bioRxiv Science⌕ Search

Biology subjects

Dodds, J. N.

Publications and source records attributed to Dodds, J. N..

7 recordsLinked to original sources

Using XCiMS to Quantify the Benefits of Ion Mobility Spectrometry for Untargeted Metabolomics

Integrating ion mobility spectrometry (IMS) with liquid chromatography-mass spectrometry (LC-MS) has the potential to improve untargeted metabolomics workflows, but assessing the benefits of IMS has been challenging due to a paucity of software solutions to process raw LC-IMS-MS data in a manner that enables direct comparison with LC-MS data. We developed the XCiMS software to collapse 4D data into pseudo-3D data. Peak detection is then performed in the pseudo-3D space, followed by targeted extraction of 4D signals from 3D-guided regions of interest. Here, we applied XCiMS to estimate the potential of IMS for untargeted metabolomics when analyzing human plasma. First, we assessed the number of metabolites that are uniquely resolved by LC-IMS-MS but not LC-MS. Although as many as 50% of 3D peaks produce multiple 4D peaks when using high-resolution IMS, few represent newly resolved structural isomers. We found that the increase in features due to IMS was mostly caused by charge isomers and ion clusters. Second, we investigated the impact of IMS on metabolite identification. When using a 16-minute chromatographic separation, we found that IMS can decrease the frequency of chimeric MS/MS by about half. We conclude that while IMS adds considerable complexity to untargeted metabolomics data without resolving a large number of additional structural isomers relative to a standard LC-MS experiment, it does facilitate metabolite identification by decreasing chimeric spectra and providing CCS values for library searching.

bioinformatics↗

Unlocking the Bile Acid Universe: Advanced Workflows and a Multidimensional Library of 280 Unique Species

Microbes and bile acids are tightly intertwined, especially in the gut. While the liver produces primary bile acids from cholesterol, gut bacteria transform these into diverse secondary forms which act as powerful signaling molecules, influencing host metabolism and immune function. Since bile acid changes are increasingly linked to health and disease, their accurate measurement in the gut and circulation is essential. Analytical evaluations, however, remain challenging as many bile acids co-elute in liquid chromatography (LC), share identical precursor masses in mass spectrometry (MS), and produce similar tandem mass spectrometry (MS/MS) spectra. As a result, conventional LC-MS/MS workflows struggle to differentiate bile acids, motivating the addition of orthogonal separations such as ion mobility spectrometry (IMS). Here, we assess optimal bile acid extraction parameters for stool, serum, and plasma; compare LC conditions; and assess electrospray ionization performance across polarities. Additionally, we created a multidimensional reference library containing LC retention times, IMS collision cross section values, and accurate precursor masses for 280 unique bile acids (264 endogenous and 16 deuterium-labeled species) including unconjugated, host-conjugated, and microbially conjugated bile acids. This multidimensional library empowers bile acid identification in complex samples and enables a more comprehensive exploration of their biological roles and disease associations.

microbiology↗

Maternal PFAS Transfer through Lactation: Dolphin Milk Reveals Routes of Early-Life Exposure

