bioRxiv ScienceSearch

Biology subjects

Krishnan, L.

Publications and source records attributed to Krishnan, L..

2 recordsLinked to original sources

Effects of BMP-2 dose and delivery of microvascular fragments on healing of bone defects with concomitant volumetric muscle loss

Traumatic composite bone-muscle injuries, such as open fractures, often require multiple surgical interventions and still typically result in long-term disability. Clinically, a critical indicator of composite injury severity is vascular integrity; vascular damage alone is sufficient to assign an open fracture to the most severe category. Challenging bone injuries are often treated with bone morphogenetic protein 2 (BMP-2), an osteoinductive growth factor, delivered on collagen sponge. Previous studies in a composite defect model found that a minimally bridging dose in the segmental defect model was unable to overcome concomitant muscle damage, but the effect of BMP dose on composite injuries has not yet been studied. Here, we test the hypotheses that BMP-2-mediated functional regeneration of composite extremity injuries is dose dependent and can be further enhanced via co-delivery of adipose-derived microvascular fragments (MVF), which have been previously shown to increase tissue vascular volume. Although MVF treatment did not improve healing outcomes, we observed a significant BMP-2 dose-dependent increase in regenerated bone volume and biomechanical properties. While high dose BMP-2 delivery can induce heterotopic ossification (HO) and increased inflammation, the maximum 10 g dose used in this study did not result in HO and was associated with a lower circulating inflammatory cytokine profile than the low dose (2.5 g) group. These data support the potential benefits of an increased, though still moderate, BMP-2 dose for treatment of bone defects with concomitant muscle damage. Future work to improve vascularization may further improve healing.

bioengineering

Wireless Implantable Sensor For Non-Invasive, Longitudinal Quantification Of Axial Strain Across Rodent Long Bone Defects

Bone development, maintenance, and regeneration are remarkably sensitive to mechanical cues. Consequently, mechanical stimulation has long been sought as a putative target to promote endogenous healing after fracture. Given the transient nature of bone repair, tissue-level mechanical cues evolve rapidly over time after injury and are challenging to measure non-invasively. The objective of this work was to develop and characterize an implantable strain sensor for non-invasive monitoring of axial strain across a rodent femoral defect during functional activity. Herein, we present the design, characterization, and in vivo demonstration of the devices capabilities for quantitatively interrogating physiological dynamic strains during bone regeneration. Ex vivo experimental characterization of the device showed that it exceeded the technical requirements for sensitivity, signal resolution, and electromechanical stability. The digital telemetry minimized power consumption, enabling long-term intermittent data collection. Devices were implanted in a rat 6 mm femoral segmental defect model and after three days, data were acquired wirelessly during ambulation and synchronized to corresponding radiographic videos, validating the ability of the sensor to non-invasively measure strain in real-time. Lastly, in vivo strain measurements were utilized in a finite element model to estimate the strain distribution within the defect region. Together, these data indicate the sensor is a promising technology to quantify local tissue mechanics in a specimen specific manner, facilitating more detailed investigations into the role of the mechanical environment in dynamic skeletal healing and remodeling.

bioengineering