bioRxiv Science⌕ Search

Biology subjects

Gizeli, E.

Publications and source records attributed to Gizeli, E..

6 recordsLinked to original sources

Mechanistic Insights into Magnesium Pyrophosphate Formation in the Presence of Gold Nanoclusters Enable Genetic Analysis via Co-Aggregation-Induced Fluorescence Enhancement

The formation of magnesium pyrophosphate (Mg2P2O7) in nucleic acid amplification and cell-free transcription systems has attracted considerable attention, since Mg2P2O7 serves as a reliable indicator of reaction efficiency. However, real-time monitoring of Mg2P2O7 remains challenging, relying largely on time-consuming analytical techniques or end-point detection methods. Here, we report a Mg2P2O7-driven co-aggregation mechanism involving glutathione-capped gold nanoclusters (GSH-AuNCs) that induces fluorescence enhancement, enabling real-time crystal formation monitoring. The mechanism was first investigated in simplified mixtures containing pyrophosphate (P2O74-) and magnesium (Mg2+) ions. Real-time fluorescence profiles revealed that the GSH-AuNCs/Mg2P2O7 co-aggregation can be correlated with crystal formation/growth/solubilization and solution turbidity, while distinct kinetic patterns can be indicative of the crystal size at the end of the reaction. As a next level of complexity, we examined the effects of common components in an enzymatic amplification reaction, i.e., dithiothreitol (DTT), ammonium sulfate ((NH4)2SO4), deoxynucleotides (dNTPs) and Bst polymerase, on Mg2P2O7 formation through real-time GSH-AuNCs fluorescence variations. Guided by the above results, we studied and selected the experimental parameters for the design of an optimized qualitative (end-point) or quantitative (real-time) genetic test. Finally, the loop-mediated isothermal amplification (LAMP) was used as a platform to demonstrate the quantification of Influenza A RNA within the range of 102-108 copies/reaction. The resulting one-tube, contamination-free assay was shown to have a response time of <25 min even in a crude saliva sample. Beyond diagnostics, this crystallization-activated fluorescence strategy may also support real-time investigation of Mg2P2O7 formation in other biotechnological processes, including in vitro transcription and Mg2P2O7-bioorganic composites synthesis. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=80 SRC="FIGDIR/small/744482v1_ufig1.gif" ALT="Figure 1"> View larger version (37K): org.highwire.dtl.DTLVardef@42206dorg.highwire.dtl.DTLVardef@15edc71org.highwire.dtl.DTLVardef@dab2b5org.highwire.dtl.DTLVardef@aa535_HPS_FORMAT_FIGEXP M_FIG C_FIG

molecular biology↗

Universal rapid RNA-based quantification of toxigenic Alexandrium species (Dinophyceae) using quantitative recombinase polymerase amplification

Harmful algal blooms caused by toxigenic Alexandrium species pose recurrent risks to coastal ecosystems and public health, yet current monitoring approaches rely on microscopy and laboratory-based toxin analysis with limited capacity for rapid, functional early warning. Here, we present a universal quantitative reverse-transcriptase recombinase polymerase amplification (qRT-RPA) assay targeting the sxtA4 transcript, an essential gene in saxitoxin biosynthesis. The RPA chemistry is isothermal with a low running temperature, making it suitable for portable, on-site testing. The assay was designed against a conserved sxtA4 region and validated using isolated sxtA4 amplicons from multiple Alexandrium species, synthetic DNA and RNA templates, and total RNA of Alexandrium minutum as a widespread reference species. The assay achieved uniform amplification kinetics across species, a limit of detection below 103 synthetic RNA copies and 0.1 ng total RNA per reaction for A. minutum, and a runtime of less than 15 minutes. The assay selectively detected sxtA4 transcripts from toxigenic Alexandrium strains and showed no cross-reactivity with non-target phytoplankton. A limit of detection that is relevant to early warning for Alexandrium species (under 20 cells per reaction) was retained in complex RNA matrices. Mock samples prepared by spiking cultured cells into natural seawater also demonstrated detection at field-relevant concentrations. These results establish qRT-RPA as a rapid, RNA-based, functionally informative molecular tool that provides a foundation for portable, early-warning monitoring of potentially toxigenic Alexandrium blooms.

microbiology↗

Development of a quantitative colorimetric LAMP assay for fast and targeted molecular detection of the invasive lionfish Pterois miles from environmental DNA

