bioRxiv Science⌕ Search

Biology subjects

Mermer, A.

Publications and source records attributed to Mermer, A..

3 recordsLinked to original sources

Small-Molecule Structure Determination and Anisotropic Displacement Analysis at Turkish Light Source

Single-crystal X-ray diffraction remains one of the most direct and reliable techniques for clarifying the three-dimensional structures of small molecules; however, its wider use in developing research settings has historically been limited by access to advanced instrumentation. Here, we consider the performance of the in-house diffractometer, Turkish Light Source, for small-molecule structure determination using three rhodanine-derivative compounds. Diffraction data were collected, processed, and followed by full-matrix least-squares refinement as a user-friendly pipeline. The compounds were successfully resolved in the triclinic space group P-1 and refined to chemically reasonable models, although notable differences in data quality and refinement parameters were observed. Compounds 1 and 2 produced the most robust and internally coherent structure, whereas compound 3 displayed refinement tribulations. These might be attributed to the intrinsic structural disorder of c-5b, analogous to polymorphic perversity in higher Z' phase, likely due to the presence of dissymmetric molecules within the asymmetric unit (Z' = 2), rather than empirical limitations. Anisotropic displacement parameters were systematically computed by atom-resolved Ueq factors and anisotropy index. The combined analyses reveal that structural ambiguity of c-5b is largely governed by localized maxima in atomic displacement (up to 0.29 [A]2 in Ueq with 6.67 anisotropy) rather than by global disorder, caused by the fluorinated aryl moiety of c-5b. These findings indicate that the in-house SCXRD system, when coupled with our user-friendly downstream pipeline, can yield reliable structural data for small molecules. Brief video tutorials and detailed SOPs have been provided in the Tutorials folder, including CrysAlisPro and Olex2 tutorials, as well as are easily accessible for users.

biophysics↗

A novel sample delivery method for powder X-ray diffraction at Turkish Light Source

Powder X-ray diffraction (PXRD) measurements performed on platforms originally designed for single-crystal diffraction are strongly affected by how the powder sample is presented to the X-ray beam, including the delivery configuration and support geometry. Here, we developed a modified Terasaki-plate-based sample-delivery method for PXRD using a laboratory single-crystal diffractometer implemented with the XtalCheck-S plate-reader operational mode at Turkish Light Source. The method was regarded under comparable measurement conditions relative to a standard loop/pin-based and a grease-based Terasaki setup using 5-{[4-(2-Methoxyphenyl)piperazin-1-yl]methyl}-4-ethyl-4H-1,2,4-triazole-3-thiol as a model analyte. The loop-based method allowed only limited powder sampling, whereas the grease-based Terasaki setup enabled multi-well sample delivery but produced higher background and weaker diffraction profiles. Conversely, Kapton-sealed Terasaki ensured secure retention of small amounts powder while providing lower background and clearer diffraction patterns. Within short total data collection times of only 1-2 min, the Kapton-Terasaki method delivered the best overall PXRD performance among the tested methods. Search-match and profile-fitting analyses showed that all three approaches sampled the same crystalline material, while the Kapton-based method gave the lowest profile residual (Rp = 9.6%) and the most reliable whole-pattern profile. These results demonstrate that optimizing sample delivery, rather than modifying the core instrument hardware, can substantially extend PXRD capability on an existing in situ crystallography platform for rapid, laboratory-based screening and comparative multi-sample measurements.

biochemistry↗

Cryogenic X-ray crystallographic studies of biomacromolecules at Turkish Light Source: Turkish DeLight

X-ray crystallography is a robust and powerful structural biology technique that provides high-resolution atomic structures of biomacromolecules. Scientists use this technique to unravel mechanistic and structural details of biological macromolecules (e.g. proteins, nucleic acids, protein complexes, protein-nucleic acid complexes, or large biological compartments). Since its inception, single-crystal cryo-crystallography has never been performed in Turkiye due to the lack of a single-crystal X-ray diffractometer. The X-ray diffraction facility recently established at the University of Health Sciences, Istanbul, Turkiye will enable Turkish and international researchers to easily perform high-resolution structural analysis of biomacromolecules from single crystals. Here, we describe the technical and practical outlook of a state-of-the-art home-source X-ray, using lysozyme as a model protein. The methods and practice described in this article can be applied to any biological sample for structural studies. Therefore, this article will be a valuable practical guide from sample preparation to data analysis.

biophysics↗