bioRxiv Science⌕ Search

Biology subjects

Ferrarelli, F.

Publications and source records attributed to Ferrarelli, F..

3 recordsLinked to original sources

Recognizing EEG responses to active TMS vs. sham stimulations in different TMS-EEG datasets: a machine learning approach

BackgroundTranscranial Magnetic Stimulation (TMS) with simultaneous Electroencephalogram (TMS-EEG) allows assessing the neurophysiological properties of cortical neurons. However, TMS-evoked EEG potentials (TEPs) can be affected by components unrelated to TMS direct neuronal activation. Accurate, automatic tools are therefore needed to establish the quality of TEPs. ObjectiveTo assess the discriminability of EEG responses to TMS vs. EEG responses to sham stimulations using sequence-to-sequence machine learning (ML). MethodsTwo indipendent TMS-EEG datasets including TMS and several sham stimulation conditions were obtained from the left motor area of healthy volunteers (N=33 across datasets). A Bi-directional Long Short-Term Memory (BiLSTM) ML network was used to label each time point of the EEG signals as pertaining to TMS or sham conditions. Main outcome measures included accuracy at single-trial level and after averaging five to twenty trials. ResultsFor TMS conditions, post-stimulus vs. baseline/pre-stimulus EEG comparisons yielded moderate (60%-75%) single-trial accuracy and high-accuracy (>75%) for 20 trials across datasets, while for sham conditions post- vs. baseline/pre-stimulus EEG comparisons yielded lower accuracy rates than for TMS conditions, except for unmasked auditory stimulation. Furthermore, baseline/pre-stimulus TMS vs. baseline/pre-stimulus sham EEG comparisons showed chance-level accuracy, whereas post-stimulus TMS vs. post-stimulus sham EEG comparisons had moderate (single trial) to high (20 trial) accuracy, except for TMS with and without the click noise masking. Single-subject findings were comparable to group-level results across datasets. ConclusionsTEPs after active TMS are discernible from various sham stimulations even after a handful of trials and at the single-subject level using a BiLSTM ML approach.

neuroscience↗

Bridging Big Data: Procedures for Combining Non-equivalent Cognitive Measures from the ENIGMA Consortium

Investigators in neuroscience have turned to Big Data to address replication and reliability issues by increasing sample sizes, statistical power, and representativeness of data. These efforts unveil new questions about integrating data arising from distinct sources and instruments. We focus on the most frequently assessed cognitive domain - memory testing - and demonstrate a process for reliable data harmonization across three common measures. We aggregated global raw data from 53 studies totaling N = 10,505 individuals. A mega-analysis was conducted using empirical bayes harmonization to remove site effects, followed by linear models adjusting for common covariates. A continuous item response theory (IRT) model estimated each individuals latent verbal learning ability while accounting for item difficulties. Harmonization significantly reduced inter-site variance while preserving covariate effects, and our conversion tool is freely available online. This demonstrates that large-scale data sharing and harmonization initiatives can address reproducibility and integration challenges across the behavioral sciences. TeaserWe present a global effort to devise harmonization procedures necessary to meaningfully leverage big data.

neuroscience↗

The Spectral Features Of EEG Responses To Transcranial Magnetic Stimulation Of The Primary Motor Cortex Depend On The Amplitude Of The Motor Evoked Potentials

Transcranial magnetic stimulation (TMS) of the primary motor cortex (M1) can excite both cortico-cortical and cortico-spinal axons resulting in TMS-evoked potentials (TEPs) and motor-evoked potentials (MEPs), respectively. Despite this remarkable difference with other cortical areas, the influence of motor output and its amplitude on TEPs is largely unknown. Here we studied TEPs resulting from M1 stimulation and assessed whether their waveform and spectral features depend on the MEP amplitude. To this aim, we performed two separate experiments. In experiment 1, single-pulse TMS was applied at the same supra-threshold intensity on primary motor, prefrontal, premotor and parietal cortices and the corresponding TEPs were compared by means of local mean field power and time-frequency spectral analysis. In experiment 2 we stimulated M1 at resting motor threshold in order to elicit MEPs characterized by a wide range of amplitudes. TEPs computed from high-MEP and low-MEP trials were then compared using the same methods applied in experiment 1. In line with previous studies, TMS of M1 produced larger TEPs compared to other cortical stimulations. Notably, we found that only TEPs produced by M1 stimulation were accompanied by a late ([~]300 ms after TMS) event-related desynchronization (ERD), whose magnitude was strongly dependent on the amplitude of MEPs. Overall, these results suggest that M1 produces peculiar responses to TMS possibly reflecting specific anatomo-functional properties, such as the re-entry of proprioceptive feedback associated with target muscle activation.

neuroscience↗