bioRxiv Science⌕ Search

Biology subjects

Guerrero-Hurtado, M.

Publications and source records attributed to Guerrero-Hurtado, M..

8 recordsLinked to original sources

Joint Vector Flow Mapping and Segmentation: Ill-Posedness,Differentiable Bayesian Inference, and Synthetic Vortex-FlowBenchmarks

Vector flow mapping (VFM) reconstructs left-ventricular (LV) blood velocity from color-Doppler echocardiography by combining the measured beamwise component with physical and regularizing constraints. Analysis of the discrete VFM formulation shows that the inverse problem is intrinsically ill posed: the occurrence of singular modes can be predicted from the geometry of the segmented blood-pool domain, the imposed boundary conditions, and the degree of smoothing. These modes can propagate uncertainty along entire transverse bands of the reconstructed velocity field, yet conventional VFM neither quantifies this uncertainty nor allows for correcting the blood-pool segmentation. We introduce Bayesian VFM (B--VFM), a hierarchical framework that jointly infers radial and transverse velocities, a probabilistic blood-pool mask, their spatially resolved uncertainties, and hyperparameters weighting Doppler and segmentation fidelity, mass conservation, boundary conditions, and smoothness. The discretized posterior admits a closed-form gradient and exact Hessian, enabling computationally efficient, gradient-based MAP estimation, sampling, and direct analysis of ill-posed modes. Posterior inference combines Gibbs sampling of conjugate Gamma-distributed hyperparameters with conditional maximum-a-posteriori estimation and a Laplace approximation for the high-dimensional velocity and mask fields. To accommodate systematic departures from planar mass conservation, B-VFM can learn the covariance of the planar divergence residual from an ensemble of flows and incorporate it as a structured model-discrepancy prior. Independent chains converged reproducibly, while covariance priors learned from flow ensembles illustrated how model discrepancies can be incorporated into the inference. B--VFM was evaluated using Lamb-Chaplygin dipoles under ideal conditions and with Doppler corruption, Doppler voids, and segmentation defects, and using the Hicks-Moffatt family of spherical vortices to assess violations of planar mass conservation. The method produced smooth reconstructions, localized uncertainty near unreliable measurements and regions of model inconsistency, and used flow information to correct segmentation errors. Within the tested vortex family, the data-informed planar divergence prior reduced velocity bias and mask distortion. B--VFM thus provides an uncertainty-aware reconstruction method and a flexible foundation for future VFM formulations incorporating additional priors, observations, and physical models. Future work will evaluate the method using clinical data and more complex three-dimensional benchmark flows.

bioengineering↗

Fibrosis burden and spatial pattern affect left atrial appendage stasis in multi-beat multi-physics simulations

Purpose: Atrial fibrosis is associated with thromboembolic risk in atrial fibrillation, but how fibrosis-related contractile impairment alters blood transport in the left atrium (LA) and left atrial appendage (LAA) remains unclear. Prior multi-physics simulations coupled electromechanical (EM) and computational fluid dynamics (CFD) models to show that fibrosis impairs LA function and flow, but were limited to booster-only contraction and could not separate the effects of fibrosis burden from its spatial distribution. Here we examined how fibrosis burden and spatial pattern independently relate to long-term LA and LAA hemodynamics in full-cycle, multi-beat simulations on a common LA anatomy. Methods: Three fibrosis patterns derived from late gadolinium enhancement MRI were considered: one from the patient providing the common anatomy and two from additional patients, with the latter mapped onto the common anatomy via universal atrial coordinates. All three patterns were applied globally at matched burdens of 15.6% and 31.2%, yielding six global-fibrosis cases and a non-fibrotic reference. Two patterns were also confined to the LAA at three local burdens (10%, 25%, and 50%), yielding six LAA-fibrosis cases. A 3D EM model for the LA anatomy was coupled to a 0D circulatory model, so that the simulations resolved the reservoir, conduit, and booster phases. Full-cycle EM-derived wall motion drove subsequent multi-beat CFD simulations. Region-specific emptying fraction (EF), non-dimensional kinetic energy (KE), and the 90th percentile of blood residence time (TR) were evaluated for the LA and LAA. Results: Left ventricular stroke volume remained nearly constant across cases, while increasing global fibrosis burden progressively reduced LA and LAA EF (LA: 36% to 30-31%; LAA: 44% to 28-38%) and monotonically increased LA TR across all patterns. Non-dimensional LA KE showed an approximately quadratic association with LA EF across patterns, whereas LAA KE was more scattered but still increased with LAA EF. In contrast, the relationship between the 90th percentile of LAA TR and LAA EF showed pattern-specific, non-monotonic trends. Conclusions: Fibrosis burden and spatial distribution jointly shape LA and LAA hemodynamics, but through different mechanisms. LAA EF is a robust functional descriptor of chamber-averaged kinetic energy regardless of fibrosis pattern, whereas LAA blood stasis depends additionally on the spatial distribution of fibrosis beyond what bulk emptying fraction predicts. These findings support incorporating imaging-derived fibrosis pattern, and not only burden, alongside functional metrics when assessing thrombogenic risk in the LAA.

