bioRxiv Science⌕ Search

Biology subjects

Lundy, J.

Publications and source records attributed to Lundy, J..

3 recordsLinked to original sources

No evidence for enhanced disease with polyclonal SARS-CoV-2 antibody in the ferret model.

Since SARS-CoV-2 emerged in late 2019, it spread from China to the rest of the world. An initial concern was the potential for vaccine- or antibody-enhanced disease (AED) as had been reported with other coronaviruses. To evaluate this, we first developed a ferret model by exposing ferrets to SARS-CoV-2 by either mucosal inoculation (intranasal/oral) or inhalation using a small particle aerosol. Mucosal inoculation caused a mild fever and weight loss that resolved quickly; inoculation via either route resulted in virus shedding detected in the nares, throat, and rectum for 7-10 days post-infection. To evaluate the potential for AED, we then inoculated groups of ferrets intravenously with 0.1, 0.5, or 1 mg/kg doses of a human polyclonal anti-SARS-CoV-2 IgG from hyper-immunized transchromosomic bovines (SAB-185). Twelve hours later, ferrets were challenged by mucosal inoculation with SARS-CoV-2. We found no significant differences in fever, weight loss, or viral shedding after infection between the three antibody groups or the controls. Signs of pathology in the lungs were noted in infected ferrets but no differences were found between control and antibody groups. The results of this study indicate that healthy, young adult ferrets of both sexes are a suitable model of mild COVID-19 and that low doses of specific IgG in SAB-185 are unlikely to enhance the disease caused by SARS-CoV-2.

microbiology↗

Long-term persistence of viral RNA and inflammation in the CNS of macaques exposed to aerosolized Venezuelan equine encephalitis virus.

Venezuelan equine encephalitis virus (VEEV) is a positively-stranded RNA arbovirus of the genus Alphavirus that causes encephalitis in humans. Cynomolgus macaques are a relevant model of the human disease caused by VEEV and are useful in exploring pathogenic mechanisms and the host response to VEEV infection. Macaques were exposed to small-particle aerosols containing virus derived from an infectious clone of VEEV strain INH-9813, a subtype IC strain isolated from a human infection. VEEV-exposed macaques developed a biphasic fever after infection similar to that seen in humans. Maximum temperature deviation correlated with the inhaled dose, but fever duration did not. Neurological signs, suggestive of virus penetration into the CNS, were predominantly seen in the second febrile period. Electroencephalography data indicated a statistically significant decrease in all power bands and circadian index during the second febrile period that returned to normal after fever resolved. Intracranial pressure increased late in the second febrile period. On day 6 post-infection macaques had high levels of MCP-1 and IP-10 chemokines in the CNS, as well as a marked increase of T lymphocytes and activated microglia. More than four weeks after infection, viral genomic RNA was found in the brain, cerebrospinal fluid and cervical lymph nodes. Pro-inflammatory cytokines & chemokines, infiltrating leukocytes and pathological changes were seen in the CNS tissues of macaques euthanized at these times. These data are consistent with persistence of virus replication and/or genomic RNA and potentially, inflammatory sequelae in the central nervous system after resolution of acute VEEV disease.

immunology↗

High accuracy DNA sequencing on a small, scalable platform via electrical detection of single base incorporations

High throughput DNA sequencing technologies have undergone tremendous development over the past decade. Although optical detection-based sequencing has constituted the majority of data output, it requires a large capital investment and aggregation of samples to achieve optimal cost per sample. We have developed a novel electronic detection-based platform capable of accurately detecting single base incorporations. The GenapSys technology with its electronic detection modality allows the system to be compact, accessible, and affordable. We demonstrate the performance of the system by sequencing several different microbial genomes with varying GC content. The platform is capable of generating up to 2 Gb of high-quality nucleic acid sequence in a single run. We routinely generate sequence data that exceeds 99% raw accuracy with read lengths of up to 175 bp. Average quality scores remain above Q30 (99.9% raw sequencing accuracy) beyond 150 bp, with more than 85% of total bases at or above Q30. The utility of the platform is highlighted by targeted sequencing of the human genome. We show high concordance of SNP detection on the human NA12878 HapMap cell line with data generated on the Illumina sequencing platform. In addition, we sequenced a targeted panel of cancer-associated genes in a well characterized reference standard. With multiple library preparation approaches on this sample, we were able to identify low frequency mutations at expected allele frequencies.

genomics↗