bioRxiv Science⌕ Search

Biology subjects

Lopez, J. D.

Publications and source records attributed to Lopez, J. D..

7 recordsLinked to original sources

Individual Bird Identification by Modeling Temporal Structure in Bioacoustic Embeddings

O_LIIdentifying individual animals from vocalizations is an emerging research area in computational bioacoustics. This non-invasive approach reduces reliance on physical capture and tagging for wildlife monitoring. Recent advances in this area leverage deep learning and bioacoustic foundation models adapted from species-level classifiers. However, these models typically rely on fixed-window inputs and may not fully capture temporal structure across extended or complex songs, which can contain information relevant to individual discrimination. C_LIO_LIHere, we evaluate whether modeling sequences of pretrained bioacoustic embeddings improves acoustic individual identification. We developed a framework that integrates transfer-learned spectrotemporal representations from BirdNET with a lightweight long short-term memory network. Unlike static baselines that use either the first embedding or an average over all embeddings, our approach processes time-ordered embedding sequences, allowing the classifier to use information distributed across multiple windows. C_LIO_LIWe evaluated the system using 87,865 vocalizations from 352 individuals across seven species. We used four publicly available vocalization datasets with individual-level labels, covering durations from 0.76 s (short calls) to 27.6 s (prolonged songs). Across five random seeds with stratified partitions, the framework achieved mean test accuracies between 93.9% and 98.3% and macro-F1 scores ranging from 93.2% to 98.3%, without data augmentation. The clearest gains over the strongest static baseline were observed for the great tit and the great spotted kiwi, reaching +1.3 and +2.8 percentage points, respectively. C_LIO_LIOur results indicate that the contribution of temporal sequence modeling depends on vocalization structure, rather than providing uniform evidence that chronological order drives performance. The benefit of recurrent aggregation was limited or absent for short calls but evident for long vocalizations with multiple informative windows. By combining bioacoustic foundation models with lightweight recurrent modeling, this approach provides a scalable, CPU-efficient tool for autonomous wildlife monitoring, particularly for species with extended or structurally complex vocalizations. C_LI

ecology↗

Thermal optimized PCR coupled to CRISPR-Cas12a for rapid detection of blaOXA-1 resistance gene

The {beta}-lactams are critically important broad-spectrum antibiotics, widely used as first-line treatments; however, their effectiveness is increasingly compromised by {beta}-lactamase enzymes. Among these, OXA-type enzymes have expanded to over 400 variants and are highly prevalent in Enterobacteriaceae. Current phenotypic and molecular detection tests have long turnaround times or require specialized equipment, respectively. In this study, we optimize a rapid molecular assay combining a PCR with modified thermal ramp rate (TRR) along with CRISPR-Cas12a fluorescence detection for the blaOXA-1gene. Using a commercial DNA Taq polymerase (TRR: 2.2 {degrees}C/s, annealing and extension hold time: 1 s), amplification time was reduced from 80 to 30 min, enabling detection within 50 min (PCR: 30 min; CRISPR: 20 min). With a locally produced enzyme (hold: 10 s), amplification time was 44 min. The assay achieved an analytical sensitivity of 8 CFU/reaction using commercial DNA Taq polymerase. The accelerated PCR:CRISPR workflow delivers results in less than one hour without compromising technical sensitivity (attomoles range), not requiring high technical expertise, and can be implemented in laboratories with basic molecular biology equipment. HighlightsAn optimized thermal gradient can reduce the turnaround time of PCR-based detection tests CRISPR-Cas in addition to the modified PCR can detect a gene target in less than an hour The proposed workflow is suitable for implementation with basic molecular biology equipment

molecular biology↗

Distorting anatomy to test MEG models and metrics

Current flow that gives rise to non-invasive Magnetoencephalographic (MEG) data derives predominantly from pyramidal neurons oriented orthogonal to the cortical surface. The estimate of current flow based on extra-cranial magnetic fields is a well-known ill-posed problem; however, this current distribution must depend on anatomy. In other words, a veridical estimate of current flow should discriminate between true and distorted versions of the brain. Here, we make use of advances in diffeomorphic brain shape modelling to construct a set of parametrically deformable cortical surfaces. We use a latent space of 100 components to construct cortical surfaces that are representative of the population. We show how these geometric distortions can be used to quantify the performance of MEG source reconstruction algorithms and metrics of fit.

neuroscience↗

Quantifying and mitigating recorder-induced variability in ecological acoustic indices

