Biomimetic scaffolds mimic human subretinal debris for preclinical testing of prosthetic vision

Photovoltaic subretinal prostheses replace the lost photoreceptors in patients blinded by atrophic age-related macular degeneration (AMD) and provide central vision by electrically stimulating the inner retinal neurons. Subretinal debris in geographic atrophy separate the inner nuclear layer from the implant by tens of micrometers, increasing the stimulation threshold and reducing the pattern contrast. Absence of this separating layer in animal models diminishes the accuracy of preclinical testing of the next-generation implants, especially with smaller pixels. We developed three-dimensional biomimetic scaffolds nanoprinted onto photovoltaic arrays to provide a precisely controlled separation between the implants and target neurons in animal models of retinal degeneration. Gap sizes of the scaffolds were adjusted to meet the following requirements: they should allow light penetration to the implant, provide unobstructed flow of electric current, but preclude migration of cells into their 3-D structure. Gaps of 3 m were found to be optimal as they restricted cellular migration and maintained the inner nuclear layer above both planar and pillar electrode arrays. Scaffolds did not measurably alter the photovoltaic response and accurately reproduced the distance dependence of stimulation threshold. Following implantation, the initially fluid-filled intra-scaffold space was progressively filled by cellular matter matching the density of the subretinal debris. This transition is expected to increase resistivity of the scaffold to that of tissue, which was evidenced by concurrently improved grating acuity. These results establish a model of the controlled separation between the implant and the target neurons reproducing the features of subretinal debris in geographic atrophy of human patients, thereby providing a platform for accurate preclinical evaluation of the subretinal implants.

bioengineering↗

Electrodeposited Biocompatible Coatings for 3D Electrodes on Retinal Prostheses

Photovoltaic subretinal prosthesis, PRIMA, provides central vision to patients blinded by age-related macular degeneration, with acuity matching the 100 m pixel size. Further miniaturization requires pillar electrodes to position the stimulating surfaces closer to the inner retinal neurons. While such structures can be electroplated in gold and coated on their tops with SIROF, the exposed gold sidewalls are not biocompatible. Sputtering or atomic layer deposition of protective coatings are unsuitable for selectively passivating the pillar structures without also coating the photosensitive regions and return electrodes of the implant. Here, we present a strategy for biocompatible coating of pillar sidewalls while preserving surrounding implant functionality. The approach combines non-critical photoresist lithography to protect planar return electrodes with electrodeposition of TiO2; or Pt onto gold pillar sidewalls. In-vivo studies demonstrated that both TiO2 and Pt coatings are biocompatible and prevent adverse reactions of the retinal tissue to gold. Since specific capacitance of electroplated TiO2 (25 F/cm2) is much lower than that of Pt (240 F/cm2), the former better limits the current from the side walls and ensures that charge injection occurs predominantly through the pillar tops coated with SIROF (~6 mF/cm2). Electrodeposition, combined with noncritical photolithography provides a scalable wafer-level solution for fabrication of biocompatible three-dimensional electro-neural interfaces, addressing a critical bottleneck in bioelectronics.

bioengineering↗

Eye-tracked Maxwellian illumination system for power-efficient retinal stimulation

Augmented reality glasses typically have poor optical efficiency (<1%), which is detrimental for high power applications, such as prosthetic vision. Maxwellian view optics are a candidate for increasing efficiency, but suffer from a very limited exit pupil and thus field of view. Many approaches to extend the eyebox inherently decrease the optical power. We present a design that uses a high-density VCSEL array and eye tracking to create an extended eyebox without sacrificing the advantages of a Maxwellian view display. Our system achieves a 20 degree field of view, a resolution 48.8 LP/mm (10 m), and an end-to-end optical efficiency of 83%

bioengineering↗

Titanium and platinum coatings reduce inflammation induced by gold on subretinal prosthesis

