bioRxiv Science⌕ Search

Biology subjects

Jacobs, P.

Publications and source records attributed to Jacobs, P..

5 recordsLinked to original sources

Unsupervised anomaly detection for tumor delineation in a preclinical model of glioblastoma using CEST MRI

IntroductionGlioblastoma is characterized by heterogeneous tumor characteristics and infiltrative tumor boundaries, making accurate delineation difficult with extensive manual annotations. Chemical exchange saturation transfer (CEST) is a non-invasive MRI technique used for in vivo assessment of metabolic and macromolecular information through a Z-spectrum. CEST may provide insight into metabolic changes present in early-stage disease that are not visible in routine clinical imaging, thereby improving tumor delineation. In this work, we use an unsupervised anomaly detection (UAD) strategy to learn the distribution of features present in Z-spectra of healthy tissue and capture their deviations in pathology, foregoing the need for extensive labels. The approach leverages the metabolic information provided by CEST to improve the detection and delineation of glioblastoma and inform further treatment planning. MethodsA 1D convolutional autoencoder (CAE) was implemented to reconstruct Z-spectra from individual tissue voxels. The network was trained on Z-spectra acquired at 9.4T from healthy Sprague-Dawley rats and tested on data acquired from F98 glioma-bearing rats post Gd-administration. For baseline comparisons, Isolation Forest and Local Outlier Factor, which have shown success in anomaly detection, were implemented. For the CAE, our anomaly score was determined to be the mean squared reconstruction error. To facilitate clinical translation and evaluate the robustness of our model for under sampled Z-spectra, acceleration factors of 2x and 7x were performed with two sampling schemes: uniformly skipping frequency offsets and selecting offsets based on feature importance identified by Shapley value analysis and Integrated Gradients (IG). Binarization was performed by determining an optimal anomaly threshold, followed by comparison to ground truth tumor masks. Metrics related to model performance were assessed for baseline anomaly detectors on the fully sampled dataset and for the CAE on fully and under sampled datasets. ResultsThe best baseline anomaly detector was Isolation Forest, with an ROC-AUC of 0.967 and an F1-score of 0.584. Our method, the CAE, accurately reconstructed Z-spectral features, achieving Dice scores of up to 0.72 and outperforming the baseline model with an ROC-AUC of 0.968 and F1-score of 0.642. This model performance remained robust across sampling schemes and acceleration factors, with ROC-AUCs of [~]0.96 and similar Dice scores (up to 0.7). Feature importance analysis indicated that offsets in the range of {+/-}3.0 to 5.0ppm contributed most to the anomaly score. DiscussionThis study successfully demonstrated a UAD pipeline utilizing the Z-spectrum from CEST MRI for metabolically informed tumor delineation. The framework captures biochemical deviations that may precede or extend beyond morphologic abnormalities, enabling sensitive detection of tumor regions and intra-tumoral heterogeneity that previous methods may fail to capture. The offsets from the feature analysis indicated a strong contribution from the magnetization transfer (MT) pool to the spectral deviations captured by the model, with additional contributions from relayed nuclear Overhauser effect (rNOE) and amide proton transfer (APT). Model robustness with under sampling further highlights the pipelines potential in accelerated acquisitions, thus improving clinical practicality. While there is a need for validation on larger cohorts and clinical datasets, the current results demonstrate that this label-free, Z-spectral anomaly mapping can serve as an interpretable and scalable tool for monitoring tumor heterogeneity and progression, with potential applicability to other diffuse or metabolically subtle pathologies.

cancer biology↗

Analysis of 8000 proteins and reduced carry over significantly increase the throughput of single-shot proteomics

In the field of LC-MS based proteomics, increases in sampling depth and proteome coverage have mainly been accomplished by rapid advances in mass spectrometer technology. The comprehensiveness and quality of data that can be generated do however also depend on the performance provided by nano liquid chromatography (nanoLC) separations. Proper selection of reversed-phase separation columns can be important to provide the MS instrument with peptides at the highest possible concentration and separated at the highest possible resolution. In the current contribution, we evaluate the use of prototype generation 2 PAC nanoLC columns which use C18 functionalized superficially porous micro pillars as a stationary phase. When comparing to traditionally used fully porous silica stationary phases, more precursors could be characterized when performing single shot data-dependent LC-MS/MS analyses of a human cell line tryptic digest. Up to 30% more protein groups and 60% more unique peptides were identified for short gradients (10 min) and limited sample amounts (10-100 ng of cell lysate digest). With LC-MS gradient times of 10, 60, 120 and 180 min, we respectively identified 2252, 6513, 7382 and 8174 protein groups with 25, 500, 1000 and 2000 ng of sample loaded on column. Reduction of sample carry over to the next run (up to 2 to 3%) and decreased levels of methionine oxidation (up to 3-fold) were identified as additional figures of merit. When analyzing a disuccinimidyl dibutyric urea (DSBU) crosslinked synthetic library, 29 to 59 more unique crosslinked peptides could be identified at a experimentally validated false discovery rate (FDR) of 1-2%.

