bioRxiv Science⌕ Search

Biology subjects

Guymon, C. A.

Publications and source records attributed to Guymon, C. A..

4 recordsLinked to original sources

The geometry of photopolymerized topography influences neurite pathfinding by directing growth cone morphology and migration

Cochlear implants (CIs) provide auditory perception to those with profound sensorineural hearing loss: however, the quality of sound perceived by a CI user does not approximate natural hearing. This limitation is due in part to the large physical gap between the stimulating electrodes and their target neurons. Therefore, directing the controlled outgrowth of processes from spiral ganglion neurons (SGNs) into close proximity to the electrode array could provide significantly increased hearing function. For this objective to be properly designed and implemented, the ability and limits of SGN neurites to be guided must first be determined. In this work, we engineered precise topographical microfeatures with angle turn challenges of various geometries to study SGN pathfinding. Additionally, we analyze sensory neurite growth in response to topographically patterned substrates and use live imaging to better understand how neurite growth is guided by these cues. In assessing the ability of neurites to sense and turn in response to topographical cues, we find that the geometry of the angled microfeatures determines the ability of neurites to navigate the angled microfeature turns. SGN neurite pathfinding fidelity can be increased by 20-70% through minor increases in microfeature amplitude (depth) and by 25% if the angle of the patterned turn is made more obtuse. Further, by using engineered topographies and live imaging of dorsal root ganglion neurons (DRGNs), we see that DRGN growth cones change their morphology and migration to become more elongated within microfeatures. However, our observations also indicate complexities in studying neurite turning. First, as the growth cone pathfinds in response to the various cues, the associated neurite often reorients across the angle topographical microfeatures. This reorientation is likely related to the tension the neurite shaft experiences when the growth cone elongates in the microfeature around a turn. Additionally, neurite branching is observed in response to topographical guidance cues, most frequently when turning decisions are most uncertain. Overall, the multi-angle channel micropatterned substrate is a versatile and efficient system to assess SGN neurite turning and pathfinding in response to topographical cues. These findings represent fundamental principles of neurite pathfinding that will be essential to consider for the design of 3D systems aiming to guide neurite growth in vivo.

bioengineering↗

Reducing the foreign body response on human cochlear implants and their materials in vivo with photografted zwitterionic hydrogel coatings

The foreign body response to implanted materials often complicates the functionality of sensitive biomedical devices. For cochlear implants, this response can reduce device performance, battery life and preservation of residual acoustic hearing. As a permanent and passive solution to the foreign body response, this work investigates ultra-low-fouling poly(carboxybetaine methacrylate) (pCBMA) thin film hydrogels that are simultaneously photo-grafted and photo-polymerized onto polydimethylsiloxane (PDMS). The cellular anti-fouling properties of these coatings are robustly maintained even after six-months subcutaneous incubation and over a broad range of cross-linker compositions. On pCBMA-coated PDMS sheets implanted subcutaneously, capsule thickness and inflammation are reduced significantly in comparison to uncoated PDMS or coatings of polymerized poly(ethylene glycol dimethacrylate) (pPEGDMA) or poly(hydroxyethyl methacrylate) (pHEMA). Further, capsule thickness is reduced over a wide range of pCBMA cross-linker compositions. On cochlear implant electrode arrays implanted subcutaneously for one year, the coating bridges over the exposed platinum electrodes and dramatically reduces the capsule thickness over the entire implant. Coated cochlear implant electrode arrays could therefore lead to persistent improved performance and reduced risk of residual hearing loss. More generally, the in vivo anti-fibrotic properties of pCBMA coatings also demonstrate potential to mitigate the fibrotic response on a variety of sensing/stimulating implants. Graphical Abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=75 SRC="FIGDIR/small/518125v1_ufig1.gif" ALT="Figure 1"> View larger version (27K): org.highwire.dtl.DTLVardef@1d92121org.highwire.dtl.DTLVardef@e2ca3org.highwire.dtl.DTLVardef@948783org.highwire.dtl.DTLVardef@14ce647_HPS_FORMAT_FIGEXP M_FIG C_FIG

bioengineering↗

Durability of photografted zwitterionic hydrogel coatings for reduction of the foreign body response to cochlear implants

ObjectiveDurability of photografted zwitterionic hydrogel coatings on cochlear implant biomaterials was examined to determine viability of these antifouling surfaces during insertion and long-term implant usage. Approach: Tribometry was used to determine the effect of zwitterionic coatings on lubricity of surfaces with varying hydration level, applied normal force, and timeframe. Additionally, flexural resistance was investigated using mandrel bending. Ex vivo durability was assessed by determining coefficient of friction between tissues and treated surfaces. Furthermore, cochlear implantation force was measured using cadaveric human cochleae. Main results: Hydrated zwitterionic hydrogel coatings reduced frictional resistance approximately 20-fold compared to uncoated PDMS, which importantly led to significantly lower mean force experienced by coated cochlear implants during insertion compared to uncoated systems. Under flexural force, zwitterionic films resisted failure for up to 60 minutes of desiccation. The large increase in lubricity was maintained for 20 hours under continual force while hydrated. For loosely crosslinked systems, films remained stable and lubricious even after rehydration following complete drying. All films remained hydrated and functional under frictional force for at least 30 minutes in ambient conditions while drying, with lower crosslink densities showing the greatest longevity. Moreover, photografted zwitterionic hydrogel samples showed no evidence of degradation and nearly identical lubricity before and after implantation. Significance: This work demonstrates that photografted zwitterionic hydrogel coatings are sufficiently durable to maintain viability before, during, and after implantation. Mechanical properties, including greatly increased lubricity, are preserved after complete drying and rehydration for various applied forces. Additionally, this significantly enhanced lubricity translates to significantly decreased force during insertion of implants which should result in less trauma and scarring.

bioengineering↗

Interaction of micropatterned topographical and biochemical cues to direct neurite growth from spiral ganglion neurons

Functional outcomes with neural prosthetic devices, such as cochlear implants, are limited in part due to physical separation between the stimulating elements and the neurons they stimulate. One strategy to close this gap aims to precisely guide neurite regeneration to position the neurites in closer proximity to electrode arrays. Here, we explore the ability of micropatterned biochemical and topographic guidance cues, singly and in combination, to direct the growth of spiral ganglion neuron (SGN) neurites, the neurons targeted by cochlear implants. Photopolymerization of methacrylate monomers was used to form unidirectional topographical features of ridges and grooves in addition to multidirectional patterns with 90{degrees} angle turns. Microcontact printing was also used to create similar uni- and multi-directional patterns of peptides on polymer surfaces. Biochemical cues included peptides that facilitate (laminin, LN) or repel (EphA4-Fc) neurite growth. On flat surfaces, SGN neurites preferentially grew on LN-coated stripes and avoided EphA4-Fc-coated stripes. LN or EphA4-Fc was selectively adsorbed onto the ridges or grooves to test the neurite response to a combination of topographical and biochemical cues. Coating the ridges with EphA4-Fc and grooves with LN lead to enhanced SGN alignment to topographical patterns. Conversely, EphA4-Fc coating on the grooves or LN coating on the ridges tended to disrupt alignment to topographical patterns. SGN neurites respond to combinations of topographical and biochemical cues and surface patterning that leverages both cues enhance guided neurite growth.

bioengineering↗