Subretinal photovoltaic implants provide central vision to patients blinded by atrophic age-related macular degeneration, with acuity limited by their 100-{micro}m pixels. Higher resolution requires smaller pixels incorporating three-dimensional electrodes, which can be fabricated by gold electroplating. However, the retinal response to exposed gold remains poorly characterized. Here, we evaluated gold biocompatibility on subretinal implants in Royal College of Surgeons rats and compared it with platinum- and titanium-coated surfaces. Although in-vivo optical coherence tomography revealed no overt structural disruption, gold implants induced cellular-scale anomalies, including abnormal morphology of rod bipolar cells, microglial accumulation near the implant, and increased cell death within days after implantation. These effects occurred across flat, pillar, and honeycomb geometries, indicating a material-rather than geometry-dependent response. By contrast, platinum- and titanium-coated implants showed substantially lower loss and morphological disruption of rod bipolar cells, together with markedly reduced microglial activation. These findings indicate that exposed gold surfaces can induce acute retinal inflammation and neuronal loss, whereas conformal platinum or titanium coatings substantially improve biocompatibility. Such coatings enable the development of three-dimensional subretinal prostheses with smaller pixels for improved visual resolution.

bioengineering↗

Amorphous silicon resistors enable smaller pixels in photovoltaic retinal prosthesis

ObjectiveClinical trials of the photovoltaic subretinal prosthesis PRIMA demonstrated feasibility of prosthetic central vision with resolution matching its 100{micro}m pixel size. To improve prosthetic acuity further, pixel size should be decreased. However, there are multiple challenges, one of which is related to accommodating a compact shunt resistor within each pixel that discharges the electrodes between stimulation pulses and helps increase the contrast of the electric field pattern. Unfortunately, standard materials used in integrated circuit resistors do not match the resistivity required for small photovoltaic pixels. Therefore, we used a novel material - doped amorphous silicon (a-Si) and integrated it into photovoltaic arrays with pixel sizes down to 20{micro}m. ApproachTo fit within a few {micro}m2 area of the pixels and provide resistance in the M{Omega} range, the material should have sheet resistance of a few hundred k{Omega}/sq, which translates to resistivity of a few {Omega}*cm. The a-Si layer was deposited by low-pressure chemical vapor deposition (LPCVD) and its resistivity was adjusted by PH3 doping before encapsulating the resistors between SiO2 and SiC for stability in-vivo. Main ResultsHigh-resolution retinal implants with integrated shunt resistors were fabricated with values ranging from 0.75 to 4 M{Omega} on top of the photovoltaic pixels of 55, 40, 30 and 20 {micro}m in size. Photoresponsivity with all pixel sizes was approximately 0.53 A/W, as high as in the arrays with no shunt resistor. The shunts shortened electrodes discharge time, with the average electric potential in electrolyte decreasing by only 21-31% when repetition rate increased from 2 to 30 Hz, as opposed to a 54-55% decrease without a shunt. Similarly, contrast of a Landolt C pattern increased from 16-22% with no shunt to 22-34% with a shunt. Further improvement in contrast is expected with pillar electrodes and local returns within each pixel. SignificanceMiniature shunt resistors in a MOhm range can be fabricated from doped a-Si in a process compatible with manufacturing of photovoltaic arrays. The shunt resistors improved current injection and spatial contrast at video frame rates, without compromising the photoresponsivity. These advances are critical for scaling pixel sizes below 100 {micro}m to improve visual acuity of prosthetic vision.

neuroscience↗

Enhancing Prosthetic Vision by Upgrade of a Subretinal Photovoltaic Implant in situ

In patients with atrophic age-related macular degeneration, subretinal photovoltaic implant (PRIMA) provided visual acuity up to 20/440, matching its 100m pixels size. Next-generation implants with smaller pixels should significantly improve the acuity. This study in rats evaluates removal of a subretinal implant, replacement with a newer device, and the resulting grating acuity in-vivo. Six weeks after the initial implantation with planar and 3-dimensional devices, the retina was re-detached, and the devices were successfully removed. Histology demonstrated a preserved inner nuclear layer. Re-implantation of new devices into the same location demonstrated retinal re-attachment to a new implant. New devices with 22m pixels increased the grating acuity from the 100m capability of PRIMA implants to 28m, reaching the limit of natural resolution in rats. Reimplanted devices exhibited the same stimulation threshold as for the first implantation of the same implants in a control group. This study demonstrates the feasibility of safely upgrading the subretinal photovoltaic implants to improve prosthetic visual acuity.

