bioRxiv Science⌕ Search

Biology subjects

Hamdan, R.

Publications and source records attributed to Hamdan, R..

4 recordsLinked to original sources

Practical TMS coils with maximum focality and various stimulation depths

Conventional transcranial magnetic stimulation (TMS) coils generate a diffuse and shallow electric field (E-field) in the brain. This results in limited spatial targeting precision (focality). Previously, we developed a methodology for designing theoretical TMS coils to achieve optimal trade-off between the depth and focality of the induced E-field, as well as the energy required by the coil. This paper presents methods for the practical design and implementation of such focal-deep TMS (fdTMS) coils. First, we consider how the coils shape affects energy requirements and design a curved "hat" former that enables a wide range of coil placements while improving energy efficiency compared to flat formers. Second, we introduce a hybrid layer winding implementation to improve energy efficiency by using multi-layer windings in some regions of the coil and a single layer in others. Using simulations with a spherical head model, we benchmark the focality of the fdTMS E-field in the brain and the scalp, as well as the required energy, against conventional TMS coils. We then implement two fdTMS coil designs using copper wire wound inside a 3d-printed plastic former. The E-field of the prototype fdTMS coils and two conventional figure-8 counterparts is measured with a robotic probe to validate the designs. The experimental measurements corroborate the simulations, demonstrating that the fdTMS coils produce a more compact E-field relative to standard figure-8 coils. One potential disadvantage of the fdTMS coil prototypes is wider spread of the scalp E-field and increased energy loss due to the additional windings. Nonetheless, the presented fdTMS coils could offer advantages for precise mapping studies, and the design framework could be leveraged for other coil optimizations.

bioengineering↗

Concurrent fMRI demonstrates propagation of TMS effects across task-related networks

Transcranial magnetic stimulation (TMS) has become an important technique in both scientific and clinical practices, and yet our understanding of how the brain responds to TMS is still limited. Concurrent neuroimaging during TMS may bridge this gap, and emerging evidence suggests widespread that modulatory effects of TMS may be best captured through changes in functional connectivity between distributed networks, rather than local changes in cortical activity. However, the relationship between TMS stimulation parameters and evoked changes in functional connectivity is unknown. In this study, 24 healthy volunteers received concurrent TMS-fMRI while performing a dot-motion direction discrimination task. An MR-compatible coil was used to apply trains of three pulses at 10 Hz rTMS over the primary visual cortex (V1) at the onset of the dot stimuli with four levels of stimulation intensity (20%, 40%, 80%, and 120% of resting motor threshold, RMT). Behavioral results demonstrated impairment of motion discrimination at 80% RMT. FMRI results yielded three findings. First, functional connectivity between visual and non-visual areas increased as a function of rTMS intensity. Second, connectivity within the visual network was positively associated with motion accuracy, while the connectivity between visual and non-visual regions was negatively associated with motion accuracy. Lastly, we found that reductions in the similarity between functional and structural connectivity associated with increasing TMS intensity were constrained to the visual network. These findings demonstrate spatially dependent nonlinear effects of TMS intensity on brain functional connectivity that proceed beyond the site of stimulation and influence associated behavior.

neuroscience↗

Modular multilevel TMS device with wide output range and ultrabrief pulse capability for sound reduction

ObjectiveThis article presents a novel transcranial magnetic stimulation (TMS) pulse generator with a wide range of pulse shape, amplitude, and width. ApproachBased on a modular multilevel TMS (MM-TMS) topology we had proposed previously, we realized the first such device operating at full TMS energy levels. It consists of ten cascaded H-bridge modules, each implemented with insulated-gate bipolar transistors, enabling both novel high-amplitude ultrabrief pulses as well as pulses with conventional amplitude and duration. The MM-TMS device can output pulses including up to 21 voltage levels with a step size of up to 1100 V, allowing relatively flexible generation of various pulse waveforms and sequences. The circuit further allows charging the energy storage capacitor on each of the ten cascaded modules with a conventional TMS power supply. Main resultsThe MM-TMS device can output peak coil voltages and currents of 11 kV and 10 kA, respectively, enabling suprathreshold ultrabrief pulses (> 8.25 s active electric field phase). Further, the MM-TMS device can generate a wide range of near-rectangular monophasic and biphasic pulses, as well as more complex staircase-approximated sinusoidal, polyphasic, and amplitude-modulated pulses. At matched estimated stimulation strength, briefer pulses emit less sound, which could enable quieter TMS. Finally, the MM-TMS device can instantaneously increase or decrease the amplitude from one pulse to the next in discrete steps by adding or removing modules in series, which enables rapid pulse sequences and paired-pulse protocols with variable pulse shapes and amplitudes. SignificanceThe MM-TMS device allows unprecedented control of the pulse characteristics which could enable novel protocols and quieter pulses.

bioengineering↗

Dose-dependent enhancement of motion direction discrimination with transcranial magnetic stimulation of visual cortex

Despite the widespread use of transcranial magnetic stimulation (TMS) in research and clinical care, the underlying mechanisms-of-actions that mediate modulatory effects remain poorly understood. To fill this gap, we studied dose-response functions of TMS for modulation of visual processing. Our approach combined electroencephalography (EEG) with application of single pulse TMS to visual cortex as participants performed a motion perception task. During participants first visit, motion coherence thresholds, 64-channel visual evoked potentials (VEPs), and TMS resting motor thresholds (RMT) were measured. In second and third visits, single pulse TMS was delivered 30 ms before the onset of motion or at the onset latency of the N2 VEP component derived from the first session. TMS was delivered at 0%, 80%, 100%, or 120% of RMT over the site of N2 peak activity, or at 120% over vertex. Behavioral results demonstrated a significant main effect of TMS timing on accuracy, with better performance when TMS was applied at N2-Onset timing versus Pre-Onset, as well as a significant interaction, indicating that 80% intensity produced higher accuracy than other conditions. TMS effects on VEPs showed reduced amplitudes in the 80% Pre-Onset condition, an increase for the 120% N2-Onset condition, and monotonic amplitude scaling with stimulation intensity. The N2 component was not affected by TMS. These findings reveal dose-response relationships between intensity and timing of TMS on visual perception and electrophysiological brain activity, generally indicating greater facilitation at stimulation intensities below RMT.

neuroscience↗