Evaluating the predictive accuracy of ion channel models using data from multiple experimental designs

Mathematical models are increasingly being relied upon to provide quantitatively accurate predictions of cardiac electrophysiology. Many such models concern the behaviour of particular subcellular components (namely, ion channels) which, together, allow the propagation of electrical signals through heart-muscle tissue--namely, the firing of action potentials. In particular, IKr, a voltage-sensitive potassium ion-channel current, is of interest owing to its central pores propensity for blockage by various small molecules. We use newly collected data obtained from an ensemble of voltage-clamp experiments to validate the predictive accuracy of various dynamical models of IKr. To do this, we fit models to each protocol individually, and quantify the error in the resultant model predictions. This allows the comparison of predictive accuracy for IKr models under a diverse collection of previously unexplored dynamics. Our results highlight heterogeneity between parameter estimates obtained from different cells, suggesting the presence of latent effects not yet accounted for in our models. This heterogeneity has a significant impact on our parameter estimates and suggests routes for model improvement.

biophysics↗

A range of voltage-clamp protocol designs for rapid capture of hERG kinetics

We provide details of a series of short voltage-clamp protocols designed for gathering a large amount of information on hERG (Kv11.1) ion channel gating. The protocols have a limited number of steps and consist only of steps and ramps, making them easy to implement on any patch clamp setup, including automated platforms. The primary objective is to assist with parameterisation, selection and refinement of mathematical models of hERG gating. We detail a series of manual and automated model-driven designs, together with an explanation of their rationale and design criteria. Although the protocols are intended to study hERG1a currents, the approaches could be easily extended and generalised to other ion channel currents.

biophysics↗

Resolving artefacts in voltage-clamp experiments with computational modelling: an application to fast sodium current recordings

Cellular electrophysiology is the foundation of many fields, from basic science in neurology, cardiology, oncology to safety critical applications for drug safety testing, clinical phenotyping, etc. Patch-clamp voltage clamp is the gold standard technique for studying cellular electrophysiology. Yet, the quality of these experiments is not always transparent, which may lead to erroneous conclusions for studies and applications. Here, we have developed a new computational approach that allows us to explain and predict the experimental artefacts in voltage-clamp experiments. The computational model captures the experimental procedure and its inadequacies, including: voltage offset, series resistance, membrane capacitance and (imperfect) amplifier compensations, such as series resistance compensation and supercharging. The computational model was validated through a series of electrical model cell experiments. Using this computational approach, the artefacts in voltage-clamp experiments of cardiac fast sodium current, one of the most challenging currents to voltage clamp, were able to be resolved and explained through coupling the observed current and the simulated membrane voltage, including some typically observed shifts and delays in the recorded currents. We further demonstrated that the typical way of averaging data for current-voltage relationships would lead to biases in the peak current and shifts in the peak voltage, and such biases can be in the same order of magnitude as those differences reported for disease-causing mutations. Therefore, the presented new computational pipeline will provide a new standard of assessing the voltage-clamp experiments and interpreting the experimental data, which may be able to rectify and provide a better understanding of ion channel mutations and other related applications.

systems biology↗

Optimal experimental designs for characterising ion channel gating by filling the phase-voltage space of model dynamics

Voltage-clamp waveforms are imposed in the patch-clamp electrophysiology technique to provoke ion currents, the particular waveform that is used is known as the voltage-clamp protocol. Designing protocols to probe and quantify how gating for a particular ion channel occurs has typically been done manually and results in a suite of long protocols. It is desirable to gain the same, or even more, information in a shorter time, and also to automate the process of designing these protocols. In this paper we introduce a new optimal experimental design objective for ion channel characterisation, which involves considering a 3-dimensional phase space for the channel states combined with the voltage, using room-temperature hERG/Kv11.1 currents as an example. A range of designs are proposed, the best of which visits 82% of the discretised phase-voltage space in a 9 second protocol. This new protocol design strategy results in a simulated current visiting a wide range of channel gating states, at a wide variety of voltages, and we therefore expect these designs to be very useful in characterising ion currents, parameterising models, as well as being a challenging test of assumptions made about ion channel gating.

biophysics↗

The impact of uncertainty in hERG binding mechanism on in silico predictions of drug-induced proarrhythmic risk