neuroscience↗

Three-dimensional electro-neural interfaces electroplated on subretinal prostheses

ObjectiveHigh-resolution retinal prosthetics offer partial restoration of sight to patients blinded by retinal degenerative diseases through electrical stimulation of the remaining neurons. Decreasing the pixel size enables an increase in prosthetic visual acuity, as demonstrated in animal models of retinal degeneration. However, scaling down the size of planar pixels is limited by the reduced penetration depth of the electric field in tissue. We investigate 3-dimensional structures on top of the photovoltaic arrays for enhanced penetration of electric field to permit higher-resolution implants. ApproachWe developed 3D COMSOL models of subretinal photovoltaic arrays that accurately quantify the device electrodynamics during stimulation and verified it experimentally through comparison with the standard (flat) photovoltaic arrays. The models were then applied to optimise the design of 3D electrode structures (pillars and honeycombs) to efficiently stimulate the inner retinal neurons. The return electrodes elevated on top of the honeycomb walls surrounding each pixel orient the electric field inside the cavities vertically, aligning it with bipolar cells for optimal stimulation. Alternatively, pillars elevate the active electrode into the inner nuclear layer, improving proximity to the target neurons. Modelling results informed a microfabrication process of electroplating the 3D electrode structures on top of the existing flat subretinal prosthesis. Main resultsSimulations demonstrate that despite the conductive sidewalls of the 3D electrodes being exposed to electrolyte, most of the charge flows via the high-capacitance sputtered Iridium Oxide film that caps the top of the 3D structures. The 24 {micro}m height of the electroplated honeycomb structures was optimised for integration with the inner nuclear layer cells in rat retina, while 35 {micro}m height of the pillars was optimized for penetrating the debris layer in human patients. Release from the wafer and implantation of the 3D arrays demonstrated that they are mechanically robust to withstand the associated forces. Histology demonstrated successful integration of the 3D structures with the rat retina in-vivo. SignificanceElectroplated 3D honeycomb structures produce a vertically oriented electric field that offers low stimulation threshold, high spatial resolution and high contrast for the retinal implants with pixel sizes down to 20{micro}m in width. Pillar electrodes offer an alternative configuration for extending the stimulation past the debris layers. Electroplating of the 3D structures is compatible with the fabrication process of the flat photovoltaic arrays, thereby enabling much more efficient stimulation than in their original flat configuration.

neuroscience↗

3D electronic implants in subretinal space: long-term follow-up in rodents

Photovoltaic subretinal prosthesis (PRIMA) enables restoration of sight via electrical stimulation of the interneurons in degenerated retina, with resolution limited by the 100 m pixel size. Since decreasing the pixel size below 75 m in the current bipolar geometry is impossible, we explore the possibility of using smaller pixels based on a novel 3-dimensional honeycomb-shaped design. We assessed the long-term biocompatibility and stability of these arrays in rats by investigating the anatomical integration of the retina with flat and 3D implants and response to electrical stimulation over lifetime - up to 9 months post-implantation in aged rats. With both flat and 3D implants, VEP amplitude decreased after the day of implantation by more than 3-fold, and gradually recovered over about 3 months. With 25 m high honeycomb walls, the majority of bipolar cells migrate into the wells, while amacrine and ganglion cells remain above the cavities, which is essential for selective network-mediated stimulation of the second-order neurons. Retinal thickness and full-field stimulation threshold with 40 m-wide honeycomb pixels were comparable to those with planar devices - 0.05 mW/mm2 with 10ms pulses. However, fewer cells from the inner nuclear layer migrated into the 20 m-wide wells, and stimulation threshold increased over 5 months, before stabilizing at about 0.08 mW/mm2. Such threshold is significantly lower than 1.8 mW/mm2 with a previous design of flat bipolar pixels, confirming the promise of the 3D honeycomb-based approach to high resolution subretinal prosthesis.

