bioRxiv Science⌕ Search

Biology subjects

Hooke, A.

Publications and source records attributed to Hooke, A..

2 recordsLinked to original sources

Mechanical and possible auxetic properties of human Achilles tendon during in vitro testing to failure

The Achilles tendon is the strongest tendon in the human body, but the basis of its high tensile strength has not been elucidated in detail. Here we have loaded healthy, human, Achilles tendons to failure in an anatomically authentic fashion while studying the local three-dimensional deformation and strains in real time, with very high precision, using digital image correlation (DIC). These studies identified a remarkable degree of anisotropic, medio-lateral auxetic behavior, with Poissons ratios not exceeding minus 1 in any part of the tendon at any time; under certain loads, discrete areas within the tendon had a Poissons ratio below minus 6. Early in the loading cycle, the proximal region of the tendon accumulated high lateral strains while longitudinal strains remained low. This behavior shielded the mid-substance of the tendon, its weakest part, from high longitudinal strains until immediately before rupture. These new insights are of great relevance to understanding the material basis of tendon injuries, designing improved prosthetic replacements, and developing regenerative strategies.

bioengineering↗

Calibration and Evaluation of a Force Measurement Glove for Field-Based Monitoring of Manual Wheelchair Users

Manual wheelchair users exhibit pain related to repetitive and demanding shoulder activities of daily living. Wearable sensing systems like force measurement gloves can provide insights about upper extremity loading in the community and home environments. We calibrated and evaluated the accuracy of a novel force measurement glove with a body-worn data logger. The device was calibrated with loads of 0-800 N applied to the palmar surface of the glove. Calibration conditions were tested that varied the stiffness of the material in the glove, the temperature, and the curvature of the force applicator. Calibration equations from each condition were evaluated by comparing the gloves force prediction with the output of an instrumented wheelchair rim during propulsion and weight relief exercises. The force measurement glove detected 72.7% of 355 propulsion peaks and had a strong linear correlation with the instrumented rim force measurements (r=0.80). The most accurate calibration equation was constructed using data from all conditions, with an RMS force measurement error of 64.7 N and 31.7 N for weight relief exercise and propulsion, respectively. The force measurement glove design described here may serve as a useful tool for detection of loading events and relative magnitude changes.

bioengineering↗