bioRxiv Science⌕ Search

Biology subjects

LoGrande, N. T.

Publications and source records attributed to LoGrande, N. T..

5 recordsLinked to original sources

Synergistic therapeutic effects of endolysin BNT331 and a Lactobacillus crispatus consortium in a human vagina chip model of bacterial vaginosis

Bacterial vaginosis (BV) is a vaginal infection caused by an imbalance in the vaginal microbiome characterized by a decrease in healthy bacteria dominated by Lactobacillus crispatus along with a concomitant increase in dysbiotic bacteria, such as Gardnerella. Current treatments commonly fail to fully eradicate BV, and the lack of more effective therapies is due in part to the absence of relevant human models. Here, we used a human vagina-on-a-chip (Vagina Chip) microfluidic culture device that has been previously shown to faithfully recapitulate the human vaginal microenvironment as well as the inflammatory and injurious effects of G. vaginalis to test the therapeutic efficacy of a consortium of L. crispatus alone or in combination with endolysin BNT331, which specifically targets and lyses Gardnerella. These studies revealed that when L. crispatus was added alone, it suppressed inflammation even though it failed to engraft or displace the G. vaginalis bacteria. In contrast, BNT331 effectively killed Gardnerella in dysbiotic Vagina Chip. Importantly, the combined administration of both treatments resulted in restoration of a healthier vaginal microenvironment, as indicated by higher engraftment of L. crispatus on-chip, inhibition of G. vaginalis, and a reduction in inflammation. Similar effects of this combined treatment were observed when administered to Vagina Chips infected with vaginal swab samples from BV patients. These data suggest that combination of a live biotherapeutic product composed of a L. crispatus consortium with a potent antimicrobial agent that targets G. vaginalis, such as BNT331, may offer an effective therapeutic strategy for patients with BV. One Sentence SummaryEndolysin BNT331 combined with Lactobacillus crispatus reduces bacterial load and suppresses inflammation in a human vagina chip model of bacterial vaginosis.

pathology↗

Endothelial CLK2 as a therapeutic target for acute radiation syndrome

Damage to the vascular endothelium is a major contributor to acute radiation injury in multiple organs that underlies acute radiation syndrome (ARS), yet there are no FDA-approved radiation countermeasures targeting endothelial cells. Use of kinome-scale CRISPR screens performed in cultured human vascular endothelial cells isolated from different organs identified CLK2 as a potential radioprotective target. Pharmacological inhibition of CLK2 using TG003 and Cirtuvivint protected these endothelial cells against radiation injury and reversed its effects across the transcriptome and phospho-proteome. Human Organ Chip models of human intestine and lung that contain organ-specific epithelium and microvascular endothelium faithfully replicated clinical features of ARS when exposed to radiation, which were prevented when treated with CLK2 inhibitors. Thus, CLK2 inhibitors may represent a new class of radiation countermeasure drugs that can protect multiple organs against radiation-induced toxicities in patients with ARS.

molecular biology↗

Organ Chips with integrated multifunctional sensors enable continuous metabolic monitoring at controlled oxygen levels

Despite remarkable advances in Organ-on-a-chip (Organ Chip) microfluidic culture technology, recreating tissue-relevant physiological conditions, such as the region-specific oxygen concentrations, remains a formidable technical challenge, and analysis of tissue functions is commonly carried out using one analytical technique at a time. Here, we describe two-channel Organ Chip microfluidic devices fabricated from polydimethylsiloxane and gas impermeable polycarbonate materials that are integrated with multiple sensors, mounted on a printed circuit board and operated using a commercially available Organ Chip culture instrument. The novelty of this system is that it enables the recreation of physiologically relevant tissue-tissue interfaces and oxygen tension as well as non-invasive continuous measurement of transepithelial electrical resistance, oxygen concentration and pH, combined with simultaneous analysis of cellular metabolic activity (ATP/ADP ratio), cell morphology, and tissue phenotype. We demonstrate the reliable and reproducible functionality of this system in living human Gut and Liver Chip cultures. Changes in tissue barrier function and oxygen tension along with their functional and metabolic responses to chemical stimuli (e.g., calcium chelation, oligomycin) were continuously and noninvasively monitored on-chip for up to 23 days. A physiologically relevant microaerobic microenvironment that supports co-culture of human intestinal cells with living Lactococcus lactis bacteria also was demonstrated in the Gut Chip. The integration of multi-functional sensors into Organ Chips provides a robust and scalable platform for the simultaneous, continuous, and non-invasive monitoring of multiple physiological functions that can significantly enhance the comprehensive and reliable evaluation of engineered tissues in Organ Chip models in basic research, preclinical modeling, and drug development.