neuroscience↗

Cellular integration with a subretinal honeycomb-shaped prosthesis

In patients blinded by geographic atrophy, subretinal photovoltaic implant with 100{micro}m pixels provided visual acuity closely matching the pixel pitch. However, such flat bipolar pixels cannot be scaled below 75{micro}m, limiting the attainable visual acuity. This limitation can be overcome by shaping the electric field with 3-dimensional electrodes. In particular, elevating the return electrode on top of honeycomb-shaped vertical walls surrounding each pixel extends the electric field vertically and decouples its penetration into tissue from the pixel width. This approach relies on migration of the retinal cells into the honeycomb wells. Here, we demonstrate that the majority of the inner retinal neurons migrate into 25{micro}m deep wells, leaving the third-order neurons, such as amacrine and ganglion cells, outside. This is important for selective stimulation of the second-order neurons to preserve the retinal signal processing in prosthetic vision. Comparable glial response to that with flat implants suggests that migration and separation of the retinal cells by the walls does not cause additional stress. Furthermore, retinal migration into the honeycombs does not negatively affect its electrical excitability.

neuroscience↗

Electronic "photoreceptors" enable prosthetic vision with acuity matching the natural resolution in rats

Localized stimulation of the inner retinal neurons for high-acuity prosthetic vision requires small pixels and minimal cross-talk from neighboring electrodes. Local return electrodes within each pixel limit crosstalk, but can over-constrain the electric field, thus precluding efficient stimulation with subretinal pixels smaller than 50 m. Here we demonstrate high-resolution prosthetic vision based on a novel design of a photovoltaic array, where field confinement is achieved dynamically, leveraging the adjustable conductivity of the diodes under forward bias to turn the designated pixels into transient returns. We validated computational modeling of the field confinement in such an optically-controlled circuit by ex-vivo and in-vivo measurements. Most importantly, using this strategy, we demonstrated that the grating acuity with 40 m pixels matches the pixel pitch, while with 20 m pixels, it reaches the 28 m limit of the natural visual resolution in rats. This method enables customized field shaping based on individual retinal thickness and distance from the implant, paving the way to prosthetic vision with acuity as high as 20/80 in atrophic macular degeneration.

bioengineering↗

Vertical-junction Photodiodes for High-resolution Retinal Prostheses

ObjectiveTo restore central vision in patients with atrophic age-related macular degeneration, we replace the lost photoreceptors with photovoltaic pixels, which convert light into current and stimulate the secondary retinal neurons. Clinical trials demonstrated prosthetic acuity closely matching the sampling limit of the 100 m pixels, and hence smaller pixels are required for improving visual acuity. However, with smaller flat bipolar pixels, the electric field penetration depth and the photodiode responsivity significantly decrease, making the device inefficient. Smaller pixels may be enabled (1) by increasing the diode responsivity using vertical p-n junctions and (2) by directing the electric field vertically using 3-D electrodes. Here, we demonstrate such novel photodiodes and test the retinal stimulation in a vertical electric field. ApproachArrays of silicon photodiodes of 55, 40, 30, and 20 m in width, with vertical p-n junctions, were fabricated. The electric field in the retina was directed vertically by a common return electrode at the edge of the devices. Optical and electronic performance of the diodes was characterized in-vitro, and retinal stimulation threshold measured by recording the visually evoked potentials (VEPs) in rats with retinal degeneration. Main resultsThe photodiodes exhibited sufficiently low dark current (<10 pA) and responsivity at 880 nm wavelength as high as 0.51 A/W, with 85% internal quantum efficiency, independent of pixel size. Field mapping in saline demonstrated uniformity of the pixel performance in the array. The full-field stimulation threshold was as low as 0.057{+/-}0.029 mW/mm2 with 10 ms pulses, independent of pixel size. SignificancePhotodiodes with vertical p-n junctions demonstrated excellent charge collection efficiency independent of pixel size, down to 20 m. Vertically-oriented electric field provides a stimulation threshold that is independent of pixel size. These results are the first steps in validation of the feasibility of scaling down the photovoltaic pixels for subretinal stimulation.

bioengineering↗