bioengineering↗

Left atrial flow and thrombosis risk from 4D CT contrast dynamics by physics-informed neural network and indicator dilution theory

Atrial fibrillation (AF) promotes blood stasis and thrombus formation, most often within the left atrial appendage (LAA), and can lead to stroke or transient ischemic attack (TIA). Time-resolved contrast-enhanced computed tomography (4D CT) captures left atrial (LA) opacification and washout, but it does not directly provide quantitative stasis metrics such as blood residence time. Patient-specific computational fluid dynamics (CFD) can quantify LA/LAA residence time, yet routine clinical use is limited by computational cost and sensitivity to patient-specific boundary conditions. Here, we present two complementary approaches to infer time-resolved 3D residence time fields directly from contrast dynamics. First, a physics-informed neural network (PINN) treats contrast as a passive scalar and jointly reconstructs velocity and residence time by enforcing the incompressible Navier-Stokes equations and transport equations for contrast concentration and residence time in moving, patient-specific LA anatomies. Second, an indicator dilution theory (IDT) formulation computes voxelwise, time-resolved residence time maps from contrast time curves alone by constructing a PV-referenced impulse response and modeling transport with a tank-in-series model with spatially dependent parameters. Both methods are benchmarked against patient-specific CFD in six cases spanning diverse LA function, including three patients with TIA or thrombus in the LAA and three patients free of events. Both approaches reproduce expected spatial and temporal trends, with higher residence time in the distal LAA and higher LAA residence time in cases with TIA or thrombus. IDT demonstrates the closest agreement with CFD across the full range of residence times and produces maps in seconds, facilitating clinical translation. In contrast, the PINN additionally recovers phase-dependent atrial flow structures, but tends to smooth and underestimate the highest residence-time regions and requires hours of training. Together, these results support a scalable workflow in which IDT enables rapid stasis screening from contrast CT, and PINNs provide a complementary pathway for detailed, patient-specific hemodynamic inference when full-field flow information is needed.

bioengineering↗

Effect of Wall Motion Sampling on CFD-Derived Left Atrial Flow Metrics

The temporal resolution of medical imaging sequences used to drive patient-specific computational fluid dynamics (CFD) simulations remains limited, typically providing 10-20 frames per cardiac cycle. Therefore, temporal interpolation to reconstruct left atrial (LA) wall motion and boundary conditions is required, but its impact on hemodynamic predictions has not been systematically characterized. To investigate this, we constructed high-temporal-resolution reference wall-motion data using electromechanical (EM) simulations on five patient-specific atrial geometries with a history of atrial fibrillation. We then generated temporally downsampled datasets to emulate clinical frame rates (5, 10, 20, and 40 frames per cycle) and performed CFD simulations to isolate the effects of temporal undersampling on hemodynamic metrics. The focus was placed on kinetic energy, KE, and residence time, TR, particularly in the left atrial appendage (LAA), where thrombosis is most likely to occur. We employed an immersed boundary method to prescribe the wall motion and computed blood TR through a passive scalar transport equation. Results indicate that while global LA hemodynamic indices were marginally affected by the frame rate (errors < 9%), LAA metrics were more sensitive with errors up to 31% compared to reference values. The results based on 20 and 40 frames per cycle yielded favorable agreement with reference results, while 5-and 10-frame reconstructions showed larger, though not systematically biased, deviations from the reference. Importantly, patient ranking by blood-stasis indices was largely preserved. The analysis suggests that patientspecific LA reconstructions derived from dynamic CT imaging provide a reliable basis for estimating LAA blood-stasis indices. Higher frame rates ([&ge;] 20 per cycle) offer improved quantitative accuracy, while lower temporal resolutions may remain informative for patient stratification purposes, where relative ranking is more relevant than absolute accuracy.

