bioRxiv Science⌕ Search

Biology subjects

Hattne, J.

Publications and source records attributed to Hattne, J..

22 records · Page 2Linked to original sources

Analysis of global and site-specific radiation damage in cryo-EM

Micro-crystal electron diffraction (MicroED) is an emerging method in cryo-EM for structure determination using nanocrystals. It has been used to solve structures of a diverse set of biomolecules and materials, in some cases to sub-atomic resolution. However, little is known about the damaging effects of the electron beam on samples during such measurements. We assess global and site-specific damage from electron radiation on nanocrystals of proteinase K and of a prion hepta-peptide and find that the dynamics of electron-induced damage follow well-established trends observed in X-ray crystallography. Metal ions are perturbed, disulfide bonds are broken, and acidic side chains are decarboxylated while the diffracted intensities decay exponentially with increasing exposure. A better understanding of radiation damage in MicroED improves our assessment and processing of all types of cryo-EM data.

biochemistry↗

MicroED Structures of HIV-1 Gag CTD-SP1 Reveal Binding Interactions with the Maturation Inhibitor Bevirimat

HIV-1 protease (PR) cleavage of the Gag polyprotein triggers the assembly of mature, infectious particles. Final cleavage of Gag occurs at the junction helix between the capsid protein CA and the SP1 spacer peptide. Here we used MicroED to delineate the binding interactions of the maturation inhibitor bevirimat (BVM) using very thin frozen-hydrated, three-dimensional microcrystals of a CTD-SP1 Gag construct with and without bound BVM. The 2.9-[A] MicroED structure revealed that a single BVM molecule stabilizes the 6-helix bundle via both electrostatic interactions with the dimethysuccinyl moiety and hydrophobic interactions with the pentacyclic triterpenoid ring. These results provide insight into the mechanism of action of BVM and related maturation inhibitors that will inform further drug discovery efforts. This study also demonstrates the capabilities of MicroED for structure-based drug design.\n\nOne-sentence summaryThe MicroED structure of HIV-1 Gag CTD-SP1 at 2.9 [A] resolution reveals the molecular basis for binding of the maturation inhibitor bevirimat that will inform further drug discovery efforts.

biophysics↗

A method to minimize condenser lens-induced hysteresis effects in a JEOL JEM-3200FSC microscope to enable stable cryoEM low-dose operations

Low dose imaging procedures are key for a successful cryoEM experiment (whether by electron cryotomography, single particle analysis, electron crystallography, or MicroED). We present a method to minimize magnetic hysteresis of the condenser lens system in the JEOL JEM-3200FSC transmission electron microscope (TEM) in order to maintain a stable optical axis for the beam path of low-dose imaging. The simple procedure involves independent voltage ramping of the CL1 and CL2 lenses immediately before switching to the focusing and exposure beam settings for data collection.\n\nHighlights O_LIEnables consistent horizontal beam position during low-dose mode switching\nC_LIO_LIFacilitates EM automated data collection for the JEOL JEM-3200FSC\nC_LIO_LIImproves beam stability in both TEM imaging and diffraction modes\nC_LI

biophysics↗

MicroED Structures from Micrometer Thick Protein Crystals

Theoretical calculations suggest that crystals exceeding 100 nm thickness are excluded by dynamical scattering from successful structure determination using microcrystal electron diffraction (MicroED). These calculations are at odds with experimental results where MicroED structures have been determined from significantly thicker crystals. Here we systematically evaluate the influence of thickness on the accuracy of MicroED intensities and the ability to determine structures from protein crystals one micrometer thick. To do so, we compare ab initio structures of a human prion protein segment determined from thin crystals to those determined from crystals up to one micrometer thick. We also compare molecular replacement solutions from crystals of varying thickness for a larger globular protein, proteinase K. Our results indicate that structures can be reliably determined from crystals at least an order of magnitude thicker than previously suggested by simulation, opening the possibility for an even broader range of MicroED experiments.\n\nSummaryAtomic resolution protein structures can be determined by MicroED from crystals that surpass the theoretical maximum thickness limit by an order of magnitude.

biochemistry↗