bioRxiv ScienceSearch

Biology subjects

Jary, A.

Publications and source records attributed to Jary, A..

2 recordsLinked to original sources

Neutralization heterogeneity of United Kingdom and South-African SARS CoV-2 variants in BNT162b2-vaccinated or convalescent COVID-19 healthcare workers

There are concerns about neutralizing antibodies (NAb) potency against the newly emerged VOC202012/01 (UK) and 501Y.V2 (SA) SARS-CoV-2 variants in mRNA-vaccinated subjects and in recovered COVID-19 patients. We used a viral neutralization test with a strict 100% neutralizing criterion on UK and SA clinical isolates in comparison with a globally distributed D614G SARS-CoV-2 strain. In two doses BNT162b2-vaccinated healthcare workers (HCW), despite heterogeneity in neutralizing capacity against the three SARS-CoV-2 strains, most of the sera harbored at least a NAb titer [≥] 1:10 suggesting a certain humoral protection activity either on UK or SA variants. However, six months after mild forms of COVID-19, an important proportion of HCW displayed no neutralizing activity against SA strain. This result supports strong recommendations for vaccination of previously infected subjects.

microbiology

Multicenter comparison of the Cobas 6800 system with the RealStar RT-PCR kit for the detection of SARS-CoV-2

BackgroundRT-PCR testing is crucial in the diagnostic of SARS-CoV-2 infection. The use of reliable and comparable PCR assays is a cornerstone to allow use of different PCR assays depending on the local equipment. In this work, we provide a comparison of the Cobas(R) (Roche) and the RealStar(R) assay (Altona). MethodsAssessment of the two assays was performed prospectively in three reference Parisians hospitals, using 170 clinical samples. They were tested with the Cobas(R) assay, selected to obtain a distribution of cycle threshold (Ct) as large as possible, and tested with the RealStar assay with three largely available extraction platforms: QIAsymphony (Qiagen), MagNAPure (Roche) and NucliSENS-easyMag (BioMerieux). ResultsOverall, the agreement (positive for at least one gene) was 76%. This rate differed considerably depending on the Cobas Ct values for gene E: below 35 (n = 91), the concordance was 99%. Regarding the positive Ct values, linear regression analysis showed a determination correlation (R2) of 0.88 and the Deming regression line revealed a strong correlation with a slope of 1.023 and an intercept of -3.9. Bland-Altman analysis showed that the mean difference (Cobas(R) minus RealStar(R)) was + 3.3 Ct, with a SD of + 2.3 Ct. ConclusionsIn this comparison, both RealStar(R) and Cobas(R) assays provided comparable qualitative results and a high correlation when both tests were positive. Discrepancies exist after 35 Ct and varied depending on the extraction system used for the RealStar(R) assay, probably due to a low viral load close to the detection limit of both assays.

microbiology