bioRxiv Science⌕ Search

Biology subjects

Fisher, L. E.

Publications and source records attributed to Fisher, L. E..

15 recordsLinked to original sources

SpIC3D imaging: Spinal In-situ Contrast 3D imaging

High-definition visualization techniques are critical for understanding the neuroanatomy of the spinal cord, an essential structure for sensorimotor and autonomic functions, in both healthy and pathological conditions. Magnetic resonance imaging (MRI) is a common method for visualizing neural structures in 3D. However, techniques for spinal cord MRI have historically achieved limited visualization of rootlets and nerves, especially at lower spinal levels, due to their highly complex and compact organization. Here we developed a spinal in-situ contrast 3D imaging (SpIC3D) method that allows visualization of spinal compartments in fixed animal and human specimens with ultra-high resolution at various spinal levels. Using SpIC3D, we achieved quantification of neuronal cell density in dorsal root ganglia, multi-segment identification of individual rootlets and roots, and volumetric reconstruction of multiple spinal structures for computational modeling. SpIC3D provides a basis for accelerated spinal pathology characterization and personalized spinal cord stimulation treatments.

neuroscience↗

High-frequency amplitude-modulated sinusoidal stimulation induces desynchronized yet controllable neural firing

Regaining sensory feedback is critical for people living with limb amputation. Electrical stimulation of sensory fibers in peripheral nerves has been shown to restore focal percepts in the missing limb. However, conventional rectangular current pulses induce sensations often described as unnatural, likely due to the synchronous and periodic nature of activity they evoke. Here we introduce a fast-oscillating amplitude-modulated sinusoidal (FAMS) stimulation waveform that desynchronizes neural activity. Using computational modeling, we show that sinusoidal waveforms evoke asynchronous and irregular firing patterns, with frequency-dependent effects. Leveraging both low- and high-frequency mechanisms, FAMS exploits membrane nonlinearities to enhance neuron-specific differences. In a feline model of peripheral nerve stimulation, FAMS evoked activity that was more asynchronous than conventional rectangular pulses, while remaining easily controllable with simple stimulation parameters. Importantly, in human experiments using noninvasive stimulation of the median nerve, participants reported that FAMS evoked more natural sensations compared to rectangular biphasic pulses in a two-alternative forced-choice task. The preference for FAMS increased at higher intensities above sensory threshold, despite intensity-matched stimulation across waveform types. These findings provide evidence that reduced synchrony in afferent recruitment translates into more naturalistic and comfortable sensory percepts. Together, our results establish FAMS as a promising biomimetic stimulation strategy with potential for clinical applications in sensory feedback restoration. One Sentence SummaryA new electrical stimulation waveform allows for evoking and controlling more naturalistic neural activity than can be achieved with traditional stimulation waveforms.

bioengineering↗

Computational modeling of dorsal root ganglion stimulation using an Injectrode

ObjectiveMinimally invasive neuromodulation therapies like the Injectrode, which is composed of a tightly wound polymer-coated platinum/iridium microcoil, offer a low-risk approach for administering electrical stimulation to the dorsal root ganglion (DRG). This flexible electrode is aimed to conform to the DRG. The stimulation occurs through a transcutaneous electrical stimulation (TES) patch, which subsequently transmits the stimulation to the Injectrode via a subcutaneous metal collector. However, effectiveness of stimulation relies on the specific geometrical configurations of the Injectrode-collector-patch system. Hence, there is a need to investigate which design parameters influence the activation of targeted neural structures. ApproachWe employed a hybrid computational modeling approach to analyze the impact of the Injectrode system design parameters on charge delivery and the neural response to stimulation. We constructed multiple finite element method models of DRG stimulation and multi-compartment models of DRG neurons. We simulated the neural responses using parameters based on prior acute preclinical experiments. Additionally, we developed multiple human-scale computational models of DRG stimulation to investigate how design parameters like Injectrode size and orientation influenced neural activation thresholds. Main resultsOur findings were in accordance with acute experimental measurements and indicated that the Injectrode system predominantly engages large-diameter afferents (A{beta}-fibers). These activation thresholds were contingent upon the surface area of the Injectrode. As the charge density decreased due to increasing surface area, there was a corresponding expansion in the stimulation amplitude range before triggering any pain-related mechanoreceptor (A{delta}-fibers) activity. SignificanceThe Injectrode demonstrates potential as a viable technology for minimally invasive stimulation of the DRG. Our findings indicate that utilizing a larger surface area Injectrode enhances the therapeutic margin, effectively distinguishing the desired A{beta} activation from the undesired A{delta}-fiber activation.