bioengineering↗

Hemodynamics Affects Factor XI/XII Anticoagulation Efficacy in Patient-Specific Left Atrial Models

Atrial fibrillation (AF) disrupts the circulation of blood through the left atrium (LA), and may result in relative stasis in the left atrial appendage (LAA), increasing thromboembolic risk. Anticoagulant agents can lower this risk, but currently used agents target the common pathway central to the coagulation cascade, increasing bleeding risk. Anticoagulants such as factor XI/XII inhibitors target the initial phase of the intrinsic pathway, with a significantly lower associated bleeding risk. However, these agents efficacy in preventing thrombosis in patient-specific flow conditions is not fully understood. We hypothesized that patient-specific flow patterns in the LA and LAA not only influence the risk of thrombosis but also the effectiveness of anticoagulation agents. We simulated blood flow and the intrinsic coagulation pathway in patient-specific LA anatomies with and without factor XI/XII inhibition to test this hypothesis. We considered thirteen patients in sinus rhythm and AF, several of whom had an LAA clot or a history of transient ischemic attacks. We used computational fluid dynamics based on 4D CT imaging and a detailed 32-species coagulation system to run 247 simulations for 13 patients, systematically sweeping over a wide range of factor XI/XII inhibition levels. Implementing a novel multi-fidelity coagulation modeling approach accelerated computations by two orders of magnitude, enabling the large number of simulations performed. Our simulations provide spatiotemporally resolved maps of thrombin concentration throughout the LA, showing it peaks inside the LAA. Coagulation metrics based on peak LAA thrombin dynamics suggested patients could be classified as non-coagulating, moderately and severely coagulating cases. Severely coagulating cases had significantly slower flow and higher residence time than moderately coagulating patients inside the LAA, requiring stronger factor XI/XII inhibition to blunt thrombin growth. The methodology outlined in this study has the potential to enable personalized assessments of coagulation risk and tailor anticoagulation therapy based on medical imaging.

bioengineering↗

Patient-specific multi-physics simulations of fibrotic changes in left atrial tissue mechanics impact on hemodynamics

Stroke is a leading cause of death and disability worldwide. Atrial myopathy, including fibrosis, is associated with an increased risk of ischemic stroke, but the mechanisms underlying this association are poorly understood. Fibrosis modifies myocardial structure, impairing electrical propagation and tissue biomechanics, and creating stagnant flow regions where clots could form. Fibrosis can be mapped non-invasively using late gadolinium enhancement magnetic resonance imaging (LGE-MRI). However, fibrosis maps are not currently incorporated into stroke risk calculations or computational electro-mechano-fluidic models. We present multi-physics simulations of left atrial (LA) myocardial motion and hemodynamics using patient-specific anatomies and fibrotic maps from LGE-MRI. We modify tissue stiffness and active tension generation in fibrotic regions and investigate how these changes affect LA flow for different fibrotic burdens. We find that fibrotic regions and, to a lesser extent, non-fibrotic regions experience reduced myocardial strain, resulting in decreased LA emptying fraction consistent with clinical observations. Both fibrotic tissue stiffening and hypocontractility independently reduce LA function, but together, these two alterations cause more pronounced effects than either one alone. Fibrosis significantly alters flow patterns throughout the atrial chamber, and particularly, the filling and emptying jets of the left atrial appendage (LAA). The effects of fibrosis in LA flow are largely captured by the concomitant changes in LA emptying fraction except inside the LAA, where a multi-factorial behavior is observed. This work illustrates how high-fidelity, multi-physics models can be used to study thrombogenesis mechanisms in patient-specific anatomies, shedding light onto the links between atrial fibrosis and ischemic stroke. Key pointsO_LILeft atrial (LA) fibrosis is associated with arrhythmogenesis and increased risk of ischemic stroke; its extent and pattern can be quantified on a patient-specific basis using late gadolinium enhancement magnetic resonance imaging. C_LIO_LICurrent stroke risk prediction tools have limited personalization, and their accuracy could be improved by incorporating patient-specific information like fibrotic maps and hemodynamic patterns. C_LIO_LIWe present the first electro-mechano-fluidic multi-physics computational simulations of LA flow, including fibrosis and anatomies from medical imaging. C_LIO_LIMechanical changes in fibrotic tissue impair global LA motion, decreasing LA and left atrial appendage (LAA) emptying fractions, especially in subjects with higher fibrosis burdens. C_LIO_LIFibrotic-mediated LA motion impairment alters LA and LAA flow near the endocardium and the whole cavity, ultimately leading to more stagnant blood regions in the LAA. C_LI

