroscience↗

Advances in Spiral fMRI: A High-resolution Study with Single-shot Acquisition

Spiral fMRI has been put forward as a viable alternative to rectilinear echo-planar imaging, in particular due to its enhanced average k-space speed and thus high acquisition efficiency. This renders spirals attractive for contemporary fMRI applications that require high spatiotemporal resolution, such as laminar or columnar fMRI. However, in practice, spiral fMRI is typically hampered by its reduced robustness and ensuing blurring artifacts, which arise from imperfections in both static and dynamic magnetic fields. Recently, these limitations have been overcome by the concerted application of an expanded signal model that accounts for such field imperfections, and its inversion by iterative image reconstruction. In the challenging ultra-high field environment of 7 Tesla, where field inhomogeneity effects are aggravated, both multi-shot and single-shot 2D spiral imaging at sub-millimeter resolution was demonstrated with high depiction quality and anatomical congruency. In this work, we further these advances towards a time series application of spiral readouts, namely, single-shot spiral BOLD fMRI at 0.8 mm in-plane resolution. We demonstrate that high-resolution spiral fMRI at 7 T is not only feasible, but delivers both excellent image quality, BOLD sensitivity, and spatial specificity of the activation maps, with little artifactual blurring. Furthermore, we show the versatility of the approach with a combined in/out spiral readout at a more typical resolution (1.5 mm), where the high acquisition efficiency allows to acquire two images per shot for improved sensitivity by echo combination. HighlightsO_LIThis work reports the first fMRI study at 7T with high-resolution spiral readout gradient waveforms. C_LIO_LIWe achieve spiral fMRI with sub-millimeter resolution (0.8 mm, FOV 230 mm), acquired in a single shot (36 slices in 3.3 s). C_LIO_LISpiral images exhibit intrinsic geometric congruency to anatomical scans, and spatially specific activation patterns. C_LIO_LIImage reconstruction rests on a signal model expanded by measured trajectories and static field maps, inverted by cg-SENSE. C_LIO_LIWe assess generalizability of the approach for spiral in/out readouts, providing two images per shot (1.5 mm resolution). C_LI

neuroscience↗