bioengineering↗

Spatially resolved molecular analysis of host response to medical device implantation using the 3D OrbiSIMS

A key goal for implanted medical devices is that they do not elicit a detrimental immune response. Macrophages play critical roles in modulation of the host immune response and are the major cells responsible for persistent inflammatory reactions to implanted biomaterials. We investigate two novel immune-instructive polymers that stimulate pro- or anti-inflammatory responses from macrophages in vitro. These also modulate in vivo foreign body responses (FBR) when implanted subcutaneously in mice as coatings on biomedical grade silicone rubber. The tissue surrounding the implant is mechanically sectioned and imaged to assess the response of the polymers compared to silicone rubber. Immunofluorescent staining reveals responses consistent with pro- or anti-inflammatory responses previously described for these polymers. We apply 3D OrbiSIMS analysis to provide spatial analysis of the metabolite signature in the tissue surrounding the implant for the first time, providing molecular histology insight into the metabolite response in the host tissue. For the pro-inflammatory coating, monoacylglycerols (MG) and diacylglycerols (DG) are observed at increased intensity, while for the anti-inflammatory coating the number of phospholipid species detected decrease and pyridine and pyrimidine levels were elevated. These findings link to observations of small molecule signature from single cell studies of M2 macrophages in vitro where cell and tissue ion intensities were found to correlate suggesting potential for prediction. This illustrates the power of metabolite characterization by the 3D OrbiSIMS to gain insight into the mechanism of bio-instructive materials as medical devices and to inform on the FBR to biomaterials.

bioengineering↗

Anesthesia suppressed gastric myoelectric power in the ferret

BackgroundGastrointestinal myoelectric signals have been the focus of extensive research; although it is unclear how general anesthesia affects these signals, studies have often been conducted under general anesthesia. Here, we explore this issue directly by recording gastric myoelectric signals during awake and anesthetized states in the ferret and also explore the contribution of behavioral movement to observed changes in signal power. MethodsFerrets were surgically implanted with electrodes to record gastric myoelectric activity from the serosal surface of the stomach, and, following recovery, were tested in awake and isoflurane-anesthetized conditions. Video recordings were also analyzed during awake experiments to compare myoelectric activity during behavioral movement and rest. Key ResultsA significant decrease in gastric myoelectric signal power was detected under isoflurane anesthesia compared to the awake condition. Moreover, a detailed analysis of the awake recordings indicates that behavioral movement is associated with increased signal power compared to rest. Conclusions & InferencesThese results suggest that both general anesthesia and behavioral movement can affect the amplitude of gastric myoelectric. In summary, caution should be taken in studying myoelectric data collected under anesthesia. Further, behavioral movement could have an important modulatory role on these signals, affecting their interpretation in clinical settings.

neuroscience↗

Reduced local mechanical stimuli in spaceflight diminishes osteocyte lacunar morphometry and spatial heterogeneity in mouse cortical bone