Per- and polyfluoroalkyl substances (PFAS) continue to increase in concentration and prevalence in the environment due to the creation of emerging PFAS and lack of breakdown of legacy compounds. PFAS are known to both bioaccumulate and biomagnify, therefore, species higher on the food chain, such as marine mammals, are highly exposed to these chemicals. Although studies suggest that considerable maternal transfer of persistent organic pollutants occurs via lactation, data is lacking on the temporal trends associated with PFAS exposure. Here, we utilized a set of dolphin breastmilk samples from an individual mother across a two-year lactation period to evaluate longitudinal trends in PFAS concentrations and profiles. Thirty-six PFAS were detected using a multidimensional platform combining liquid chromatography, ion mobility spectrometry, and mass spectrometry (LC-IMS-MS), and of these, 17 PFAS were detected continuously across the nursing window of 103-706 days. Quantitative analysis specifically showed concentrations of perfluorooctanesulfonic acid (PFOS) alone surpass weekly intake recommendations from the European Food Safety Authority and Food Standards Australia New Zealand by 1,000-fold but decreased slightly over time, possibly due to transfer from feedings. Non-targeted analysis also identified 13 additional compounds including two long-chained perfluorosulfonic acids not traditionally targeted, as well as the PFOS precursors, perfluoroethylcyclohexane sulfonate (PFECHS) and 2-(N-ethylperfluorooctanesulfonamido)ethyl phosphate (SAmPAP). This study therefore suggests that breastmilk is a major contributor to early-life PFAS exposure to mammals, particularly for long-chained PFAS. SYNOPSISHigh concentrations of PFAS in dolphin milk reflect bioaccumulation and biomagnification, highlighting their persistence and harm to aquatic ecosystems and breastfed offspring. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=110 SRC="FIGDIR/small/651903v1_ufig1.gif" ALT="Figure 1"> View larger version (37K): org.highwire.dtl.DTLVardef@ff681eorg.highwire.dtl.DTLVardef@cbf6corg.highwire.dtl.DTLVardef@eb789dorg.highwire.dtl.DTLVardef@13ba275_HPS_FORMAT_FIGEXP M_FIG C_FIG

biochemistry↗

Reference Library for Suspect Non-targeted Screening of Environmental Toxicants Using Ion Mobility Spectrometry-Mass Spectrometry

As our health is affected by the xenobiotic chemicals we are exposed to, it is important to rapidly assess these molecules both in the environment and our bodies. Targeted analytical methods coupling either gas or liquid chromatography with mass spectrometry (GC-MS or LC-MS) are commonly utilized in current exposure assessments. While these methods are accepted as the gold standard for exposure analyses, they often require multiple sample preparation steps and more than 30 minutes per sample. This throughput limitation is a critical gap for exposure assessments and has resulted in an evolving interest in using ion mobility spectrometry and MS (IMS-MS) for non-targeted studies. IMS-MS is a unique technique due to its rapid analytical capabilities (millisecond scanning) and detection of a wide range of chemicals based on unique collision cross section (CCS) and mass-to-charge (m/z) values. To increase the availability of IMS-MS information for exposure studies, here we utilized drift tube IMS-MS to evaluate 4,685 xenobiotic chemical standards from the Environmental Protection Agency Toxicity Forecaster (ToxCast) program including pesticides, industrial chemicals, pharmaceuticals, consumer products, and per- and polyfluoroalkyl substances (PFAS). In the analyses, 3,993 [M+H]+, [M+Na]+, [M-H]- and [M+]+ ion types were observed with high confidence and reproducibility ([≤]1% error intra-laboratory and [≤]2% inter-laboratory) from 2,140 unique chemicals. These values were then assembled into an openly available multidimensional database and uploaded to PubChem to enable rapid IMS-MS suspect screening for a wide range of environmental contaminants, faster response time in environmental exposure assessments, and assessments of xenobiotic-disease connections.

ecology↗

Assessing Per- and Polyfluoroalkyl Substances (PFAS) in Fish Fillet Using Non-Targeted Analyses

