bioRxiv Science⌕ Search

Biology subjects

Moroni, M.

Publications and source records attributed to Moroni, M..

5 recordsLinked to original sources

Coherent Cross-modal Generation of Synthetic Biomedical Data to Advance Multimodal Precision Medicine

Integration of multimodal, multi-omics data is critical for advancing precision medicine, yet its application is frequently limited by incomplete datasets where one or more modalities are missing. To address this challenge, we developed a generative framework capable of synthesizing any missing modality from an arbitrary subset of available modalities. We introduce Coherent Denoising, a novel ensemble-based generative diffusion method that aggregates predictions from multiple specialized, single-condition models and enforces consensus during the sampling process. We compare this approach against a multi-condition, generative model that uses a flexible masking strategy to handle arbitrary subsets of inputs. The results show that our architectures successfully generate high-fidelity data that preserve the complex biological signals required for downstream tasks. We demonstrate that the generated synthetic data can be used to maintain the performance of predictive models on incomplete patient profiles and can leverage counterfactual analysis to guide the prioritization of diagnostic tests. We validated the frameworks efficacy on a large-scale multimodal, multi-omics cohort from The Cancer Genome Atlas (TCGA) of over 10,000 samples spanning across 20 tumor types, using data modalities such as copy-number alterations (CNA), transcriptomics (RNA-Seq), proteomics (RPPA), and histopathology (WSI). This work establishes a robust and flexible generative framework to address sparsity in multimodal datasets, providing a key step toward improving precision oncology. Author SummaryTo make precision medicine a reality, doctors need to understand a patients status from many angles, using different data types like genetic information (omics) and tissue slide images (histopathology). The problem is that most patient records are incomplete, with one or more of these data types missing, which can limit the effectiveness of powerful predictive tools. We have built a generative AI system designed to learn the complex biological patterns that connect all these different data types. By looking at the patient data that is available, our system can then generate a realistic, synthetic version of any missing piece. We developed a novel method called Coherent Denoising to do this, which is flexible and helps protect patient privacy. We validated this approach on a large dataset of over 10,000 cancer patient profiles. We show that our AI-generated data is high-fidelity and can successfully complete these sparse patient profiles, allowing AI models for crucial tasks like cancer staging and survival prediction to work at their best even with incomplete patient data. We also demonstrate how this tool can be used to evaluate the potential impact of new tests, helping to prioritize which expensive diagnostic tests would be most beneficial for a patient.

bioinformatics↗

Aberration correction in long GRIN lens-based microendoscopes for extended field-of-view two-photon imaging in deep brain regions

Two-photon (2P) fluorescence imaging through gradient index (GRIN) lens-based endoscopes is fundamental to investigate the functional properties of neural populations in deep brain circuits. However, GRIN lenses have intrinsic optical aberrations, which severely degrade their imaging performance. GRIN aberrations decrease the signal-to-noise ratio (SNR) and spatial resolution of fluorescence signals, especially in lateral portions of the field-of-view (FOV), leading to restricted FOV and smaller number of recorded neurons. This is especially relevant for GRIN lenses of several millimeters in length, which are needed to reach the deeper regions of the rodent brain. We have previously demonstrated a novel method to enlarge the FOV and improve the spatial resolution of 2P microendoscopes based on GRIN lenses of length < 4.1 mm (Antonini et al. eLife 2020). However, previously developed microendoscopes were too short to reach the most ventral regions of the mouse brain. In this study, we combined optical simulations with fabrication of aspherical polymer microlenses through three-dimensional (3D) microprinting to correct for optical aberrations in long (length > 6 mm) GRIN lens-based microendoscopes (diameter, 500 {micro}m). Long corrected microendoscopes had improved spatial resolution, enabling imaging in significantly enlarged FOVs. Moreover, using synthetic calcium data we showed that aberration correction enabled detection of cells with higher SNR of fluorescent signals and decreased cross-contamination between neurons. Finally, we applied long corrected microendoscopes to perform large-scale and high precision recordings of calcium signals in populations of neurons in the olfactory cortex, a brain region laying approximately 5 mm from the brain surface, of awake head-tethered mice. Long corrected microendoscopes are powerful new tools enabling population imaging with unprecedented large FOV and high spatial resolution in the most ventral regions of the mouse brain.

neuroscience↗

Extended field-of-view ultrathin microendoscopes for high-resolution two-photon imaging with minimal invasiveness in awake mice

Imaging neuronal activity with high and homogeneous spatial resolution across the field-of-view (FOV) and limited invasiveness in deep brain regions is fundamental for the progress of neuroscience, yet is a major technical challenge. We achieved this goal by correcting optical aberrations in gradient index lens-based ultrathin ([&le;] 500 {micro}m) microendoscopes using aspheric microlenses generated through 3D-microprinting. Corrected microendoscopes had extended FOV (eFOV) with homogeneous spatial resolution for two-photon fluorescence imaging and required no modification of the optical set-up. Synthetic calcium imaging data showed that, compared to uncorrected endoscopes, eFOV-microendoscopes led to improved signal-to-noise ratio and more precise evaluation of correlated neuronal activity. We experimentally validated these predictions in awake head-fixed mice. Moreover, using eFOV-microendoscopes we demonstrated cell-specific encoding of behavioral state-dependent information in distributed functional subnetworks in a primary somatosensory thalamic nucleus. eFOV-microendoscopes are, therefore, small-cross-section ready-to-use tools for deep two-photon functional imaging with unprecedentedly high and homogeneous spatial resolution.

neuroscience↗

Manipulating synthetic optogenetic odors reveals the coding logic of olfactory perception

How does neural activity generate perception? The spatial identities and temporal latencies of activated units correlate with external sensory features, but finding the principal activity subspace that is consequential for perception, remains challenging. We trained mice to recognize synthetic odors constructed from parametrically-defined patterns of optogenetic activation, then measured perceptual changes during extensive and controlled perturbations across spatio-temporal dimensions. We modelled recognition as the matching of patterns to learned templates, finding that perceptually-meaningful templates are sequences of spatially-identified units, ordered by latencies relative to each other (with minimal effects of sniff). Within templates, individual units contribute additively, with larger contributions from earlier-activated units. Our synthetic approach reveals the fundamental logic of the olfactory code, and provides a general framework for testing links between sensory activity and perception.

neuroscience↗

Voltage-gating of mechanosensitive PIEZO channels

Mechanosensitive PIEZO ion channels are evolutionarily conserved proteins whose presence is critical for normal physiology in multicellular organisms. Here we show that, in addition to mechanical stimuli, PIEZO channels are also powerfully modulated by voltage and can even switch to a purely voltage gated mode. Mutations that cause human diseases such as Xerocytosis profoundly shift voltage sensitivity of PIEZO1 channels towards the resting membrane potential and strongly promote pure voltage gating. Our data may be explained by the presence of an inactivation gate in the pore, the opening of which is promoted by outward permeation. Invertebrate (fly) and vertebrate (fish) PIEZO proteins are also voltage sensitive but voltage gating is a much more prominent feature of these older channels. We propose that the voltage sensitivity of PIEZO channels is a deep property co-opted to add a regulatory mechanism for PIEZO activation in widely different cellular contexts.

neuroscience↗