Impedance-Derived Heart Rate and Heart Rate Variability from tDCS Output Voltage: Sensorless Physiological Monitoring During Electrical Neuromodulation

BackgroundTranscranial direct current stimulation (tDCS) devices adjust output voltage to maintain the target current despite varying impedance. Pulsatile blood flow produces beat-synchronous changes in tissue impedance. ObjectiveTo determine whether impedance-derived heart rate (IHR), heart rate variability (IHRV), and respiration (IDR) can be estimated from tDCS output voltage without additional physiological sensors. MethodsA custom analog front-end acquires the tDCS output voltage across its full dynamic DC range and superimposed AC fluctuations with high precision. Beats detected from the AC-coupled signal yielded normal-to-normal intervals for HR, HRV, and interval-derived respiration. Accuracy was quantified as mean absolute error (MAE) in 10 healthy laboratory participants against ECG and respiration-monitor references, and against chest-strap RR intervals in 19 at-home sessions from 10 participants with mild-to-moderate depression. ResultsLaboratory MAEs versus ECG were 0.57 bpm for HR, 9.40 ms for SDNN, and 18.90 ms for RMSSD (r = 0.995, 0.859, and 0.778; N = 10); respiratory-rate MAE was 1.36 breaths/min (r = 0.852; N = 6). Across 1-5 mA of tDCS, the cardiac voltage {Delta}Vcardiac(t) amplitude scaled linearly with current (slope, 0.073 mV/mA; p < 0.001). The pulsatile impedance {Delta}Zcardiac(t) = ({Delta}Vcardiac(t)/Iapplied) amplitude averaged 0.080 {+/-} 0.029 {Omega} (mean {+/-} SD) across 50 participant-current observations, with no significant dependence on intensity (slope, -0.002 {Omega}/mA; p = 0.086). At-home MAEs were 1.43 bpm for HR, 8.86 ms for SDNN, and 24.92 ms for RMSSD (r = 0.995, 0.767, and 0.680; 19 sessions). ConclusionstDCS output voltage contains a recoverable cardiac-synchronous signal arising from pulsatile impedance, enabling HR, HRV, and respiratory monitoring without additional physiological sensors.

bioengineering↗

Self-powered electronics-free Wearable Disposable Electrotherapy (WDE) platform for accelerated wound healing

Electrical stimulation accelerates wound repair by modulating endogenous bioelectric signals that regulate inflammation, angiogenesis, extracellular matrix remodeling, and cellular responses within the wound microenvironment. However, clinical translation has been hindered by cumbersome devices with procedures that disrupt standard wound-care workflows, direct electrode contact with the wound bed, and/or limited stimulation output. Wearable Disposable Electrotherapy (WDE) integrates an electronics-free printed electrochemical architecture into an mm-thick patch that looks and is applied like a conventional bandage. The device is self- powered and delivers a single electrotherapy dose simply by application to the skin. Device dose-control (electrochemical performance) and efficacy were evaluated in a full-thickness excisional wound model in rats, compared with a sham device and a conventional Constant Current (CC) stimulator. WDE or control treatments were applied daily from day 1 through day 13, with endpoint evaluation on day 14. WDE delivered electrical stimulation comparable to CC while reducing the time required to achieve 50% wound closure by 2.08 days ([~]29%) relative to sham treatment. Histological and immunofluorescence analyses at day 14 demonstrated enhanced tissue remodeling, including increased collagen deposition ([~]25%), tissue cellularity ([~]73%), myofibroblast-associated SMA expression ([~]2.6-fold), angiogenesis-associated CD31 expression ([~]2.0-fold), and increased expression of both M2- (CD206, [~]2.0-fold) and M1- associated (iNOS, [~]1.7-fold) markers compared with sham. A novel cellular-resolution dosimetry model, leveraging charge-based boundary element method accelerated with the fast multipole method (BEM-FMM), provides a biophysical framework linking electrical stimulation with wound microenvironment and tissue repair mechanisms. Together, these findings establish WDE as a practical bioelectric wound dressing that accelerates wound healing and tissue remodeling, with the simplicity and scalability of disposable bandages.

