bioRxiv Science⌕ Search

Biology subjects

Guajardo, D.

Publications and source records attributed to Guajardo, D..

2 recordsLinked to original sources

Effect of Clover versus Zipping on Annular Geometry and Dynamics in Tricuspid Edge-to-Edge Repair

Introduction: Transcatheter edge-to-edge repair effectively reduces tricuspid regurgitation (TR), with some patients showing an additional 'annuloplasty effect'. Methods: Ten adult sheep underwent pulmonary artery banding to induce right ventricular failure and functional TR. Six weeks later, sonomicrometry crystals were implanted around the tricuspid annulus (TA). Two Abbott XTW clips were then placed using either a Zipping (n=5) or Clover (n=5) configuration. Echocardiographic and sonomicrometry data were collected before and after clip implantation to assess TA geometry and function. Results: The model produced right ventricular dilation, dysfunction, and moderate-to-severe functional TR. In all animals, leaflet approximation with two clips significantly reduced TR severity (3.6+/-0.5 to 1.3+/-1.1; p=0.01) and septal-lateral annular diameter (29.2+/-2.2 to 26.7+/-2.9 mm; p=0.01). However, a significant reduction in septal-lateral annular diameter occurred only with the Clover technique (30+/-2 to 27+/-1 mm; p=0.001). Conclusions: Both techniques reduced TR, but only the Clover configuration produced an acute annuloplasty effect by selectively decreasing septal-lateral annular diameter.

bioengineering↗

Transcatheter Edge-to-Edge Repair Increases Annular Forces in In Vitro Whole Heart Preparations

BackgroundTricuspid transcatheter edge-to-edge repair (TEER) can induce an acute annuloplasty effect. While this has a therapeutic benefit, the mechanisms driving the reduction in annular size remain unclear. ObjectivesWe quantify the annular force induced by TEER in vitro in whole porcine heart preparations. We explore the impact of clipping different leaflet pairs on the TEER-induced annular forces. MethodsWe performed 49 interventions in 13 porcine hearts using a MitraClip XT. The clip was implanted between either the anterior-septal (AS), anterior-posterior (AP), or posterior-septal (SP) leaflet pairs. We also considered two-clip interventions between the combination of the AS-AP, AS-PS, or AP-PS leaflet pairs. For each intervention, we measured the right ventricular pressure, transvalvular flow rate, and force at eight locations around the annulus. ResultsTEER induced significant inward-pulling forces on the annulus. The maximum force was induced following an AS-PS two-clip intervention. A single AS clip induced the largest force among the one-clip interventions. Furthermore, the AP and AS-AP interventions induced the smallest annular forces. ConclusionsThe magnitude of the TEER-induced force depends on the intervention and number of clips implanted.

bioengineering↗