Low Intensity Multi-Channel Steering TMS Array for Network Level Neuromodulation

Objective: Low-intensity transcranial magnetic stimulation (LI-TMS) is being investigated as a gel-free alternative to transcranial electrical stimulation (tES), but existing systems remain almost exclusively single-channel and cannot electronically steer the induced electric field. We present the design, modeling, and experimental measurement of a wearable whole-head, multichannel, steerable LI-TMS array. Methods: The system comprises a 102-channel conformal coil array with independently controlled drivers capable of arbitrary waveform synthesis, together with a boundary element fast multipole method (BEM-FMM) framework that computes the coil currents required to produce prescribed cortical field patterns. A 12-channel prototype was characterized by coil-current, electric-field, and thermal measurements. Results: The prototype produced a peak primary electric field of approximately 1 V/m measured in air 4 cm from the inner helmet surface. Whole-array modeling attained cortical fields of up to 1.5 V/m, reproduced the field distribution of a clinically validated low-intensity stimulator to within 3%-5%, and demonstrated focal targeting of the dorsolateral prefrontal cortex, simultaneous delivery of electric field to the default mode network nodes, and synthesis of electric fields following the traveling alpha wave. Conclusion: Electronically steerable, whole-head LI-TMS is feasible using accessible microprocessor-controlled power electronics. Significance: The array reaches the cortical field regime of tES without scalp contact or the associated shunting of current through the scalp, offering a route to testing network-level, phaselocked weak-field neuromodulation.

bioengineering↗

Direct Reconstruction of DC Cortical Conductivity from Large-Scale Electron Microscopy Data

Electrical conductivity of cortical gray matter governs the magnitude and spatial distribution of electric fields generated by brain stimulation and intrinsic neuronal activity measured with M/EEG and intracortical recordings. However, reported macroscopic conductivity values vary by more than threefold, limiting the fidelity of bioelectromagnetic models and leaving unresolved whether this variability reflects measurement uncertainty or genuine structural heterogeneity of cortical tissue. Here, we present a multiscale computational framework that, for the first time, attempts to derive mesoscale conductivity maps of mouse visual cortex at 50-{micro}m resolution directly from large-volume, segmented nanometer-scale electron microscopy data. The Minnie 65 subvolume of the MICrONS dataset is accurately subdivided into 1,224 50-{micro}m cubic blocks. Each block contains, on average, 40-50 million membrane facets of a highly convoluted and dense cellular structure. Three orthogonal electrode pairs are applied to each isolated block to estimate the three principal components of the conductivity tensor. Quasistatic electric modeling is enabled by an iterative boundary-element fast multipole method (BEM-FMM) under the approximation of non-conducting membranes (DC conductivity). Spatially averaged conductivity values predicted by our framework agree well with prior low-resolution measurements in rats, validating the approach. At the same time, the resulting mesoscale maps reveal pronounced conductivity granularity at 50-100 {micro}m scales as well as significant variations in both radial and tangential directions. These results indicate that mesoscale conductivity heterogeneity could be an intrinsic structural property of the cortex. Limitations and extensions of this study are discussed in detail.

neuroscience↗

Design and Analysis of a Whole Body Non-Contact Electromagnetic Stimulation Device with Field Modulation

This study describes a whole-body, non-contact electromagnetic stimulation device based on the concept of a conventional MRI Radio Frequency (RF) resonating coil, but at a much lower resonant frequency (100-150 kHz), with a field modulation option (0.5-100 Hz) and with an input power of up to 3 kW. Its unique features include a high electric field level within the biological tissue due to the resonance effect and a low power dissipation level, or a low Specific Absorption Rate (SAR), in the body itself. Because of its large resonator volume together with non-contact coupling, the subject may be located anywhere within the coil over a longer period at moderate and safe electric field levels. The electric field effect does not depend on body position within the resonator. However, field penetration is deep anywhere within the body, including the extremities where muscles, bones, and peripheral tissues are mostly affected. A potential clinical application of this device is treatment of chronic pain. Substantial attention is paid to device safety; this includes both AC power safety and exposure of human subjects to electromagnetic fields. In the former case, we employ inductive coupling which eliminates a direct current path from AC power to the coil. Our design enhances overall device safety at any power level, even when operated under higher-power conditions. Human exposure to electromagnetic fields within the coil is evaluated by performing modeling with two independent numerical methods and with an anatomically realistic multi-tissue human phantom. We show that SAR levels within the body correspond to International Electrotechnical Commission (IEC) safety standards when the input power level of the amplifier driver does not exceed 3 kW. We also show that electric field levels generally comply with International Commission on Non-Ionizing Radiation Protection safety standards if the input power level does not exceed 1.5 kW.

bioengineering↗