bioengineering↗

High-Capacity transcranial Direct Current Stimulation (HC-tDCS)

BackgroundEnhancing tDCS technology can support the delivery of higher current intensities, enabling broader dose-response studies in human trials. MethodsHigh-Capacity tDCS (HC-tDCS) integrates novel electrodes and adaptive current/voltage controlled electronics. Multi-layer HC electrodes include polarity-specific redox layers and designed hydrogel interfaces, shaped for a bifrontotemporal montage. The stimulator design includes adaptive ramps with hybrid voltage-current control and low (7.5 V) compliance voltage. Scanning electron microscopy (SEM) and electrical impedance spectroscopy (EIS) were used to characterize electrode properties. Tolerability of HD-tDCS was tested for target currents 1-6 mA (in 1 mA increments) for 30 min on 5 healthy subjects, and compared with conventional tDCS using 2 mA F3-F4 sponge-electrodes. MRI-derived computational models predicted cortical electric fields. Tolerability was assessed according to the 100 mm visual analogue scale for pain (VASP-100), skin erythema assessment, thermal imaging, and adverse event questionnaires. ResultsThe electrode design including high-roughness polarity-specific capacity, electrochemically supports high-charge direct current stimulation. In all subjects, HC-tDCS was well tolerated at all tested doses (1-6 mA) with minor transient adverse events and average VASP-100 less than 15. VASP-100 during sponge-electrode tDCS at 2 mA was comparable to 5 and 6 mA HC-tDCS. HC-tDCS operates at significantly lower voltage than sponge-tDCS, impacting tolerability and efficiency. Modeling predicts peak frontal electric fields of 0.65-1.08 V/m for 2 mA HC-tDCS and 1.95-3.25 V/m for 6 mA HC-tDCS, compared to 0.49-0.95 V/m for 2 mA sponge-tDCS. ConclusionsHC-tDCS allows increased cortical stimulation; at 6 mA achieving double the 1 V/m electric field threshold in all subjects. Enabled by pre-stimulation procedures, specialized electrodes, and adaptive low-voltage stimulators, HC-tDCS is well tolerated at intensities up to at least 6 mA.

bioengineering↗

Repeated tDCS at clinically-relevant field intensity can boost concurrent motor learning in rats.

Electric fields used in clinical trials with transcranial direct current stimulation (tDCS) are small, with magnitudes that have yet to demonstrate measurable effects in preclinical animal models. We hypothesized that weak stimulation will nevertheless produce sizable effects, provided that it is applied concurrently with behavioral training, and repeated over multiple sessions. We tested this here in a rodent model of dexterous motor-skill learning. We developed a preparation that allows concurrent stimulation during the performance of a pellet-reaching task in freely behaving rats. The task was automated to minimize experimenter bias. We measured field magnitudes intracranially to calibrate the stimulation current. In this study, only male rats were used. Animals were trained for 20 min with concurrent epicranial tDCS over 10 daily sessions. Behavior was recorded with high-speed video to quantify reaching dynamics. We also measured motor-evoked potentials (MEPs) bilaterally with epidural microstimulation. The new electrode montage enabled stable stimulation over 10 sessions with a field intensity of 2V/m at the motor cortex. The number of successful reaches improved across days of training, and the rate of learning was higher in the anodal group as compared to sham-control animals (F(1)=7.12, p=0.008, N=24). MEPs were not systematically affected by tDCS. Posthoc analysis suggests that tDCS modulated motor learning only for right-pawed animals, improving success of reaching, but limiting stereotypy in these animals. Repeated and concurrent anodal tDCS can boost motor-skill learning at clinically-relevant field intensities. In this animal model the effect interacted with paw preference and was not associated with corticospinal excitability. Significance StatementThe effects of tDCS have been explored in numerous human clinical trials, but the mechanisms of action of weak electric fields remain unclear. In vitro studies show that constant electric fields at 2.5 V/m can enhance the efficacy of synapses undergoing plasticity. This study demonstrates in a rodent model that tDCS of only 2 Vm when applied concurrently to behavioral training can improve motor skill learning, and reduce stereotypy of reaching behavior. These effects accumulated over 10 days of training. Motor evoked potentials (MEP), which are often used to demonstrate plastic effects in humans on a time scale of hours, were not measurably affected by tDCS on this longer time scale.