Background and PurposeDrug-induced reduction of the rapid delayed rectifier potassium current carried by the human Ether-a-go-go-Related Gene (hERG) channel is associated with increased risk of arrhythmias. Recent updates to drug safety regulatory guidelines attempt to capture each drugs hERG binding mechanism by combining in vitro assays with in silico simulations. In this study, we investigate the impact on in silico proarrhythmic risk predictions due to uncertainty in the hERG binding mechanism and physiological hERG current model. Experimental ApproachPossible pharmacological binding models were designed for the hERG channel to account for known and postulated small molecule binding mechanisms. After selecting a subset of plausible binding models for each compound through calibration to available voltage-clamp electrophysiology data, we assessed their effects, and the effects of different physiological models, on proarrhythmic risk predictions. Key ResultsFor some compounds, multiple binding mechanisms can explain the same data produced under the safety testing guidelines, which results in different inferred binding rates. This can result in substantial uncertainty in the predicted torsade risk, which often spans more than one risk category. By comparison, we found that the effect of a different hERG physiological current model on risk classification was subtle. Conclusion and ImplicationsThe approach developed in this study assesses the impact of uncertainty in hERG binding mechanisms on predictions of drug-induced proarrhythmic risk. For some compounds, these results imply the need for additional binding data to decrease uncertainty in safety-critical applications.

biophysics↗

Model-driven optimal experimental design for calibrating cardiac electrophysiology models

Models of the cardiomyocyte action potential (AP) have contributed immensely to the understanding of heart function, pathophysiology, and the origin of heart rhythm disturbances. However, AP models are nonlinear, complex, and can contain more than a hundred differential equations, making them difficult to parameterise. Therefore, cellular cardiac models have been limited to describing average cell dynamics, when cell-specific models would be ideal to uncover inter-cell variability but are too experimentally challenging to be achieved. Here, we focus on automatically designing experimental protocols that allow us to better identify cell-specific maximum conductance values for each major current type--optimal experimental designs--for both voltage-clamp and current-clamp experiments. We show that optimal designs are able to perform better than many of the existing experiment designs in the literature in terms of identifying model parameters and hence model predictive power. For cardiac cellular electrophysiology, this approach will allow researchers to define their hypothesis of the dynamics of the system and automatically design experimental protocols that will result in theoretically optimal designs.

systems biology↗

Leak current, even with gigaohm seals, can cause misinterpretation of stem-cell derived cardiomyocyte action potential recordings

Human induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) have become an essential tool to study arrhythmia mechanisms. Much of the foundational work on these cells, and the computational models built from the resultant data, has overlooked the contribution of seal-leak current on the immature and heterogeneous phenotype that has come to define these cells. Here, we use in silico and in vitro studies to demonstrate how seal-leak current depolarises action potentials (APs), substantially affecting their morphology, even with seal resistances (Rseal) above 1 G{Omega}. We show that compensation of this leak current is difficult due to challenges with recording accurate measures of Rseal during an experiment. Using simulation, we show that Rseal measures: 1) change during an experiment, invalidating the use of pre-rupture values, and 2) are polluted by the presence of transmembrane currents at every voltage. Finally, we posit the background sodium current in baseline iPSC-CM models imitates the effects of seal-leak current and is increased to a level that masks the effects of seal-leak current on iPSC-CMs. Based on these findings, we make three recommendations to improve iPSC-CM AP data acquisition, interpretation, and model-building. Taking these recommendations into account will improve our understanding of iPSC-CM physiology and the descriptive ability of models built from such data. Key pointsO_LIHuman induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) are an essential tool in the study of cardiac arrhythmia mechanisms. C_LIO_LITheir immature and heterogeneous action potential phenotype complicates the interpretation of experimental data, and has slowed their acceptance in industry and academia. C_LIO_LIWe suggest that a leak current caused by an imperfect pipette-membrane seal during single-cell patch-clamp experiments is partly responsible for inducing this phenotype. C_LIO_LIUsing in vitro experiments and computational modelling, we show that this seal-leak current affects iPSC-CM AP morphology, even under ideal experimental conditions. C_LIO_LIBased on these findings, we make recommendations that should be considered when interpreting, analysing and fitting iPSC-CM data. C_LI

physiology↗

Accounting for variability in ion current recordings using a mathematical model of artefacts in voltage-clamp experiments

Mathematical models of ion channels, which constitute indispensable components of action potential models, are commonly constructed by fitting to whole-cell patch-clamp data. In a previous study we fitted cell-specific models to hERG1a (Kv11.1) recordings simultaneously measured using an automated high-throughput system, and studied cell-cell variability by inspecting the resulting model parameters. However, the origin of the observed variability was not identified. Here we study the source of variability by constructing a model that describes not just ion current dynamics, but the entire voltage-clamp experiment. The experimental artefact components of the model include: series resistance, membrane and pipette capacitance, voltage offsets, imperfect compensations made by the amplifier for these phenomena, and leak current. In this model, variability in the observations can be explained by either cell properties, measurement artefacts, or both. Remarkably, by assuming that variability arises exclusively from measurement artefacts, it is possible to explain a larger amount of the observed variability than when assuming cell-specific ion current kinetics. This assumption also leads to a smaller number of model parameters. This result suggests that most of the observed variability in patch-clamp data measured under the same conditions is caused by experimental artefacts, and hence can be compensated for in post-processing by using our model for the patch-clamp experiment. This study has implications for the question of the extent to which cell-cell variability in ion channel kinetics exists, and opens up routes for better correction of artefacts in patch-clamp data.