bioengineering↗

Mucus production, host-microbiome interactions, hormone sensitivity, and innate immune responses modeled in human endo- and ecto-cervix chips

Modulation of mucus production by the human endo- and ecto-cervical epithelium by steroid hormones and associated interactions with commensal microbiome play a central role in the physiology and pathophysiology of the female reproductive tract. However, most of our knowledge about these interactions is based on results from animal studies or in vitro models that fail to faithfully mimic the mucosal environment of the human cervix. Here we describe microfluidic organ-on-a-chip (Organ Chip) models of the human cervical mucosa that recreate the cervical epithelial-stromal interface with a functional epithelial barrier and produce abundant mucus that has compositional, biophysical, and hormone-responsive properties similar to the living cervix. Application of continuous fluid flow to chips lined with primary human cervical epithelial cells from a commercial source that contained a mixture of primary human ecto- and endo-cervical epithelial cells promoted preferential expression of the ecto-cervical phenotype, whereas use of periodic flow including periods of stasis induced endo-cervical specialization. When the periodic flow Cervix Chips were co-cultured with living Lactobacillus crispatus and Gardnerella vaginalis bacterial communities to respectively mimic the effects of human host interactions with optimal (healthy) or non-optimal (dysbiotic) microbiome associated with an ascending infection in the female reproductive tract, significant differences in tissue innate immune responses, barrier function, cell viability and protein profile, and mucus composition were detected reminiscent of those observed in vivo. Thus, these Organ Chip models of human cervix provide a physiologically relevant experimental in vitro model to study cervical mucus physiology and its role in human host-microbiome interactions as well as a potential preclinical testbed for development of therapeutic interventions to enhance womens health.

bioengineering↗

Vaginal microbiome-host interactions modeled in a human vagina-on-a-chip

BackgroundA dominance of non-iners Lactobacillus species in the vaginal microbiome is optimal and strongly associated with gynecological and obstetric health, while the presence of diverse obligate or facultative anaerobic bacteria and a paucity in Lactobacillus species, similar to communities found in bacterial vaginosis (BV), is considered non-optimal and associated with adverse health outcomes. Various therapeutic strategies are being explored to modulate the composition of the vaginal microbiome; however, there is no human model that faithfully reproduces the vaginal epithelial microenvironment for preclinical validation of potential therapeutics or testing hypotheses about vaginal epithelium-microbiome interactions. ResultsHere, we describe an organ-on-a-chip (Organ Chip) microfluidic culture model of the human vaginal mucosa (Vagina Chip) that is lined by hormone-sensitive, primary vaginal epithelium interfaced with underlying stromal fibroblasts, which sustains a low physiological oxygen concentration in the epithelial lumen. We show that the Vagina Chip can be used to assess colonization by optimal L. crispatus consortia as well as non-optimal Gardnerella vaginalis-containing consortia, and to measure associated host innate immune responses. Co-culture of the L. crispatus consortia was accompanied by maintenance of epithelial cell viability, accumulation of D- and L-lactic acid, maintenance of a physiologically relevant low pH, and down regulation of proinflammatory cytokines. In contrast, co-culture of G. vaginalis-containing consortia in the Vagina Chip resulted in epithelial cell injury, a rise in pH, and upregulation of proinflammatory cytokines. ConclusionThis study demonstrates the potential of applying human Organ Chip technology to create a preclinical model of the human vaginal mucosa that can be used to better understand interactions between the vaginal microbiome and host tissues, as well as to evaluate the safety and efficacy of live biotherapeutics products.

microbiology↗