bioRxiv Science⌕ Search

Biology subjects

Kersebaum, K.-C.

Publications and source records attributed to Kersebaum, K.-C..

2 recordsLinked to original sources

A calibration protocol for soil-crop models aimed at reducing prediction error and inter-model variability

Process-based soil-crop models are widely used in agronomic research. They are major tools for evaluating climate change impact on crop production. Multi-model simulation studies show a wide diversity of results among models, implying that simulation results are very uncertain. A major path to improving simulation results is to propose improved calibration practices that are widely applicable. This study proposes an innovative generic calibration protocol. The two major innovations concern the treatment of multiple output variables and the choice of parameters to estimate, both of which are based on standard statistical procedure adapted to the particularities of soil-crop models. The protocol performed well in a challenging artificial-data test. The protocol is formulated so as to be applicable to a wide range of models and data sets. If widely adopted, it could substantially reduce model error and inter-model variability, and thus increase confidence in soil-crop model simulations.

plant biology↗

Calibration of crop phenology models: Going beyond recommendations

A major effect of environment on crops is through crop phenology, and therefore, the capacity to predict phenology for new environments is important. Mechanistic crop models are a major tool for such predictions, but calibration of crop phenology models is difficult and there is no consensus on the best approach. Here we propose an original, detailed approach, a protocol, for calibration of such models. The protocol covers all the steps in the calibration work-flow, namely choice of default parameter values, choice of objective function, choice of parameters to estimate from the data, calculation of optimal parameter values and diagnostics. The major innovation is in the choice of which parameters to estimate from the data, which combines expert knowledge and data-based model selection. First, almost additive parameters are identified and estimated. This should make bias (average difference between observed and simulated values) nearly zero. These are "obligatory" parameters, that will definitely be estimated. Then candidate parameters are identified, which are parameters likely to explain the remaining discrepancies between simulated and observed values. A candidate is only added to the list of parameters to estimate if it leads to a reduction in BIC (Bayesian Information Criterion), which is a model selection criterion. A second original aspect of the protocol is the specification of documentation for each stage of the protocol. The protocol was applied by 19 modeling teams to three data sets for wheat phenology. All teams first calibrated their model using their "usual" calibration approach, so it was possible to compare usual and protocol calibration. Evaluation of prediction error was based on data from sites and years not represented in the training data. Compared to usual calibration, calibration following the new protocol reduced the variability between modeling teams by 22% and significantly reduced prediction error.

plant biology↗