biochemistry↗

Assessing biomass and primary production of microphytobenthos in depositional coastal systems using spectral information

In depositional intertidal coastal systems, primary production is dominated by benthic microalgae (microphytobenthos) inhabiting the mudflats. This benthic productivity is supporting secondary production and supplying important services to humans including food provisioning. Increased frequencies of extreme events in weather (such as heatwaves, storm surges and cloudbursts) are expected to strongly impact the spatiotemporal dynamics of the microphytobenthos and subsequently their contribution to coastal food webs. Within north-western Europe, the years 2018 and 2019 were characterized by record-breaking summer temperatures and accompanying droughts. Field-calibrated satellite data (Sentinel 2) were used to quantify the seasonal dynamics of microphytobenthos biomass and production at an unprecedented spatial and temporal resolution during these years. We demonstrate that the Normalized Difference Vegetation Index (NDVI) should be used with caution in depositional coastal intertidal systems, because it may reflect import of remains of allochthonous pelagic productivity rather than local benthic biomass. We show that the reduction in summer biomass of the benthic microalgae cannot be explained by grazing but was most probably due to the high temperatures. The fivefold increase in salinity from January to September 2018, resulting from reduced river run-off during this exceptionally dry year, cannot have been without consequences for the vitality of the microphytobenthos community and its resistance to wind stress and cloud bursts. Comparison to historical information revealed that primary productivity of microphytobenthos may vary at least fivefold due to variations in environmental conditions. Therefore, ongoing changes in environmental conditions and especially extreme events because of climate change will not only lead to changes in spatiotemporal patterns of benthic primary production but also to changes in biodiversity of life under water and ecosystem services including food supply. Satellite MPB data allows for adequate choices in selecting coastal biodiversity conservation and coastal food supply. HIGHLIGHTSO_LIExpected seasonality changes require large-scale and high-resolution coastal data C_LIO_LINDVI of tidal flats reflects local benthic biomass and allochthonous phytoplankton C_LIO_LIHigh summer temperatures reduced biomass and productivity of benthic microalgae C_LIO_LILong-term data revealed a five-fold variation in MPB biomass and production C_LIO_LISatellite MPB data allow for adequate conservation of coastal biodiversity C_LI

ecology↗

Improved Sensitivity in Low-Input Proteomics using Micro-Pillar Array-based Chromatography

Capitalizing on the massive increase in sample concentrations which are produced by extremely low elution volumes, nano-LC-ESI-MS/MS is currently one of the most sensitive analytical technologies for the comprehensive characterization of complex protein samples.\n\nHowever, despite tremendous technological improvements made in the production and the packing of monodisperse spherical particles for nano-flow HPLC, current state-of-the-art systems still suffer from limits in operation at the maximum potential of the technology.\n\nWith the recent introduction of the {micro}PAC system, which provides perfectly ordered micro-pillar array based chromatographic support materials, completely new chromatographic concepts for optimization towards the needs of ultra-sensitive proteomics become available.\n\nHere we report on a series of benchmarking experiments comparing the performance of a commercially available 50 cm micro-pillar array column to a widely used nano-flow HPLC column for the proteomics analysis of 10 ng tryptic HeLa cell digest.\n\nComparative analysis of LC-MS/MS-data corroborated that micro-pillar array cartridges provide outstanding chromatographic performance, excellent retention time stability, increase sensitivity in the analysis of low-input proteomics samples, and thus repeatedly yielded almost twice as many unique peptide and unique protein group identifications when compared to conventional nano-flow HPLC columns.

biochemistry↗

Digging deeper into the human proteome: A novel nanoflow LCMS setup using micro pillar array columns (μPAC™)

In bottom-up proteomics, capillaries up to 75 cm long with internal diameters of 50 to 100 {micro}m packed with sub-2-{micro}m C18-functionalized particles are routinely used in combination with high-resolution mass spectrometry. Unlike such conventional liquid chromatography (LC) columns, micro pillar array columns ({micro}PAC) are fabricated using micromachining technology, resulting in perfectly ordered chromatographic separation beds, leading to a minimized analyte dispersion while column permeability is increased by one order of magnitude. This allows using very long columns (up to 200 cm) at only a fraction of the pressure needed to operate packed bed columns. To validate {micro}PAC column performances, different amounts of tryptic digests of HEK293T cell lysates were prepared and separated using a 200 cm {micro}PAC column or a 40 cm long conventional column. Using an Orbitrap Elite instrument, on average 25% more proteins were identified with the {micro}PAC column. Moreover, the rate at which the peak width increases with gradient time is much lower on the {micro}PAC column. For a 10-hour long gradient, average peak widths below 0.5 min were observed, resulting in consistent identification of over 5,000 proteins. Combining long solvent gradients and this new type of LC column, substantial improvements in proteome coverage could be obtained. Finally, we demonstrated high reproducibility and durability of the {micro}PAC column. Data are available via ProteomeXchange with identifiers PXD011547 and PXD013235.

biochemistry↗