animal behavior and cognition↗

Wearable Disposable Electrotherapy

We design and validate a novel electrotherapy platform without electronic components, using printed abundant, environmentally benign materials. Whereas existing electrotherapy devices use an independent power source and electronics to generate and control stimulation currents, our design eliminates the need for these components. Device production relies only on scalable additive manufacturing and common materials, minimizing cost and environmental impact. The disposable single-use platform (as discreet as adhesive bandages) is activated simply by placement on the body. A prescribed electrotherapy discharge is regulated by a flexible 3D electrochemical architecture tailored to each application by a novel operational theory. The single-dose usability of this platform is a categorical shift from existing approaches with durable equipment that require programming and assembly to disposable electrodes for each use. Our Wearable Disposable Electrotherapy technology can be distributed like pharmacotherapy, with indications spanning neuromodulation of brain disorders, wound healing, transcutaneous drug delivery, bioelectronic medicine, and aesthetics.

bioengineering↗

Novel Evoked Synaptic Activity Potentials (ESAPs) elicited by Spinal Cord Stimulation

Spinal cord stimulation (SCS) evokes fast epidural Evoked Compound Action Potential (ECAPs) that represent activity of dorsal column axons, but not necessarily a spinal circuit response. Using a multimodal approach, we identified and characterized a delayed and slower potential evoked by SCS that reflects synaptic activity within the spinal cord. Anesthetized female Sprague Dawley rats were implanted with an epidural SCS lead, epidural motor cortex stimulation electrodes, an epidural spinal cord recoding lead, an intraspinal penetrating recording electrode array, and intramuscular electromyography (EMG) electrodes in the hindlimb and back. We stimulated the motor cortex or the epidural spinal cord and recorded epidural, intraspinal, and EMG responses. SCS pulses produced characteristic propagating ECAPs (composed of P1, N1, and P2 waves with latencies <2 ms) and an additional wave ("S1") starting after the N2. We verified the S1-wave was not a stimulation artifact and was not a reflection of hindlimb/back EMG. The S1-wave has a distinct stimulation-intensity dose response and spatial profile compared to ECAPs. CNQX (a selective competitive antagonist of AMPA receptors) significantly diminished the S1-wave, but not ECAPs. Furthermore, cortical stimulation, which did not evoke ECAPs, produced epidurally detectable and CNQX-sensitive responses at the same spinal sites, confirming epidural recording of an evoked synaptic response. Finally, applying 50 Hz SCS resulted in dampening of ESAPs, but not ECAPs. Therefore, we hypothesize that the S1-wave is synaptic in origin, and we term the S1-wave type responses: Evoked Synaptic Activity Potentials (ESAPs). The identification and characterization of epidurally recorded ESAPs from the dorsal horn may elucidate SCS mechanisms. Significance StatementSpinal cord stimulation (SCS) is an established treatment for chronic pain and has applications to other disorders and neurorehabilitation. Notwithstanding decades of trials and research, questions remain about SCS mechanisms of action - and indicators thereof. Recent technological developments have enabled the detection of Evoked Compound Action Potential (ECAPs) - reflecting synchronous activity of the dorsal column axons activated by SCS. However, ECAP is not a direct measure of sensory processing in the dorsal horn. Here, we identify and characterize a novel electrophysiological signal that is evoked and detectable by epidural SCS electrodes and reflects spinal synaptic currents. This new signal, termed an Evoked Synaptic Activity Potential (ESAP), is thus a novel means with which to interrogate spinal gray matter circuits during SCS.