bioRxiv Science⌕ Search

Biology subjects

George, J. A.

Publications and source records attributed to George, J. A..

4 recordsLinked to original sources

Proteomic analysis identifies dysregulated proteins in albuminuria: a South African pilot study

Albuminuria may precede decreases in glomerular filtration rate (GFR) and both tests are insensitive predictors of early stages of kidney disease. Our aim was to characterise the urinary proteome in black African individuals with albuminuria and well-preserved GFR from South Africa. A case-controlled study that compared urinary proteomes of 52 normoalbuminuric (urine albumin: creatinine ratio (uACR) <3 mg/mmol) and 56 albuminuric (uACR [&ge;] 3 mg/mmol) adults of Black African ethnicity. Urine proteins were precipitated, reduced, alkylated, digested, and analysed using an Evosep One LC coupled to a Sciex 5600 Triple-TOF in data-independent acquisition mode. Data were searched on SpectronautTM 15. Differentially abundant proteins (DAPs) were filtered [&ge;] 2.25-fold change and false discovery rate [&le;] 1%. Receiver operating characteristic curves were used to assess the discriminating ability of proteins of interest. Pathway analysis was performed using Enrichr software. The albuminuric group had a higher uACR (7.9 vs 0.55 mg/mmol, p <0.001). The median eGFR (mL/min/1.73m2) showed no difference between the groups (111 vs 114, p=0.707). We identified 80 DAPs in the albuminuria group compared to normoalbuminuria, of which 59 proteins increased while 21 proteins decreased in abundance. We found 12 urinary proteins with AUC > 0.8, and p-value <0.001 in the multivariate analysis. Furthermore, an 80-protein model was developed that showed a high AUC >0.907 and a predictive accuracy of 91.3% between the two groups. Pathway analysis associated with DAPs were involved in insulin growth factor (IGF) functions, innate immunity, platelet degranulation, and extracellular matrix organization. In albuminuric individuals with well-preserved eGFR, pathways involved in preventing the release and uptake of IGF by insulin growth factor binding protein were significantly enriched. These proteins are indicative of a homeostatic imbalance in a variety of cellular processes underlying renal dysfunction and are implicated in chronic kidney disease.

biochemistry↗

Portable Take-Home System Enables Proportional Control and High-Resolution Data Logging with a Multi-Degree-of-Freedom Bionic Arm

This paper describes a portable, prosthetic control system for at-home use of an advanced bionic arm. The system uses a modified Kalman filter to provide 6 degree-of-freedom, real-time, proportional control. We describe (a) how the system trains motor control algorithms for use with an advanced bionic arm, and (b) the systems ability to record an unprecedented and comprehensive dataset of EMG, hand positions and force sensor values. Intact participants and a transradial amputee used the system to perform activities-of-daily-living, including bi-manual tasks, in the lab and at home. This technology enables at-home dexterous bionic arm use, and provides a high-temporal resolution description of daily use--essential information to determine clinical relevance and improve future research for advanced bionic arms.

bioengineering↗

Long-Term Performance of Utah Slanted Electrode Arrays and Intramuscular Electromyographic Leads Implanted Chronically in Human Arm Nerves and Muscles

ObjectiveWe explore the long-term performance and stability of seven percutanous Utah Slanted Electrode Arrays (USEAs) and intramuscular recording leads (iEMGs) implanted chronically in the residual arm nerves and muscles of three human amputees as a means to permanently restore sensorimotor function after upper-limb. ApproachWe quantify the number of functional recording and functional stimulating electrodes over time. We also calculate the signal-to-noise ratio of USEA and iEMG recordings and quantify the stimulation amplitude necessary to evoke detectable sensory percepts. Furthermore, we quantify the consistency of the sensory modality, receptive field location, and receptive field size of USEA-evoked percepts. Main ResultsIn the most recent subject, involving USEAs with technical improvements, neural recordings persisted for 502 days (entire implant duration) and the number of functional recording electrodes for one USEA increased over time. However, for six out of seven USEAs the number of functional recording electrodes decreased within the first two months after implantation. The signal-to-noise ratio of neural recordings and electromyographic recordings stayed relatively consistent over time. Sensory percepts were consistently evoked over the span of 14 months, were not significantly different in size, and highlighted the nerves fascicular organization. The percentage of percepts with consistent modality or consistent receptive field location between sessions (~1 month apart) varied between 0-86.2% and 9.1-100%, respectively. Stimulation thresholds and electrode impedances increased initially but then remained relatively stable over time. SignificanceThis work demonstrates improved performance of USEAs, and provides a basis for comparing the longevity and stability of USEAs to that of other neural interfaces. Although USEAs provide a rich repertoire of neural recordings and sensory percepts, performance still generally declines over time. Future work should leverage the results presented here to further improve USEA design or to develop adaptive algorithms that can maintain a high level of performance.

neuroscience↗

An Adaptable Prosthetic Wrist Reduces Subjective Workload

Many presently available prostheses lack a functional wrist. To fill this niche and to better understand the impact a wrist has in prosthetic functionality, we designed a low-cost, adaptable, 3D-printable prosthetic wrist that can be adapted to various prosthetic hands and sockets. The wrist utilizes inexpensive but powerful servo motors to provide simultaneous and proportional control of two degrees of freedom: pronation/supination and flexion/extension or radial/ulnar deviation. Participants used both our wrist and a commercially available wrist (DEKA \"LUKE\" Arm) to complete a modified version of the clothespin relocation task with and without the wrists enabled. Through use of the NASA Task Load Index we found that both wrists significantly reduced the subjective workload associated with clothespin relocation task (p < 0.05). However, we found no significant difference in task completion speed, presumably due to compensation strategies. This inexpensive and adaptable prosthetic wrist can be used by amputees to reduce task workload, or by researchers to further explore the importance of wrist function.

bioengineering↗