bioRxiv Science⌕ Search

Biology subjects

Liberale, C.

Publications and source records attributed to Liberale, C..

4 recordsLinked to original sources

Aberration correction in long GRIN lens-based microendoscopes for extended field-of-view two-photon imaging in deep brain regions

Two-photon (2P) fluorescence imaging through gradient index (GRIN) lens-based endoscopes is fundamental to investigate the functional properties of neural populations in deep brain circuits. However, GRIN lenses have intrinsic optical aberrations, which severely degrade their imaging performance. GRIN aberrations decrease the signal-to-noise ratio (SNR) and spatial resolution of fluorescence signals, especially in lateral portions of the field-of-view (FOV), leading to restricted FOV and smaller number of recorded neurons. This is especially relevant for GRIN lenses of several millimeters in length, which are needed to reach the deeper regions of the rodent brain. We have previously demonstrated a novel method to enlarge the FOV and improve the spatial resolution of 2P microendoscopes based on GRIN lenses of length < 4.1 mm (Antonini et al. eLife 2020). However, previously developed microendoscopes were too short to reach the most ventral regions of the mouse brain. In this study, we combined optical simulations with fabrication of aspherical polymer microlenses through three-dimensional (3D) microprinting to correct for optical aberrations in long (length > 6 mm) GRIN lens-based microendoscopes (diameter, 500 {micro}m). Long corrected microendoscopes had improved spatial resolution, enabling imaging in significantly enlarged FOVs. Moreover, using synthetic calcium data we showed that aberration correction enabled detection of cells with higher SNR of fluorescent signals and decreased cross-contamination between neurons. Finally, we applied long corrected microendoscopes to perform large-scale and high precision recordings of calcium signals in populations of neurons in the olfactory cortex, a brain region laying approximately 5 mm from the brain surface, of awake head-tethered mice. Long corrected microendoscopes are powerful new tools enabling population imaging with unprecedented large FOV and high spatial resolution in the most ventral regions of the mouse brain.

neuroscience↗

Lipid Droplets Fuel Small Extracellular Vesicle Biogenesis

Despite an increasing gain of knowledge regarding small extracellular vesicle (sEV) composition and functions in cell-cell communication, the mechanism behind their biogenesis remains unclear. Here, we revealed for the first time that the sEV biogenesis and release into the microenvironment are tightly connected with another important organelle: Lipid Droplets (LD). We have observed this correlation using different human cancer cell lines as well as patient-derived colorectal cancer stem cells (CR-CSCs). Our results showed that the use of external stimuli such as radiation, pH, hypoxia, or lipid interfering drugs, known to affect the LD content, had a similar effect in terms of sEV secretion. Additional validations were brought using multiple omics data, at the mRNA and protein levels. Altogether, the possibility to fine-tune sEV biogenesis by targeting LDs, could have a massive impact on the amount, the cargos and the properties of those sEVs, paving the way for new clinical perspectives. Significance Statement

cancer biology↗

Extended field-of-view ultrathin microendoscopes for high-resolution two-photon imaging with minimal invasiveness in awake mice

Imaging neuronal activity with high and homogeneous spatial resolution across the field-of-view (FOV) and limited invasiveness in deep brain regions is fundamental for the progress of neuroscience, yet is a major technical challenge. We achieved this goal by correcting optical aberrations in gradient index lens-based ultrathin ([&le;] 500 {micro}m) microendoscopes using aspheric microlenses generated through 3D-microprinting. Corrected microendoscopes had extended FOV (eFOV) with homogeneous spatial resolution for two-photon fluorescence imaging and required no modification of the optical set-up. Synthetic calcium imaging data showed that, compared to uncorrected endoscopes, eFOV-microendoscopes led to improved signal-to-noise ratio and more precise evaluation of correlated neuronal activity. We experimentally validated these predictions in awake head-fixed mice. Moreover, using eFOV-microendoscopes we demonstrated cell-specific encoding of behavioral state-dependent information in distributed functional subnetworks in a primary somatosensory thalamic nucleus. eFOV-microendoscopes are, therefore, small-cross-section ready-to-use tools for deep two-photon functional imaging with unprecedentedly high and homogeneous spatial resolution.

neuroscience↗

Extended field-of-view ultrathin microendoscopes with built-in aberration correction for high-resolution imaging with minimal invasiveness

We present a novel approach to correct optical aberrations in ultrathin gradient-index rod lens-based endoscopes using microfabricated aspherical lenses. Corrected microendoscopes have up to 9 folds larger field-of-view compared to uncorrected probes. Using extended field-of-view (eFOV) microendoscopes, we report two-photon imaging of GCaMP6 signals in the mouse hippocampus in vivo with unprecedented combination of high spatiotemporal resolution and minimal invasiveness.

neuroscience↗