Per- and polyfluoroalkyl substances (PFAS) are a class of thousands of man-made chemicals that are persistent and highly stable in the environment. Fish consumption has been identified as a key route of PFAS exposure for humans. However, routine fish monitoring targets only a handful of PFAS, and non-targeted analyses have largely only evaluated fish from heavily PFAS-impacted waters. Here, we evaluated PFAS in fish fillets from recreational and drinking water sources in central North Carolina to assess whether PFAS are present in these fillets that would not be detected by conventional targeted methods. We used liquid chromatography, ion mobility spectrometry, and mass spectrometry (LC-IMS-MS) to collect full scan feature data, performed suspect screening using an in-house library of 100 PFAS for high confidence feature identification, searched for additional PFAS features using non-targeted data analyses, and quantified perfluorooctane sulfonic acid (PFOS) in the fillet samples. A total of 36 PFAS were detected in the fish fillets, including 19 that would not be detected using common targeted methods, with a minimum of 6 and a maximum of 22 in individual fish. Median fillet PFOS levels were concerningly high at 11.6 to 42.3 ppb, and no significant correlation between PFOS levels and number of PFAS per fish was observed. Future PFAS monitoring in this region should target more of these 36 PFAS, and other regions not considered heavily PFAS contaminated should consider incorporating non-targeted analyses into ongoing fish monitoring studies. SYNOPSISConcerningly high PFOS levels were detected in fish fillets from recreational and drinking water sources in central North Carolina. Of the 36 total PFAS identified, 19 would not be detected using routine targeted monitoring methods. GRAPHICAL ABSTRACT O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=109 SRC="FIGDIR/small/555938v2_ufig1.gif" ALT="Figure 1"> View larger version (30K): org.highwire.dtl.DTLVardef@b3084org.highwire.dtl.DTLVardef@9e69bborg.highwire.dtl.DTLVardef@2f9628org.highwire.dtl.DTLVardef@2b33c8_HPS_FORMAT_FIGEXP M_FIG C_FIG For use in table of contents only

pharmacology and toxicology↗

Characterizing Adeno-Associated Virus Capsids with both Denaturing and Intact Analysis Methods

Adeno-associated virus (AAV) capsids are among the leading gene delivery platforms used to treat a vast array of human diseases and conditions. AAVs exist in a variety of serotypes due to differences in viral protein (VP) sequences, with distinct serotypes targeting specific cells and tissues. As the utility of AAVs in gene therapy increases, ensuring their specific composition is imperative for correct targeting and gene delivery. From a quality control perspective, current analytical tools are limited in their selectivity for viral protein (VP) subunits due to their sequence similiaries, instrumental difficulties in assessing the large molecular weights of intact capsids, and the uncertainity in distinguishing empty and filled capsids. To address these challenges, we combine two distinct analytical workflows that assess the intact capsids and VP subunits separately. First, charge detection-mass spectrometry (CD-MS) was applied for characterization of the intact capsids and then liquid chromatography, ion mobility spectrometry, and mass spectrometry (LC-IMS-MS) separations were used for capsid denaturing measurements. This multi-method combination was applied to 3 AAV serotypes (AAV2, AAV6, and AAV8) to evaluate their intact empty and filled capsid ratios and then examine the distinct VP sequences and modifications present.

biochemistry↗

Uncovering Xenobiotics in the Dark Metabolome using Ion Mobility Spectrometry, Mass Defect Analysis and Machine Learning

The identification of xenobiotics in nontargeted metabolomic analyses is a vital step in understanding human exposure. Xenobiotic metabolism, excretion, and co-existence with other endogenous molecules however greatly complicate nontargeted studies. While mass spectrometry (MS)-based platforms are commonly used in metabolomic measurements, deconvoluting endogenous metabolites and xenobiotics is often challenged by the lack of xenobiotic parent and metabolite standards as well as the numerous isomers possible for each small molecule m/z feature. Here, we evaluate the use of ion mobility spectrometry coupled with MS (IMS-MS) and mass defect filtering in a xenobiotic structural annotation workflow to reduce large metabolomic feature lists and uncover potential xenobiotic classes and species detected in the metabolomic studies. To evaluate the workflow, xenobiotics having known high toxicities including per- and polyfluoroalkyl substances (PFAS), polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) were examined. Initially, to address the lack of available IMS collision cross section (CCS) values for per- and polyfluoroalkyl substances (PFAS), 88 PFAS standards were evaluated with IMS-MS to both develop a targeted PFAS CCS library and for use in machine learning predictions. The CCS values for biomolecules and xenobiotics were then plotted versus m/z, clearly distinguishing the biomolecules and halogenated xenobiotics. The xenobiotic structural annotation workflow was then used to annotate potential PFAS features in NIST human serum. The workflow reduced the 2,423 detected LC-IMS-MS features to 80 possible PFAS with 17 confidently identified through targeted analyses and 48 additional features correlating with possible CompTox entries.

biochemistry↗