Three-dimensional (3D) imaging of osteocyte lacunae has recently substantiated the connection between lacunar shape and size, and osteocyte age, viability, and mechanotransduction. Yet it remains unclear why individual osteocytes reshape their lacunae and how networks of osteocytes change in response to local alterations in mechanical loads. We evaluated the effects of local mechanical stimuli on osteocyte lacunar morphometrics in tibial cortical bone from young female mice flown on the Space Shuttle for [~]13 days. We optimized scan parameters, using a laboratory-based submicrometer-resolution X-Ray Microscope, to achieve large [~] 0.3 mm3 fields of view with sufficient resolution ([≥] 0.3 m) to visualize and measure thousands of lacunae per scan. Our novel approach avoids large measurement errors that are inherent in 2D and enables a facile 3D solution as compared to the lower resolution from benchtop micro-computed tomography (CT) systems or the cost and inaccessibility of synchrotron-based CT. Osteocyte lacunae were altered following microgravity exposure in a region-specific manner: more elongated (+7.0% Stretch) in predominately tensile-loaded bone as compared to those in compressively-loaded regions. In compressively-loaded bone, lacunae formed in microgravity were significantly larger (+6.9% Volume) than in the same region formed on Earth. We also evaluated lacunar heterogeneity (i.e., spatial autocorrelation of lacunar morphometric parameters) via kriging models. These statistical models demonstrated that heterogeneity varied with underlying spatial contributors, i.e. the local mechanical and biological environment. Yet in the absence of gravitational loading, osteocyte lacunae in newly formed bone were larger and were collectively more homogenous than in bone formed on Earth. Overall, this study shows that osteocyte reshape their lacunae in response to changes, or absence, in local mechanical stimuli and different biological environments. Additionally, spatial relationships among osteocytes are complex and necessitate evaluation in carefully selected regions of interest and of large cell populations. GRAPHICAL ABSTRACT O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=86 SRC="FIGDIR/small/474962v1_ufig1.gif" ALT="Figure 1"> View larger version (37K): org.highwire.dtl.DTLVardef@f3cc2aorg.highwire.dtl.DTLVardef@1e0fbbdorg.highwire.dtl.DTLVardef@1af3f7dorg.highwire.dtl.DTLVardef@7133b0_HPS_FORMAT_FIGEXP M_FIG C_FIG

bioengineering↗

Augmented Transcutaneous Stimulation Using an Injectable Electrode

Minimally invasive neuromodulation technologies seek to marry the neural selectivity of implantable devices with the low-cost and non-invasive nature of transcutaneous electrical stimulation (TES). The Injectrode(R) is a needle-delivered electrode that is injected onto neural structures under image guidance. Power is then transcutaneously delivered to the Injectrode using surface electrodes. The Injectrode serves as a low-impedance conduit to guide current to the deep on-target nerve, reducing activation thresholds by an order of magnitude compared to using only surface stimulation electrodes. To minimize off-target recruitment of cutaneous fibers, the energy transfer efficiency from the surface electrodes to the Injectrode must be optimized. TES energy is transferred to the Injectrode through both capacitive and resistive mechanisms. Electrostatic finite element models generally used in TES research consider only the resistive means of energy transfer by defining tissue conductivities. Here, we present an electroquasistatic model, taking into consideration both the conductivity and permittivity of tissue, to understand transcutaneous power delivery to the Injectrode. The model was validated with measurements taken from (n=4) swine cadavers. We used the validated model to investigate system and anatomic parameters that influence the coupling efficiency of the Injectrode energy delivery system. Our work suggests the relevance of electroquasistatic models to account for capacitive charge transfer mechanisms when studying TES, particularly when high-frequency voltage components are present, such as those used for voltage-controlled pulses and sinusoidal nerve blocks.