The Mediterranean basin has seen an increased influx of invasive species since the Suez Canal expansion in 2015. The invasive lionfish species, Pterois miles, has rapidly established new populations in the Eastern Mediterranean Sea, impacting local fish biodiversity. Here, we have developed a new, fast (< 35 min) molecular approach to detect and quantify P. miles environmental DNA (eDNA) in combination with a portable device for field-based analysis. Using a species-specific real-time colorimetric loop-mediated isothermal amplification (qcLAMP) for the cytochrome oxidase subunit 1 (COI) gene, we demonstrate a high sensitivity with a limit of detection of 0.002 ng DNA per reaction, equivalent to only 50 copies of the COI gene. The assay is specific to the target in the presence of closely related and co-occurring species, and it is quantitative over five orders of magnitude. We validated the assay using aquarium water samples and further demonstrated its utility on natural eDNA samples collected from locations around the island of Crete where P. miles had been sighted. P. miles was indeed detected in three out of nine locations, two nature reserves and a closed bay. Lack of detection in the remaining locations suggest that populations are still at a low density. We also demonstrate the feasibility of P. miles eDNA qualitative detection directly from the filter used to collect eDNA-containing particles, completely omitting DNA extraction. Overall, we present a new approach for fast and targeted eDNA quantification. The developed LAMP assay together with the quantitative real-time colorimetric detection approach open new possibilities for monitoring invasive P. miles in the field.

ecology↗

Phase Separation of a Nodulin Sec14-like protein Maintains Auxin Efflux Carrier Polarity at Arabidopsis Plasma Membranes

Protein function can be modulated by phase transitions in their material properties, which can range from liquid-to solid-like; yet the mechanisms that drive these transitions and whether they are important for physiology are still unknown. Using the model plant Arabidopsis, we show that developmental robustness is reinforced by phase transitions of the plasma membrane-bound lipid-binding protein SEC14-like. Using imaging, genetics, and in vitro reconstitution experiments, we show that SEC14-like undergoes liquid-like phase separation in the root stem cells. Outside the stem cell niche, SEC14-like associates with the caspase-like protease separase and conserved microtubule motors at unique polar plasma membrane interfaces. In these interfaces, SEC14-like undergoes abrupt processing by separase, which promotes its liquid-to-solid transition. The SEC14-like liquid-to-solid transition is important for root developmental robustness, as lines expressing an uncleavable SEC14-like variant or mutants of separase, and associated microtubule motors show similar developmental phenotypes. Furthermore, the processed and solidified but not the liquid form of SEC14-like interacts with the polar protein PINFORMED2 at the plasma membrane and perhaps other polar proteins of the PINFORMED family. This work demonstrates that robust development can involve abrupt liquid-to-solid transitions mediated by proteolysis at unique plasma membrane interfaces.

cell biology↗

Acoustic array biochip combined with allele-specific PCR for multiple cancer mutation analysis in tissue and liquid biopsy

Regular screening of cancerous point mutations is of importance to cancer management and treatment selection. Although excellent techniques like next generation sequencing and droplet digital PCR are available, these are still lacking in speed, simplicity and cost-effectiveness. Here a new approach is presented where allele-specific PCR (AS-PCR) is combined with a novel High Fundamental Frequency Quartz Crystal Microbalance (HFF-QCM) array biosensor for the amplification and detection, respectively, of cancer point mutations. For the proof-of-concept, the method was applied to the screening of the BRAF V600E and KRAS G12D mutations in spiked-in and clinical samples. Regarding the BRAF target, an analytical sensitivity of 0.01%, i.e., detection of 1 mutant copy of genomic DNA in an excess of 104 wild type molecules, was demonstrated; moreover, quantitative results during KRAS detection were obtained when an optimized assay was employed with a sensitivity of 0.05%. The assays were validated using tissue and plasma samples obtained from melanoma, colorectal and lung cancer patients. Results are in full agreement with Sanger sequencing and droplet digital PCR, demonstrating efficient detection of BRAF and KRAS mutations in samples having an allele frequency below 1%. The high sensitivity and technology-readiness level of the methodology, together with the ability for multiple sample analysis (24 array biochip), cost-effectiveness and compatibility with routine work-flow, hold promise for the implementation of this AS-PCR/acoustic methodology in clinical oncology as a tool for tissue and liquid biopsy.

biophysics↗

Real-time colorimetric LAMP methodology for quantitative nucleic acids detection at the point-of-care

Loop-mediated isothermal amplification is known for its high sensitivity, specificity and tolerance to inhibiting-substances. We developed a device for performing real-time colorimetric LAMP combining the accuracy of lab-based quantitative molecular diagnosis with the simplicity of point-of-care testing. This handheld device employs a single reaction-pot for amplification and a mini-camera for detection. Competitive features are the rapid analysis (<30min), quantification over 9 log-units, crude sample-compatibility (saliva, tissue, swabs), low detection limit (<5copies/reaction), smartphone-operation and fast prototyping (3D-printing). The devices clinical utility is demonstrated in cancer-mutations and COVID-19 testing. Excellent performance includes: detection of 0.01% of BRAF-V600E-to-wild-type molecules; 97% sensitivity to SARS-CoV-2 RNA detection (89 samples); 83% (Ct<34), 98% (Ct<30) and 100% (Ct<25) to 163 nasopharyngeal-swabs; 100% specificity in all cases. The device high technology-readiness-level makes it a suitable platform for performing any colorimetric LAMP assay; moreover, its simple and inexpensive fabrication holds promise for fast deployment and application in global diagnostics.

bioengineering↗