bioRxiv Science⌕ Search

Biology subjects

Harmening, W. M.

Publications and source records attributed to Harmening, W. M..

8 recordsLinked to original sources

Subfoveal scotomas trigger fine-scale fixation reorganization: insights from retinal imaging and retinal-contingent stimulation

Fine spatial vision relies on the foveola, the 1-degree retinal region with highest cone density. Despite its importance, the relationship between retinal anatomy, fixational behavior, and visual perception in the foveola is not fully understood. Using an Adaptive Optics Scanning Light Ophthalmoscope for high-resolution retinal imaging and stimulation, we studied the effect of a simulated subfoveolar ({approx}0.03 degrees2) scotoma on fine spatial vision and fixation behavior in healthy observers. Our findings show that the visuomotor system adapts to the scotoma with striking precision by shifting the preferred locus of fixation in a systematic fashion by minute ({approx}5 arcmin) amounts to bring stimuli into a region of visibility. These results reveal an unprecedented level of fine-scale plasticity in the human visuomotor system. Interestingly, this new retinal locus of fixation is characterized by lower cone density among those surrounding the scotoma, indicating that factors beyond spatial sampling maximization influence these fine-scale adjustments.

neuroscience↗

Neural contrast sensitivity is not affected by myopic blur

PurposeThe prevalence of myopia is increasing worldwide, accompanied by an increase of potentially under-corrected myopes. Because the neural pathways processing the retinal image are prone to adaptation in relation to the retinal image quality, we wondered to what extent neural contrast sensitivity (NCS) is altered in the presence of myopic blur. Additionally, the impact of retinal abnormalities like foveal hypoplasia with albinism on NCS was tested. MethodsNCS was psychophysically determined for 11 emmetropic, 23 myopic well-corrected and 15 myopic under-corrected otherwise healthy young (27 {+/-} 6 years) participants and 1 albinism patient. Aberration-free stimulation, independent of the eyes refractive state, was achieved by using a unique spatial light modulator-based interferometric system to bypass the eyes optics. ResultsNo significant differences in NCS were observed between the three groups (Median area-under-curve: 61.9, 62.1, and 62.9 for emmetropes, well-corrected, and under-corrected myopes, respectively; all p > 0.1) but were significantly equivalent between emmetropes and myopes (all p < 0.001). However, the NCS function of the albinism patient differed significantly from the here defined "normal" NCS function. ConclusionsNCS is unaffected by myopic blur and remains stable even for under-correction of up to 1.5 D. This means, that long-term under-corrected myopes still can achieve normal visual acuity as soon as their refractive errors are sufficiently corrected. Furthermore, NCS testing can relate visual deficits to an underlying neurological disorder.

neuroscience↗

Sub-cone visual resolution by active, adaptive sampling in the human foveola

The foveated architecture of the human retina and the eyes mobility enable prime spatial vision, yet the interplay between photoreceptor cell topography and the constant motion of the eye during fixation remains unexplored. With in vivo foveal cone-resolved imaging and simultaneous microscopic photo stimulation, we examined visual acuity in both eyes of 16 participants while precisely recording the stimulus path on the retina. We find that resolution thresholds were correlated with the individual retinas sampling capacity, and exceeded what static sampling limits would predict by 18 %, on average. The length and direction of fixational drift motion, previously thought to be primarily random, played a key role in achieving this sub-cone diameter resolution. The oculomotor system finely adjusts drift behavior towards retinal areas with higher cone densities within only a few hundred milliseconds to enhance retinal sampling.

neuroscience↗

Fixational eye movements as active sensation for high visual acuity

Perception and action are inherently entangled: our world view is shaped by how we explore and navigate our environment through complex and variable self-motion. Even when fixating on a stable stimulus, our eyes undergo small, involuntary movements. Fixational eye movements (FEM) render a stable world jittery on our retinae, which contributes noise to neural coding. Yet, empirical evidence suggests that FEM help rather than harm human perception of fine detail. Here, we elucidate this paradox by uncovering under which conditions FEM improve or impair retinal coding and human acuity. We combine theory and experiment: model accuracy is directly compared to that of healthy human subjects in a visual acuity task. Acuity is modeled by applying an ideal Bayesian classifier to simulations of retinal spiking activity in the presence of FEM. In addition, empirical FEM are monitored using high-resolution eye-tracking by an adaptive optics scanning laser ophthalmoscope. While FEM introduce noise, they also effectively pre-process visual inputs to facilitate retinal information encoding. Based on an interplay of these mechanisms, our model predicts a relation between visual acuity, FEM amplitude, and single-trial stimulus size that quantitatively accounts for experimental observations and captures the beneficial effect of FEM. Moreover, we observe that human subjects FEM statistics vary with stimulus size, and our model suggests that changing eye motion amplitude, as the subjects indeed do, enhances acuity as compared to maintaining eye motion size constant. Overall, our findings indicate that perception benefits from action even at the fine and noise-dominated spatio-temporal scale of FEM. Significance StatementPerception is inherently active: we need to move our eyes to see the world around us. Yet our eyes also undergo tiny, unconscious movements that can blur out fine visual details. Paradoxically, previous work suggested that these small movements aid fine detail perception. Here, we investigate this paradox to uncover in which contexts small eye movements help or harm visual acuity. Comparing a model of retinal responses with recordings of human visual acuity, we elucidate the mechanisms by which and conditions in which small eye movements support fine detail discrimination. Our results also suggest that varying eye movement amplitude according to stimulus size enhances retinal coding, highlighting that perception is active even at the level of very fine eye movements.