bioengineering↗

Stimulation of the Dorsal Root Ganglion using an Injectrode

ObjectiveThe goal of this work was to compare afferent fiber recruitment by dorsal root ganglion (DRG) stimulation using an injectable polymer electrode (Injectrode(R)) and a more traditional cylindrical metal electrode. ApproachWe exposed the L6 and L7 DRG in four cats via a partial laminectomy or burr hole. We stimulated the DRG using an Injectrode or a stainless steel electrode using biphasic pulses at three different pulse widths (80, 150, 300 s) and pulse amplitudes spanning the range used for clinical DRG stimulation. We recorded antidromic evoked compound action potentials (ECAPs) in the sciatic, tibial, and common peroneal nerves using nerve cuffs. We calculated the conduction velocity of the ECAPs and determined the charge-thresholds and recruitment rates for ECAPs from A, A{beta}, and A{delta} fibers. We also performed electrochemical impedance spectroscopy measurements for both electrode types. Main ResultsThe ECAP thresholds for the Injectrode did not differ from the stainless steel electrode across all primary afferents (A, A{beta}, A{delta}) and pulse widths; charge-thresholds increased with wider pulse widths. Thresholds for generating ECAPs from A{beta} fibers were 100.0 {+/-} 32.3 nC using the stainless steel electrode, and 90.9 {+/-} 42.9 nC using the Injectrode. The ECAP thresholds from the Injectrode were consistent over several hours of stimulation. The rate of recruitment was similar between the Injectrodes and stainless steel electrode and decreased with wider pulse widths. SignificanceThe Injectrode can effectively excite primary afferents when used for DRG stimulation within the range of parameters used for clinical DRG stimulation. The Injectrode can be implanted through minimally invasive techniques while achieving similar neural activation to conventional electrodes, making it an excellent candidate for future DRG stimulation and neuroprosthetic applications.

bioengineering↗

High-density spinal cord stimulation selectively activates lower urinary tract afferents

Epidural spinal cord stimulation (SCS) has recently been reported as a potential intervention to improve limb and autonomic functions, with lumbar stimulation improving locomotion and thoracic stimulation regulating blood pressure. We asked whether sacral SCS could be used to target the lower urinary tract. Here we show that high-density epidural SCS over the sacral spinal cord and cauda equina of anesthetized cats evokes responses in nerves innervating the bladder and urethra and that these nerves can be activated selectively. Sacral epidural SCS always recruited the pelvic and pudendal nerves and selectively recruited these nerves in all but one animal. Individual branches of the pudendal nerve were always recruited as well. Electrodes that selectively recruited specific peripheral nerves were spatially clustered on the arrays, suggesting anatomically organized sensory pathways. This selective recruitment demonstrates a mechanism to directly modulate bladder and urethral function through known reflex pathways, which could be used to restore bladder and urethral function after injury or disease.

bioengineering↗

Tuning electrical stimulation of the cervical vagus nerve for abdominal signaling while reducing cardiovascular side effects

Electrical vagus nerve stimulation (VNS) has the potential to treat a wide variety of diseases by modulating afferent and efferent communication to the heart, lungs, esophagus, stomach, and intestines. Although distal vagal nerve branches, close to end organs, could provide a selective therapeutic approach, these locations are often surgically inaccessible. In contrast, the cervical vagus nerve has been targeted for decades using surgically implantable cuff electrodes to treat epileptic seizures and depression; however, to date, clinical implementation of VNS has relied on an electrode with contacts that fully wrap around the nerve, producing non-selective activation of the entire nerve. Here we demonstrate selective cervical VNS using cuff electrodes with multiple contacts around the nerve circumference to target different functional pathways. These flexible probes were adjusted to the diameter of the nerve using an adhesive hydrogel wrap to create a robust electrode interface. Our approach was verified in a rat model by demonstrating that cervical VNS produces neural activity in the abdominal vagus nerve while limiting effects on the cardiovascular system (i.e., changes in heart rate or blood pressure). This study demonstrates the potential for selective cervical VNS as a therapeutic approach for modulating distal nerve branches while reducing off target effects. This methodology could potentially be refined to treat gastrointestinal, metabolic, inflammatory, cardiovascular, and respiratory diseases amenable to vagal neuromodulatory control.

neuroscience↗

Functional and Structural Moment Arm Validation for Musculoskeletal Models: A Study of the Human Forearm and Hand