bioengineering↗

Super-resolution Left Ventricular Flow and Pressure Mapping by Navier-Stokes-Informed Neural Networks

Intraventricular vector flow mapping (VFM) is a growingly adopted echocardiographic modality that derives time-resolved two-dimensional flow maps in the left ventricle (LV) from color-Doppler sequences. Current VFM models rely on kinematic constraints arising from planar flow incompressibility. However, these models are not informed by crucial information about flow physics; most notably the pressure and shear forces within the fluid and the resulting accelerations. This limitation has rendered VFM unable to combine information from different time frames in an acquisition sequence or derive fluctuating pressure maps. In this study, we leveraged recent advances in artificial intelligence (AI) to develop AI-VFM, a vector flow mapping modality that uses physics-informed neural networks (PINNs) encoding mass conservation and momentum balance inside the LV, and no-slip boundary conditions at the LV endocardium. AI-VFM recovers the flow and pressure fields in the LV from standard echocardiographic scans. It performs phase unwrapping and recovers flow data in areas without input color-Doppler data. AI-VFM also recovers complete flow maps at time points without color-Doppler input data, producing super-resolution flow maps. We show that informing the PINNs with momentum balance is essential to achieving temporal super-resolution and significantly increases the accuracy of AI-VFM compared to informing the PINNs only with mass conservation. AI-VFM is solely informed by each patients flow physics; it does not utilize explicit smoothness constraints or incorporate data from other patients or flow models. AI-VFM takes 15 minutes to run in off-the-shelf graphics processing units and its underlying PINN framework could be extended to map other flow-associated metrics like blood residence time or the concentration of coagulation species.

bioengineering↗

Efficient multi-fidelity computation of blood coagulation under flow

Clot formation is a crucial process that prevents bleeding, but can lead to severe disorders when imbalanced. This process is regulated by the coagulation cascade, a biochemical network that controls the enzyme thrombin, which converts soluble fibrinogen into the fibrin fibers that constitute clots. Coagulation cascade models are typically complex and involve dozens of partial differential equations (PDEs) representing various chemical species transport, reaction kinetics, and diffusion. Solving these PDE systems computationally is challenging, due to their large size and multi-scale nature. We propose a multi-fidelity strategy to increase the efficiency of coagulation cascade simulations. Leveraging the slower dynamics of molecular diffusion, we transform the governing PDEs into ordinary differential equations (ODEs) representing the evolution of species concentrations versus blood residence time. We then Taylor-expand the ODE solution around the zero-diffusivity limit to obtain spatiotemporal maps of species concentrations in terms of the statistical moments of residence time, [Formula], and provide the governing PDEs for [Formula]. This strategy replaces a high-fidelity system of N PDEs representing the coagulation cascade of N chemical species by N ODEs and p PDEs governing the residence time statistical moments. The multi-fidelity order(p) allows balancing accuracy and computational cost, providing a speedup of over N/p compared to high-fidelity models. Using a simplified coagulation network and an idealized aneurysm geometry with a pulsatile flow as a benchmark, we demonstrate favorable accuracy for low-order models of p = 1 and p = 2. These models depart from the high-fidelity solution by under 16% (p = 1) and 5% (p = 2) after 20 cardiac cycles. The favorable accuracy and low computational cost of multi-fidelity models could enable unprecedented coagulation analyses in complex flow scenarios and extensive reaction networks. Furthermore, it can be generalized to advance our understanding of other systems biology networks affected by blood flow.

bioengineering↗