neuroscience↗

Assessment of binocular fixational eye movements including cyclotorsion with split-field binocular scanning laser ophthalmoscopy

Fixational eye movements are a hallmark of human gaze behavior, yet little is known about how they interact between fellow eyes. Here, we designed, built and validated a split-field binocular scanning laser ophthalmoscope (bSLO) to record high-resolution eye motion traces from both eyes of six observers during fixation at different binocular vergence conditions. In addition to microsaccades and drift, torsional eye motion could be extracted, with a spatial measurement error of less than 1 arcmin. Microsaccades were strongly coupled between fellow eyes under all conditions. No monocular microsaccade occurred and no significant delay between microsaccade onsets across fellow eyes could be detected. Cyclotorsion was also firmly coupled between both eyes, occurring typically in conjugacy, with gradual changes during drift and abrupt changes during saccades.

bioengineering↗

Human gaze is precisely aligned with the foveolar cone topography of both eyes

The small physical depression of the human retina, the fovea, is the retinal locus of prime visual resolution, achieved by a peaking topography of the light sensitive cone photoreceptor outer segments 1-3 and a post-receptor wiring scheme preserving high-density sampling 4,5. Humans dynamically direct their gaze such that the retinal images of objects of interest fall onto the foveola, the central one-degree diameter of the fovea 6-8, but it is yet unclear if a relationship between the individual photoreceptor topography at this location and visual fixation behavior exists 9,10. By employing adaptive optics in vivo imaging and micro-stimulation 11-13, we created topographical maps of the complete foveolar cone mosaics in both eyes of 20 healthy participants while simultaneously recording the retinal location of a fixated visual object in a psychophysical experiment with cellular resolution. We found that the locus of fixation was systematically shifted away from the topographical centers towards a naso-superior quadrant on the retina, about 5 minutes of arc of visual angle on average, with a mirror symmetrical trend between fellow eyes. In cyclopean view, the topographical centers were superior to the fixated target, corresponding to areas in the visual field usually more distant 14,15 and thus containing higher spatial frequencies. Given the large variability in foveal topography between individuals, and the surprising precision with which fixation is repeatedly directed to just a small bouquet of cones in the foveola, these findings demonstrate a finely tuned, functionally relevant link between the development of the cellular mosaic of photoreceptors and visual behavior.

neuroscience↗

Retinal factors of visual sensitivity in the human fovea

Humans direct their gaze towards visual objects of interest such that the retinal images of fixated objects fall onto the fovea, a small anatomically and physiologically specialized region of the retina displaying highest visual fidelity. One striking anatomical feature of the fovea is its non-uniform cellular topography, with a steep decline of cone photoreceptor density and outer segment length with increasing distance from its center. We here assessed in how far the specific cellular organization of the foveola is reflected in visual function. Increment sensitivity to small spot visual stimuli (1 x 1 arcmin, 543 nm light) was recorded psychophysically in 4 human participants at 17 locations placed concentric within a 0.2-degree diameter around the preferred retinal locus of fixation with adaptive optics scanning laser ophthalmoscopy based microstimulation. While cone density as well as maximum outer segment length differed significantly among the four tested participants, the range of observed threshold was similar, yielding an average increment threshold of 3.3 {+/-} 0.2 log10 photons at the cornea. Thresholds were correlated with retinal eccentricity, as well as cone density and outer segment length. Biophysical simulation allowed to develop a model of foveal sensitivity based on these parameters, explaining at least 37% of the observed threshold variability. Based on high reproducibility in replicate testing, the residual variability is assumed to be caused by individual cone and bipolar cell weighting at the specific target locations.

neuroscience↗

Eye tracking-based estimation and compensation of chromatic offsets for multi-wavelength retinal microstimulation with foveal cone precision

Multi-wavelength ophthalmic imaging and stimulation of photoreceptor cells requires consideration of chromatic dispersion of the eye, manifesting in longitudinal and transverse chromatic aberrations. Current image-based techniques to measure and correct transverse chromatic aberration (TCA) and the resulting transverse chromatic offset (TCO) in an adaptive optics retinal imaging system are precise, but lack compensation of small but significant shifts in eye position occurring during in vivo testing. Here we present a method that requires only a single measurement of TCO during controlled movements of the eye to map retinal chromatic image shifts to the image space of a pupil camera. After such calibration, TCO can be compensated by continuously monitoring eye position during experimentation and by interpolating correction vectors from a linear fit to the calibration data. The average change rate of TCO per head shift and the correlation between Kappa and the individual foveal TCA are close to the expectations based on a chromatic eye model. Our solution enables continuous correction of TCO with high spatial precision and avoids high light intensities required for re-measuring TCO after eye position changes, which is necessary for foveal cone-targeted psychophysical experimentation.

biophysics↗