The development of realistic musculoskeletal models is a fundamental goal for the theoretical progress in sensorimotor control and its engineering applications, e.g., in the biomimetic control of artificial limbs. Yet, accurate models require extensive experimental measures to validate structural and functional parameters describing muscle state over the full physiological range of motion. However, available experimental measurements of, for example, muscle moment arms are sparse and often disparate. Validation of these models is not trivial because of the highly complex anatomy and behavior of human limbs. In this study, we developed a method to validate and scale kinematic muscle parameters using posture-dependent moment arm profiles, isometric force measurements, and a computational detection of assembly errors. We used a previously published model with 18 degrees of freedom (DOFs) and 32 musculotendon actuators with force generated from a Hill-type muscle model. The muscle path from origin to insertion with wrapping geometry was used to model the muscle lengths and moment arms. We simulated moment arm profiles across the full physiological range of motion and compared them to an assembled dataset of published and merged experimental profiles. The muscle paths were adjusted using custom metrics based on root-mean-square and correlation coefficient of the difference between simulated and experimental values. Since the available measurements were sparse and the examination of high-dimensional muscles is challenging, we developed analyses to identify common failures, i.e., moment arm functional flipping due to the sign reversal in simulated moments and the imbalance of force generation between antagonistic groups in postural extremes. The validated model was used to evaluate the expected errors in torque generation with the assumption of constant instead of the posture-dependent moment arms at the wrist flexion-extension DOF, which is the critical joint in our model with the largest number of crossing muscles. We found that there was a reduction of joint torques by about 35% in the extreme quartiles of the wrist DOF. The use of realistic musculoskeletal models is essential for the reconstruction of hand dynamics. These models may improve the understanding of muscle actions and help in the design and control of artificial limbs in future applications. New & NoteworthyRealistic models of human limbs are a development goal required for the understanding of motor control and its applications in biomedical fields. However, developing accurate models is restrained by the lack of accurate and reliable musculoskeletal measurements in humans. Here, we have overcome this challenge by using multi-stage validation of simulated structures using both experimental data and the identification of structural failures in the high-dimensional muscle paths. We demonstrate that the rigorous structural and functional validation method is essential for the understanding of force generation at the wrist.

neuroscience↗

Heuristic Spike Sorting Tuner (HSST), a framework to determine optimal parameter selection for a generic spike sorting algorithm

Bj[a]nes DA, Fisher LE, Gaunt RA, Weber DJHeuristic Spike Sorting Tuner (HSST), a framework to determine optimal parameter selection for a generic spike sorting algorithm. bioRxiv First published May 21, 2020. Extracellular microelectrodes frequently record neural activity from more than one neuron in the vicinity of the electrode. The process of labeling each recorded spike waveform with the identity of its source neuron is called spike sorting and is often approached from an abstracted statistical perspective. However, these approaches do not consider neurophysiological realities and may ignore important features that could improve the accuracy of these methods. Further, standard algorithms typically require selection of at least one free parameter, which can have significant effects on the quality of the output. We describe a Heuristic Spike Sorting Tuner (HSST) that determines the optimal choice of the free parameters for a given spike sorting algorithm based on the neurophysiological qualification of unit isolation and signal discrimination. A set of heuristic metrics are used to score the output of a spike sorting algorithm over a range of free parameters resulting in optimal sorting quality. We demonstrate that these metrics can be used to tune parameters in several spike sorting algorithms. The HSST algorithm shows robustness to variations in signal to noise ratio, number and relative size of units per channel. Moreover, the HSST algorithm is computationally efficient, operates unsupervised, and is parallelizable for batch processing. NEW & NOTEWORTHYHSST incorporates known neurophysiological priors of extracellular neural recordings while simultaneously taking advantage of powerful abstract mathematical tools. Rather than simply selecting free parameters prior to running a sorting algorithm, HSST executes a sorting algorithm across a range of input parameters, using heuristic metrics to detect which spike-sorting output is most physiologically plausible. This novel approach enables unsupervised spike-sorting exceeding the performance of previous methods, thereby enabling the processing of large data sets with confidence.

neuroscience↗

The effect of wrist posture on extrinsic finger muscle activity during single joint movements