Due to the complexity of soundscapes, Ecological Acoustic indices (EAI) are frequently used as metrics to summarize ecologically meaningful information from audio recordings. Recent technological advances have allowed the rapid development of many audio recording devices with significant hardware/firmware variations among brands, whose effects in calculating EAI have not yet be determined. In this work, we show how recordings of the same landscape with different devices effectively hinder reproducibility and produce contradictory results. To address these issues, we propose a preprocessing pipeline to reduce EAI variability resulting from different hardware without altering the target information in the audio. To this end, we tested eight EAI commonly used in soundscape analyses. We targeted three common cases of variability caused by recorder characteristics: sampling frequency, microphone gain variation, and frequency response. We quantified the difference in the probability density functions of each index among recorders according to the Kullback-Leibler divergence. As a result, our approach reduced up to 75% variations among recorders from different brands (AudioMoth and SongMeter) and identified the conditions in which these devices are comparable. In conclusion, we demonstrated that different devices effectively affect EAI and show how these variations can be mitigated. Graphical Abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=130 SRC="FIGDIR/small/562620v1_ufig1.gif" ALT="Figure 1"> View larger version (38K): org.highwire.dtl.DTLVardef@13defb9org.highwire.dtl.DTLVardef@14597d8org.highwire.dtl.DTLVardef@1f3e795org.highwire.dtl.DTLVardef@1e90f2e_HPS_FORMAT_FIGEXP M_FIG C_FIG HighlightsO_LIAddressing recorder-induced biases in acoustic indices for improved reproducibility. C_LIO_LIProposing an effective method to mitigate recorder-related biases. C_LIO_LIEvaluating pipeline proposed performance via acoustic index distribution analysis. C_LI

bioengineering↗

Magnetic Field Mapping and Correction for Moving OP-MEG

BackgroundOptically pumped magnetometers (OPMs) have made moving, wearable magnetoencephalography (MEG) possible. The OPMs typically used for MEG require a low background magnetic field to operate, which is achieved using both passive and active magnetic shielding. However, the background magnetic field is never truly zero Tesla, and so the field at each of the OPMs changes as the participant moves. This leads to position and orientation dependent changes in the measurements, which manifest as low frequency artefacts in MEG data. ObjectiveWe modelled the spatial variation in the magnetic field and used the model to predict the movement artefact found in a dataset. MethodsWe demonstrate a method for modelling this field with a triaxial magnetometer, then showed that we can use the same technique to predict the movement artefact in a real OPM-based MEG (OP-MEG) dataset. ResultsUsing an 86-channel OP-MEG system, we found that this modelling method maximally reduced the power spectral density of the data by 26.2 {+/-} 0.6 dB at 0 Hz, when applied over 5 s non-overlapping windows. ConclusionThe magnetic field inside our state-of-the art magnetically shielded room can be well described by low-order spherical harmonic functions. We achieved a large reduction in movement noise when we applied this model to OP-MEG data. SignificanceReal-time implementation of this method could reduce passive shielding requirements for OP-MEG recording and allow the measurement of low-frequency brain activity during natural participant movement.

neuroscience↗

Mouth magnetoencephalography: A unique perspective on the human hippocampus

Traditional magnetoencephalographic (MEG) brain imaging scanners consist of a rigid sensor array surrounding the head; this means that they are maximally sensitive to superficial brain structures. New technology based on optical pumping means that we can now consider more flexible and creative sensor placement. Here we explored the magnetic fields generated by a model of the human hippocampus not only across scalp but also at the roof of the mouth. We found that simulated hippocampal sources gave rise to dipolar field patterns with one scalp surface field extremum at the temporal lobe and a corresponding maximum or minimum at the roof of the mouth. We then constructed a fitted dental mould to accommodate an Optically Pumped Magnetometer (OPM). We collected data using a previously validated hippocampal-dependent task to test the empirical utility of a mouth-based sensor, with an accompanying array of left and right temporal lobe OPMs. We found that the mouth sensor showed the greatest task-related theta power change. We also found that, as predicted by the simulations, the mouth sensor was anti-correlated with those on over the temporal lobes. We found that this sensor had a mild effect on the reconstructed power in the hippocampus (~10% change) but that coherence images between the mouth sensor and reconstructed source images showed a global maximum in the right hippocampus. We conclude that augmenting a scalp-based MEG array with sensors in the mouth shows unique promise for both basic scientists and clinicians interested in interrogating the hippocampus.

neuroscience↗

Sedation modulates fronto-temporal predictive coding circuits and the double surprise acceleration effect

Two important theories in cognitive neuroscience are predictive coding and the global workspace theory. A key research task is to understand how these two theories relate to one another, and particularly, how the brain transitions from a predictive early state to the eventual engagement of a brain-scale state (the global workspace). To address this question, we present a source-localisation of EEG responses evoked by the local-global task - an experimental paradigm that engages a predictive hierarchy, which encompasses the global workspace. The results of our source reconstruction suggest three-phases of processing. The first phase involves the sensory (here auditory) regions of the superior temporal lobe and predicts sensory regularities over a short timeframe (as per the local effect). The third phase is brain-scale, involving inferior frontal, as well as inferior and superior parietal regions; consistent with a global neuronal workspace (as per the global effect). Crucially, our analysis suggests that there is an intermediate (second) phase, involving modulatory interactions between inferior frontal and superior temporal regions. Furthermore, sedation with propofol reduces modulatory interactions in the second phase. This selective effect is consistent with a predictive coding explanation of sedation, with propofol acting on descending predictions of the precision of prediction errors; thereby constraining access to the global neuronal workspace.

neuroscience↗