A rapid, sensitive, and quantitative high plex biomarker digital detection platform enabled by Hypercoding

Low-cost, multiplexed, and automated assays are needed to make omic technologies more broadly accessible in clinical, research, and commercial settings. We present Hypercoding, a scalable technology for detection and quantitation of multi-omic targets. Drawing from data reliability methods in the telecommunications field, Hypercoding uses fluorescent signals from hybridization with an error-correcting code to enable detection of high-plexity targets from biological samples, such as human DNA. In the presence of the target, a linear DNA construct is circularized, immobilized, and amplified to enable single-molecule detection of a target via rapid readout cycles within a 96-well plate. We demonstrate capability for >10,000 code plexity and accurate (98.7%) genotyping of 209 pharmacogenomic variants. Furthermore, we show computation of copy number variation with whole chromosome and sub-gene resolution, as well as quantitation of target abundance down to 10 fM sensitivity with a dynamic range of up to 10 logs.

genomics↗

High sensitivity cameras can lower spatial resolution in high-resolution optical microscopy

High-resolution optical fluorescence microscopies and, in particular, super-resolution fluorescence microscopy, are rapidly adopting highly sensitive cameras as their referred photodetectors. Camera-based parallel detection facilitates high-speed live cell imaging with the highest spatial resolution. Here, we show that the drive to use ever more sensitive, photon-counting image sensors in cameras can, however, have detrimental effects on spatial resolution that many researchers are not aware of. Typical parameters which influence the selection of image sensors are pixel size, quantum efficiency, signal-to-noise performance, dynamic range, and frame rate of the sensor. A parameter that is, however, often overlooked, is the sensors modulation transfer function (MTF). We have determined the wavelength-specific MTF of front- and back-illuminated image sensors and evaluated how it affects the spatial resolution that can be achieved in high fluorescence microscopy modalities. We find significant differences in image sensor performance for sensors that cause the resulting spatial resolution to vary with up to 28%. This result shows that the choice of image sensor has significant impact on the imaging performance of all camera-based optical microscopy modalities.

biophysics↗