Wrist posture impacts the muscle lengths and moment arms of the extrinsic finger muscles that cross the wrist. As a result, the electromyographic (EMG) activity associated with digit movement at different wrist postures may also change. Therefore, we sought to quantify the posture-dependence of extrinsic finger muscle activity. Fine-wire bipolar electrodes were inserted in the extrinsic hand muscles of able-bodied subjects to record EMG activity during wrist and finger movements in various postures. EMG activity of all the recorded finger muscles were significantly different (p<.05, ANOVA) when performing the same movement in five different wrist postures. EMG activity varied by up to 70%, with the highest levels of activity observed in finger extensors when the wrist was extended. Similarly, finger flexors were most active when the wrist was flexed. For the finger flexors, EMG variations with wrist posture were most prominent for index finger muscles, while the EMG activity of all finger extensor muscles were similarly modulated. The extrinsic finger muscles also showed significant activity during wrist movements with the digits held still regardless of finger posture, suggesting that they may play a role in generating torque during wrist movements. Finally, we developed a pair of generalized classifiers that show that finger muscle EMG can be used to predict wrist posture. These results may impact the design of biomimetic control algorithms for myoelectric prosthetic hands, but further work in transradial amputees is necessary to determine whether this phenomenon persists after amputation.

bioengineering↗

Approximating complex musculoskeletal biomechanics using multidimensional autogenerating polynomials

Computational models of the musculoskeletal system are scientific tools used to study human movement, quantify the effects of injury and disease, and plan surgical interventions. Additionally, these models could also be used to intuitively link biological control signals and realistic high-dimensional articulated prosthetic limbs. However, implementing fast and accurate musculoskeletal computations that can be used to control a prosthetic limb in real-time is a challenging problem. As muscles typically span multiple joints, the wrapping over complex geometrical constraints changes their moment arms and length as a function of joint angle and, thus, their ability to generate joint torques. As a result of these biomechanical complexities, calculating these muscle state variables in real-time is a difficult simulation problem. Here, we report a method to accurately and efficiently calculate these variables for the forearm muscles that actuate the hand and wrist across multiple postures. The posture dependent muscle geometry, moment arms and lengths of modeled muscles, were captured using autogenerating polynomials that expanded their optimal selection of terms using information measurements. The iterative process approximated 33 musculotendon actuators, each spanning up to 6 DOFs in an 18 DOF model of the human arm and hand, defined over the full physiological range of motion. Using these polynomials, the entire forearm anatomy could be computed in <10 {micro}s, which is far better than what is required for real-time performance, and with low errors in moment arms (below 5%) and lengths (below 0.4%). Moreover, we demonstrate that the number of elements in these autogenerating polynomials does not increase exponentially with the increase in complexity of muscles, increasing linearly instead. The similar structure and function of muscles are represented with specific invariant polynomial terms. Dimensionality reduction using the polynomial terms alone resulted in clusters comprised of muscles with similar functions, suggesting that the polynomials themselves captured biologically relevant features of muscle structure and function. We propose that this novel method of describing musculoskeletal biomechanics might further improve the applications of detailed and scalable models for the description of human movement.

physiology↗

Machine learning prediction of emesis and gastrointestinal state in ferrets

Although electrogastrography (EGG) could be a critical tool in the diagnosis and treatment of patients with gastrointestinal (GI) disease, it remains under-utilized. The lack of spatial and temporal resolution using current EGG methods presents a significant roadblock to more widespread usage. Human and preclinical studies have shown that GI myoelectric electrodes can record signals containing significantly more information than can be derived abdominal surface electrodes. The current study sought to assess the efficacy of multi-electrode arrays, surgically implanted on the serosal surface of the GI tract, from gastric fundus to duodenum, in recording myoelectric signals. It also examines the potential for machine learning algorithms to predict functional states, such as retching and emesis, from GI signal features. Studies were performed using ferrets, a gold standard model for emesis testing. Our results include simultaneous recordings from up to six GI recording sites in both anesthetized and chronically implanted free-moving ferrets. Testing conditions to produce different gastric states included gastric distension, intragastric infusion of emetine (a prototypical emetic agent), and feeding. Despite the observed variability in GI signals, machine learning algorithms, including k nearest neighbors and support vector machines, were able to detect the state of the stomach with high overall accuracy (>80%). The present study is the first demonstration of machine learning algorithms to detect the physiological state of the stomach and onset of retching and could provide insight into methodologies to treat GI diseases and control symptoms such as nausea and vomiting.

neuroscience↗