bioRxiv Science⌕ Search

Biology subjects

Guillen, A.

Publications and source records attributed to Guillen, A..

5 recordsLinked to original sources

Assessing suitability of ultra-low-field MRI for TES electric field models

ObjectiveRecent ultra-low-field (ULF) MRI systems provide an option for more accessible and cost-effective imaging to widely used higher field (HF, usually 3T) systems. However, it remains uncertain whether ULF scans can be used for reliable TES current-flow modeling as opposed to using 3T MRI. MethodsWe used raw anatomical scans of 23 healthy adults from 64 mT and 3T systems. We enhanced the 64 mT scans using SynthSR. Using our established current-flow modeling pipeline we determined the electric fields (EF) for the ULF and 3T scans induced by the classic M1-SO electrode montage. We quantified the differences in EF at three regions of interest (ROI): left motor cortex (LMC), anterior commissure (AC), and left hippocampus (LHC). ResultsAt the cortical ROI (LMC), the individual mean EF based on a 3T scan was found to be 27% higher than the corresponding ULF scan. The average mean relative error was found to be 40%. At AC, the individual mean EF based on a 3T scan continued to be elevated by about 13% in magnitude with respect to the corresponding ULF scan with a mean error range of 31-34%. At LHC, comparison of the induced individual mean EF magnitudes indicated no clear bias between 3T-based and ULF-based models. The average mean relative error at this level dropped to [~]20%. DiscussionThe substantial decrease in cortical EF when using an ULF scan is predominantly explained by the overestimation of cerebrospinal fluid (CSF) noted by prior morphological comparison studies. Scaling up EF magnitude to match predicted cortical values to a 3T scan may be considered depending on the modeling question being addressed. While preliminary, our results suggest an "equalizing" effect between ULF and 3T predictions with increasing depth within the brain.

bioengineering↗

On the need of individually optimizing temporal interference stimulation of human brains due to inter-individual variability

IntroductionTranscranial temporal interference stimulation (TI, TIS, or tTIS), also known as interferential stimulation (IFS), is able to focally stimulate deep brain regions, provided it is properly optimized. We previously presented an algorithm for optimizing TI using two arrays of electrodes and showed that it can achieve more focal stimulation compared to optimized high-definition transcranial electrical stimulation (HD-TES) and conventional optimized TI using two pairs of electrodes, especially in the deep brain areas such as the hippocampus. However, those modeling studies were only performed on an averaged head (MNI152 template) and three individual heads without exploring inter-individual variability. Existing TI works in the literature mostly utilize a common (possibly optimized) montage of two pairs of electrodes on different individual heads without considering inter-individual variability. Material and methodHere we aim to study the inter-individual variability of optimized TI by applying the same optimization algorithms on N = 25 heads using their individualized head models. Specifically, we compared the focality achieved by different stimulation techniques at six different regions of interest (ROI; right hippocampus, left dorsolateral prefrontal cortex, left motor cortex, right amygdala, right caudate, and left thalamus) under both individually optimized and unoptimized montages. We also conducted numerical sensitivity analysis on the individual optimization and performed phantom recordings to test our models. ResultsAs expected, there is a variability in focality achieved by TI of up to 1.2 cm at the same ROI across subjects due to inter-individual differences in the head anatomy and tissue conductivity. We show that optimized TI using two arrays of electrodes achieves higher focality than that from optimized HD-TES at the same level of modulation intensity at 5 of the 6 ROIs. Compared to using a common montage either optimized from the MNI152 template or from the literature, individually optimized TI using two pairs of electrodes improves the focality by up to 4.4 cm, and by up to 1.1 cm if using two arrays of electrodes. Focality achieved by the individual optimization is sensitive to random changes and can vary up to 9.3 cm due to the non-lienarity of TI physics. Experimental recordings on a head phantom confirms the drop in TI stimulation strength when using unoptimized montages as predicted by our in silico models. ConclusionThis work demonstrates the need of individually optimizing TI to target deep brain areas, and advocates against using a common head model and montage for TI modeling and experimental studies.

biophysics↗

Survival time and prognostic factors in dogs diagnosed with haemangiosarcoma in UK first opinion practice

