bioRxiv Science⌕ Search

Biology subjects

Hassan, A. M.

Publications and source records attributed to Hassan, A. M..

4 recordsLinked to original sources

Ongoing evolution of Middle East Respiratory Syndrome Coronavirus, Kingdom of Saudi Arabia, 2023-2024

Middle East respiratory syndrome coronavirus (MERS-CoV) circulates in dromedary camels in the Arabian Peninsula and occasionally causes spillover infections in humans. Due to lack of sampling during the SARS-CoV-2 pandemic, current MERS-CoV diversity is poorly understood. Of 558 dromedary camel nasal swabs from Saudi Arabia, sampled November 2023 to January 2024, 39% were positive for MERS-CoV RNA by RT-PCR. We generated 42 MERS-CoV and seven human 229E-related CoV by high-throughput sequencing. For both viruses, the sequences fell into monophyletic clades apical to the most recent available genomes. The MERS-CoV sequences were most similar to those from lineage B5. The new MERS-CoVs sequences harbor unique genetic features, including novel amino acid polymorphisms in the Spike protein. The new variants require further phenotypic characterization to understand their impact. Ongoing MERS-CoV spillovers into humans pose significant public health concerns, emphasizing the need for continued surveillance and phenotypic studies.

evolutionary biology↗

An evaluation of resonant scanning as a high-speed imaging technique for two-photon imaging of cortical vasculature

We demonstrate a simple, low-cost two-photon microscope design with both galvo-galvo and resonant-galvo scanning capabilities. We quantify and compare the signal-to-noise ratios and imaging speeds of the galvo-galvo and resonant-galvo scanning modes when used for murine neurovascular imaging. The two scanning modes perform as expected under shot-noise limited detection and are found to achieve comparable signal-to-noise ratios. Resonant-galvo scanning is capable of reaching desired signal-to-noise ratios using less acquisition time when higher excitation power can be used. Given equal excitation power and total pixel dwell time between the two methods, galvo-galvo scanning outperforms resonant-galvo scanning in image quality when detection deviates from being shot-noise limited.

neuroscience↗

Diamond Raman Laser and Yb Fiber Amplifier for In Vivo Multiphoton Fluorescence Microscopy

Here we introduce a fiber amplifier and a diamond Raman laser that output high powers (6.5 W, 1.3 W) at valuable wavelengths (1060 nm, 1250 nm) for multiphoton excitation of red-shifted fluorophores. These custom excitation sources are both simple to construct and cost-efficient in comparison to similar custom and commercial alternatives. Furthermore, they operate at a repetition rate (80 MHz) that allows fast image acquisition using resonant scanners. We demonstrate our systems compatibility with fast resonant scanning, the ability to acquire neuronal images, and the capability to image vasculature at deep locations (>1 mm) within the mouse cerebral cortex.

neuroscience↗

In vivo multiphoton fluorescence imaging with polymer dots

Deep in vivo imaging of vasculature requires small, bright, and photostable fluorophores suitable for multiphoton microscopy (MPM). Although semiconducting polymer dots (pdots) are an emerging class of highly fluorescent contrast agents with favorable advantages for the next generation of in vivo imaging, their use for deep multiphoton imaging has never before been demonstrated. Here we characterize the multiphoton properties of three pdot variants (CNPPV, PFBT, and PFPV) and demonstrate deep imaging of cortical microvasculature in C57 mice. Specifically, we measure the two-versus three-photon power dependence of these pdots and observe a clear three-photon excitation signature at wavelengths longer than 1300 nm, and a transition from two-photon to three-photon excitation within a 1060 - 1300 nm excitation range. Furthermore, we show that pdots enable in vivo two-photon imaging of cerebrovascular architecture in mice up to 850 m beneath the pial surface using 800 nm excitation. In contrast with traditional multiphoton probes, we also demonstrate that the broad multiphoton absorption spectrum of pdots permits imaging at longer wavelengths ({lambda}ex = 1,060 and 1225 nm). These wavelengths approach an ideal biological imaging wavelength near 1,300 nm and confer compatibility with a high-power ytterbium-fiber laser and a high pulse energy optical parametric amplifier, resulting in substantial improvements in signal-to-background ratio (>3.5-fold) and greater cortical imaging depths of 900 m and 1300 m. Ultimately, pdots are a versatile tool for MPM due to their extraordinary brightness and broad absorption, which will undoubtedly unlock the ability to interrogate deep structures in vivo.

bioengineering↗