bioRxiv Science⌕ Search

Biology subjects

Mendez Rojano, R.

Publications and source records attributed to Mendez Rojano, R..

2 recordsLinked to original sources

A fibrin enhanced thrombosis model for medical devices operating at low shear regimes or large surface areas

Over the past decade, much of the development of computational models of device-related thrombosis has focused on platelet activity. While those models have been successful in predicting thrombus formation in medical devices operating at high shear rates (> 5000 s-1), they cannot be directly applied to low-shear devices, such as blood oxygenators and catheters, where emerging information suggest that fibrin formation is the predominant mechanism of clotting and platelet activity plays a secondary role. In the current work, we augment an existing platelet-based model of thrombosis with a partial model of the coagulation cascade that includes contact activation of factor XII and fibrin production. To calibrate the model, we simulate a backward-facing-step flow channel that has been extensively characterized in-vitro. Next, we perform blood perfusion experiments through a microfluidic chamber mimicking a hollow fiber membrane oxygenator and validate the model against these observations. The simulation results closely match the time evolution of the thrombus height and length in the backward-facing-step experiment. Application of the model to the microfluidic hollow fiber bundle chamber capture both gross features such as the increasing clotting trend towards the outlet of the chamber, as well as finer local features such as the structure of fibrin around individual hollow fibers. Our results are in line with recent findings that suggest fibrin production, through contact activation of factor XII, drives the thrombus formation in medical devices operating at low shear rates with large surface area to volume ratios. Author summaryPatients treated with blood-contacting medical devices suffer from clotting complications. Over the past decades, a great effort has been made to develop computational tools to predict and prevent clot formation in these devices. However, most models have focused on platelet activity and neglected other important parts of the problem such as the coagulation cascade reactions that lead to fibrin formation. In the current work, we incorporate this missing element into a well-established and validated model for platelet activity. We then use this novel approach to predict thrombus formation in two experimental configurations. Our results confirm that to accurately predict the clotting process in devices where surface area to volume ratios are large and flow velocity and shear stresses remain low, coagulation reactions and subsequent fibrin formation must be considered. This new model could have great implications for the design and optimization of medical devices such as blood oxygenators. In the long term, the model could evolve into a functional tool to inform anticoagulation therapies for these patients.

bioengineering↗

Critical evaluation of kinetic schemes for coagulation

Computational models of the coagulation cascade are used for a wide range of applications in bio-medical engineering such as drug and bio-medical device developments. However, a lack of robustness of numerical models has been highlighted when studying clinically relevant scenarios. In order to develop more robust models, numerical simulations need to be confronted with realistic situations relevant to clinical practice. In this work, two well-established numerical representations of the coagulation cascade initiated by the intrinsic and extrinsic systems, respectively, were compared with thrombin generation assays considering realistic pathological conditions. Proper modifications were needed to align the in vitro and in silico data, namely; adapting initial conditions to the thrombin assay system, omitting reactions irrelevant to our case study, and improving the fitting of some reaction rates. The modified models were able to capture the experimental trends of thrombin generation for a range of concentrations of factors XII, XI, and VIII for cases in which the coagulation cascade is triggered through the extrinsic and intrinsic systems. Our work emphasizes that when existing coagulation cascade models are extrapolated to experimental settings for which they were not calibrated, careful adjustments must be made. We show that the two coagulation models used in this work can predict physiological conditions, but when studying pathological conditions, proper modifications are needed to improve the numerical results.

systems biology↗