bioRxiv ScienceSearch

Biology subjects

Egan, G. F.

Publications and source records attributed to Egan, G. F..

3 recordsLinked to original sources

MR-PET head motion correction based on co-registration of multi-contrast MR images

Head motion is a major source of image artefacts in neuroimaging studies and can lead to degradation of the quantitative accuracy of reconstructed PET images. Simultaneous Magnetic Resonance-Positron Emission Tomography (MR-PET) makes it possible to estimate head motion information from high-resolution MR images and then correct motion artefacts in PET images. In this paper, we introduce a fully automated PET motion correction method, MR-guided MAF, based on the co-registration of multi-contrast MR images. The performance of the MR-guided MAF method was evaluated using MR-PET data acquired from a cohort of ten healthy participants who received a slow infusion of fluorodeoxyglucose ([18-F]FDG). Compared with conventional methods, MR guided PET image reconstruction can reduce head motion introduced artefacts and improve the image sharpness and quantitative accuracy of PET images acquired using simultaneous MR-PET scanners. The fully automated motion estimation method has been implemented as a publicly available web-service.

bioinformatics

Simultaneous task-based BOLD-fMRI and FDG functional PET for measurement of neuronal metabolism in the human visual cortex

Studies of task-evoked brain activity are the cornerstone of cognitive neuroscience, and unravel the spatial and temporal brain dynamics of cognition in health and disease. Blood oxygenation level dependent functional magnetic resonance imaging (BOLD-fMRI) is one of the most common methods of studying brain function in humans. BOLD-fMRI indirectly infers neuronal activity from regional changes in blood oxygenation and is not a quantitative metric of brain function. Regional variation in glucose metabolism, measured using [18-F] fluorodeoxyglucose positron emission tomography (FDG-PET), provides a more direct and interpretable measure of neuronal activity. However, while the temporal resolution of BOLD-fMRI is in the order of seconds, standard FDG-PET protocols provide a static snapshot of glucose metabolism. Here, we develop a novel experimental design for measurement of task-evoked changes in regional blood oxygenation and glucose metabolism with high temporal resolution. Over a 90-min simultaneous BOLD-fMRI/FDG-PET scan, [18F] FDG was constantly infused to 10 healthy volunteers, who viewed a flickering checkerboard presented in a hierarchical block design. Dynamic task-related changes in blood oxygenation and glucose metabolism were examined with temporal resolution of 2.5sec and 1-min, respectively. Task-related, temporally coherent brain networks of haemodynamic and metabolic connectivity were maximally related in the visual cortex, as expected. Results demonstrate that the hierarchical block design, together with the infusion FDG-PET technique, enabled both modalities to track task-related neural responses with high temporal resolution. The simultaneous MR-PET approach has the potential to provide unique insights into the dynamic haemodynamic and metabolic interactions that underlie cognition in health and disease.

neuroscience

Combining images and anatomical knowledge to improve automated vein segmentation in MRI

PurposeTo improve the accuracy of automated vein segmentation by combining susceptibility-weighted images (SWI), quantitative susceptibility maps (QSM), and a vein atlas to produce a resultant image called a composite vein image (CV image).\n\nMethodAn atlas was constructed in common space from 1072 manually traced 2D-slices. The composite vein image was derived for each subject as a weighted sum of three inputs; a SWI image, a QSM image and the vein atlas. The weights for each input and each anatomical location, called template priors, were derived by assessing the accuracy of each input over an independent data set. The accuracy of venograms derived automatically from each of the CV image, SWI, and QSM image sets was assessed by comparison with manual tracings. Three different automated vein segmentation techniques were used, and ten performance metrics evaluated.\n\nResultsVein segmentations using the CV image were comprehensively better than those derived from SWI or QSM images (mean Cohens d = 1.1). Sixty permutations of performance metric and automated segmentation technique were evaluated. Vein identification improvements that were both large and significant (Cohens d>0.80, p<0.05) were found in 77% of the permutations, compared to no improvement in 5%.\n\nConclusionThe accuracy of automated venograms derived from the composite vein image was overwhelmingly superior to venograms derived from SWI or QSM alone.

neuroscience