AbstractVisceral haemangiosarcoma is considered clinically aggressive in dogs, with perceived poor prognosis often leading to euthanasia at presentation. This study aimed to determine survival times and prognostic factors in dogs with haemangiosarcoma under first-opinion care. Dogs diagnosed with haemangiosarcoma in first-opinion practice in 2019 were identified in VetCompass electronic health records (EHRs) and manually examined to capture variables potentially associated with survival. Median survival time (MST) from diagnosis was calculated for the whole population and based on the primary tumour location. Binary logistic regression was used to explore differences between dogs that died on the day of diagnosis and those that survived [≥]1 day. Cox proportional hazards modelling explored factors associated with time to death in dogs that survived [≥]1 day. Across all haemangiosarcoma cases (n=788), overall MST was 9.0 days (95%CI:5.0-15.0, range: 0-1789) and proportional 1-year survival was 12.0% (95%CI:9.7-15.0%). Dogs with splenic (MST=4.0 days, 95%CI 0.0-9.0) and cutaneous haemangiosarcoma (MST=119.0 days,95%CI:85.0-248.0) had MST greater than 0 days. Male sex and increasing tumour size were associated with increased hazard of death while cutaneous location and surgery were associated with reduced hazard of death. A very short survival time was identified for haemangiosarcoma under first-opinion care. Although survival time was longest for cutaneous cases, the actualised prognosis was poor overall for haemangiosarcoma. This study provides valuable information for contextualised care and dialogues with clients in first-opinion practice.

pathology↗

Impact of galvanic vestibular stimulation electrode current density on brain current flow patterns: Does electrode size matter?

BackgroundGalvanic vestibular stimulation (GVS) uses at least one electrode placed on the mastoid process with one or multiple placed over other head areas to stimulate the vestibular system. The exact electrode size used is not given much importance in the literature and has not been reported in several studies. In a previous study, we compared the clinical effects of using different electrode sizes (3 cm2 and 35 cm2) with placebo but with the same injected current, on postural control. We observed significant improvement using the smaller size electrode but not with the bigger size electrode. The goal of this study was to simulate the current flow patterns with the intent to shed light and potentially explain the experimental outcome. MethodsWe used an ultra-high-resolution structural dataset and developed a model to simulate the application of different electrode sizes. We considered current flow in the brain and in the vestibular labyrinth. ResultsOur simulation results verified the focality increase using smaller electrodes that we postulated as the main reason for our clinical effect. The use of smaller size electrodes in combination with the montage employed also result in higher induced electric field (E-field) in the brain. ConclusionsElectrode size and related current density is a critical parameter to characterize any GVS administration as the choice impacts the induced E-field. It is evident that the higher induced E-field likely contributed to the clinical outcome reported in our prior study.

bioengineering↗

Taxonomic composition, community structure and molecular novelty of microeukaryotes in a temperate oligomesotrophic lake as revealed by metabarcoding

Microbial eukaryotes are diverse and ecologically important organisms, yet sampling constraints have hindered the understanding of their distribution and diversity in freshwater ecosystems. Metabarcoding has provided a powerful complement to traditional limnological studies, revealing an unprecedented diversity of protists in freshwater environments. Here, we aim to expand our knowledge of the ecology and diversity of protists in lacustrine ecosystems by targeting the V4 hypervariable region of the 18S rRNA gene in water column, sediment and biofilm samples collected from Sanabria Lake (Spain) and surrounding freshwater ecosystems. Sanabria is a temperate lake, which are relatively understudied by metabarcoding in comparison to alpine and polar lakes. The phylogenetic diversity of microbial eukaryotes detected in Sanabria span all currently recognized eukaryotic supergroups, with Stramenopiles being the most abundant and diverse supergroup in all sampling sites. Parasitic microeukaryotes account for 21% of the total protist ASVs identified in our study and were dominated by Chytridiomycota, both in terms of richness and abundance in all sampling sites. Sediments, biofilms and water column samples harbour distinct microbial communities. Phylogenetic placement of poorly assigned and abundant ASVs indicates molecular novelty inside Rhodophyta, Bigyra, early-branching Nucletmycea and Apusomonadida. In addition, we report the first freshwater incidence of the previously exclusively marine genera Abeoforma and Sphaeroforma. Our results contribute to a deeper understanding of microeukaryotic communities in freshwater ecosystems, and provide the first molecular reference for future biomonitoring surveys in Sanabria Lake.

ecology↗