Imaging large fields-of-view at high resolution in cryo-ET with square beam montaging

Visualizing macromolecules within their native cellular context by cryo-electron tomography (cryo-ET) is fundamentally limited by the trade-off between field of view and resolution: Capturing high-resolution information about biomolecules requires high magnification, which restricts the field of view and obscures the cellular context in which those biomolecules function. Collecting montage data by tiling the electron beam over the region of interest offers one solution, although traditional round electron beams cause excessive radiation damage across overlapping regions. We previously made electron beams square in shape, enabling montage collection with minimal overlap and thereby reducing excessive exposure and loss of high-resolution information. Here, we create a pipeline for collecting and processing montage cryo-ET data with square electron beams. We show that square beam montages retain high-resolution information by reconstructing virus-like particles to 3.5 [A] resolution using sub-tomogram averaging, and apply the workflow to imaging a glial cell and malaria parasite lamellae over fields of view up to 65 m2. We also provide a comprehensive protocol to make square beams accessible to the community.

molecular biology↗

Interleaved multi-magnification cryo-electron tomography bridges cellular and structural biology

Cryo-electron tomography (cryo-ET) enables in situ structural analysis of macromolecular complexes within native cellular environments. However, the limited field of view required for high-resolution structure determination necessarily restricts a wider assessment of the broader cellular context. We present a multi-magnification cryo-ET acquisition strategy that integrates low- and high-magnification information from coincident sample regions during the same tilt-series. By interleaving acquisition of the magnifications at each tilt angle, this strategy enables simultaneous collection of large field-of-view, low-resolution tomograms and high-resolution, small field-of-view tomograms while minimising the impact of the increased electron dose. We demonstrate that we can capture cellular organisation across tens of microns, while still enabling subtomogram averaging to resolutions below 4 [A]. This integrated acquisition framework establishes a practical route to multi-scale cryo-ET, bridging molecular and cellular scales for more comprehensive biological insight.

biochemistry↗

Atomic resolution cryo-EM at 200 keV

Atomic resolution in cryo-electron microscopy was first demonstrated six years ago. This was accomplished using 300 kV electron microscopes equipped with new hardware that provided narrower energy spread, aberration correction, and energy filtering. Here, we report the achievement of 1.24 [A] atomic resolution on an upgraded 200 kV electron microscope featuring a cold field emission gun, a high-resolution objective lens polepiece, and an energy filter. These components transform the instrument into a cost-effective single particle cryo-EM platform with performance comparable to that of significantly more expensive 300 kV systems. The microscope can also be operated at 100 kV and by using a high-speed hybrid-pixel detector we were able to reach sub-2 [A] resolution.

molecular biology↗

Smart Parallel Automated Cryo Electron tomography

In situ cryo electron tomography enables investigation of macromolecules in their native cellular environment. Data collection, however, requires an experienced operator and valuable microscope time to carefully select targets for tilt series acquisition. Here, we developed a workflow using machine learning approaches to fully automate the entire process, including lamella detection, biological feature segmentation, target selection, and tilt series acquisition, all without the need for human intervention.

biophysics↗

Parallel cryo electron tomography on in situ lamellae

In situ cryo electron tomography of cryo focused ion beam milled samples emerged in recent years as a powerful technique for structural studies of macromolecular complexes in their native cellular environment. The lamella-shaped samples, however, have a limited area and are created with a necessary pretilt. This severely limits the possibilities for recording tomographic tilt series in a high-throughput manner. Here, we utilise a geometrical sample model and optical image shift to record tens of tilt series in parallel, thereby saving time and gaining sample areas conventionally used for tracking of specimen movement. The parallel cryo electron tomography (PACE-tomo) method achieves a throughput faster than 5 min per tilt series and allows the collection of sample areas that were previously unreachable, thus maximising the amount of data from each lamella. Performance testing with ribosomes in vitro and in situ on state-of-the-art and general-purpose microscopes demonstrated the high-throughput and high-quality of PACE-tomo.

biophysics↗

Bacterial Phage Tail-like Structure Kills Eukaryotic Cells by Injecting a Nuclease Effector

Many bacteria interact with target organisms using syringe-like structures called Contractile Injection Systems (CIS). CIS structurally resemble headless bacteriophages and share evolutionarily related proteins such as the tail tube, sheath, and baseplate complex. Recent evidence shows that CIS are specialized to puncture membranes and often deliver effectors to target cells. In many cases, CIS mediate trans-kingdom interactions between bacteria and eukaryotes, however the effectors delivered to target cells and their mode of action are often unknown. In this work, we establish an in vitro model to study a CIS called Metamorphosis Associated Contractile structures (MACs) that target eukaryotic cells. We show that MACs kill two eukaryotic cell lines, Fall Armyworm Sf9 cells and J774A.1 murine macrophage cells through the action of a newly identified MAC effector, termed Pne1. To our knowledge, Pne1 is the first CIS effector exhibiting nuclease activity against eukaryotic cells. Our results define a new mechanism of CIS-mediated bacteria-eukaryote interaction and are a first step toward understanding structures with the potential to be developed as novel delivery systems for eukaryotic hosts.

microbiology↗