biophysics↗

Rapid characterisation of hERG channel kinetics II: temperature dependence

Ion channel behaviour can depend strongly on temperature, with faster kinetics at physiological temperatures leading to considerable changes in currents relative to room temperature. These temperature-dependent changes in voltage-dependent ion channel kinetics (rates of opening, closing and inactivating) are commonly represented with Q10 coefficients or an Eyring relationship. In this paper we assess the validity of these representations by characterising channel kinetics at multiple temperatures. We focus on the hERG channel, which is important in drug safety assessment and commonly screened at room temperature, so that results require extrapolation to physiological temperature. In Part I of this study we established a reliable method for high-throughput characterisation of hERG1a (Kv11.1) kinetics, using a 15 second information-rich optimised protocol. In this Part II, we use this protocol to study the temperature dependence of hERG kinetics using CHO cells over-expressing hERG1a on the Nanion SyncroPatch 384PE, a 384-well automated patch clamp platform, with temperature control. We characterise the temperature dependence of hERG gating by fitting the parameters of a mathematical model of hERG kinetics to data obtained at five distinct temperatures between 25 and 37 {degrees}C, and validate the models using different protocols. Our models reveal that activation is far more temperature sensitive than inactivation, and we observe that the temperature dependency of the kinetic parameters is not represented well by Q10 coefficients: it broadly follows a generalised, but not the standardly-used, Eyring relationship. We also demonstrate that experimental estimations of Q10 coefficients are protocol-dependent. Our results show that a direct fit using our 15 second protocol best represents hERG kinetics at any given temperature, and suggests that predictions from the Generalised Eyring theory may be preferentially used if no experimentally-derived data are available.\n\nStatement of SignificanceIon channel currents are highly sensitive to temperature changes. Yet because many experiments are performed more easily at room temperature, it is common to extrapolate findings to physiological temperatures through the use of Q10 coefficients or Eyring rate theory. By applying short, information-rich protocols that we developed in Part I of this study we identify how kinetic parameters change over temperature. We find that the commonly-used Q10 and Eyring formulations are incapable of describing the parameters temperature dependence, a more Generalised Eyring relationship works well, but remeasuring kinetics and refitting a model is optimal. The findings have implications for the accuracy of the many applications of Q10 coefficients in electrophysiology, and suggest that care is needed to avoid misleading extrapolations in their many scientific and industrial pharmaceutical applications.

biophysics↗

Rapid characterisation of hERG channel kinetics I: using an automated high-throughput system

Predicting how pharmaceuticals may affect heart rhythm is a crucial step in drug-development, and requires a deep understanding of a compounds action on ion channels. In vitro hERG-channel current recordings are an important step in evaluating the pro-arrhythmic potential of small molecules, and are now routinely performed using automated high-throughput patch clamp platforms. These machines can execute traditional voltage clamp protocols aimed at specific gating processes, but the array of protocols needed to fully characterise a current is typically too long to be applied in a single cell. Shorter high-information protocols have recently been introduced which have this capability, but they are not typically compatible with high-throughput platforms. We present a new high-information 15 s protocol to characterise hERG (Kv11.1) kinetics, suitable for both manual and high-throughput systems. We demonstrate its use on the Nanion SyncroPatch 384PE, a 384 well automated patch clamp platform, by applying it to CHO cells stably expressing hERG1a. From these recordings we construct 124 cell-specific variants/parameterisations of a hERG model at 25 {degrees}C. A further 8 independent protocols are run in each cell, and are used to validate the model predictions. We then combine the experimental recordings using a hierarchical Bayesian model, which we use to quantify the uncertainty in the model parameters, and their variability from cell to cell, which we use to suggest reasons for the variability. This study demonstrates a robust method to measure and quantify uncertainty, and shows that it is possible and practical to use high-throughput systems to capture full hERG channel kinetics quantitatively and rapidly.\n\nStatement of SignificanceWe present a method for high-throughput characterisation of hERG potassium channel kinetics, via fitting a mathematical model to results of over one hundred single cell patch clamp measurements collected simultaneously on an automated voltage clamp platform. The automated patch clamp data are used to parameterise a mathematical ion channel model fully, opening a new era of automated and rapid development of mathematical models from quick and cheap experiments. The method also allows ample data for independent validation of the models and enables us to study experimental variability and propose its origins. In future the method can be applied to characterise changes to hERG currents in different conditions, for instance at different temperatures (see Part II of the study) or under mutations or the action of pharmaceuticals; and should be easily adapted to study many other currents.

biophysics↗