bioRxiv Science⌕ Search

Biology subjects

Darwish, A.

Publications and source records attributed to Darwish, A..

3 recordsLinked to original sources

Computational modeling of left ventricular flow using PC-CMR-derived four-dimensional wall motion

Intracardiac hemodynamics plays a crucial role in the onset and development of cardiac and valvular diseases. Simulations of blood flow in the left ventricle (LV) have provided valuable insight into assessing LV hemodynamics. While fully coupled fluid-solid modelings of the LV remain challenging due to the complex passive-active behavior of the LV wall myocardium, the integration of imaging-driven quantification of structural motion with computational fluid dynamics (CFD) modeling in the LV holds the promise of feasible and clinically translatable characterization of patient-specific LV hemodynamics. In this study, we propose to integrate two magnetic resonance imaging (MRI) modalities with the moving-boundary CFD method to characterize intracardiac LV hemodynamics. Our method uses the standard cine cardiac magnetic resonance (CMR) images to estimate four-dimensional myocardial motion, eliminating the need for involved myocardial material modeling to capture LV wall behavior. In conjunction with CMR, phase contrast-MRI (PC-MRI) was used to measure temporal blood inflow rates at the mitral orifice, serving as an additional boundary condition. Flow patterns, including velocity streamlines, vortex rings, and kinetic energy, were characterized and compared to the available data. Moreover, relationships between LV wall kinematic markers and flow characteristics were determined without myocardial material modeling and using a non-rigid image registration (NRIR) method. The fidelity of the simulation was quantitatively evaluated by validating the flow rate at the aortic outflow tract against respective PC-MRI measures. The proposed methodology offers a novel and feasible toolset that works with standard PC-CMR protocols to improve the clinical assessment of LV characteristics in prognostic studies and surgical planning.

bioengineering↗

Complete spatiotemporal quantification of cardiac motion in mice through enhanced acquisition and super-resolution reconstruction

The quantification of cardiac motion using cardiac magnetic resonance imaging (CMR) has shown promise as an early-stage marker for cardiovascular diseases. Despite the growing popularity of CMR-based myocardial strain calculations, measures of complete spatiotemporal strains (i.e., three-dimensional strains over the cardiac cycle) remain elusive. Complete spatiotemporal strain calculations are primarily hampered by poor spatial resolution, with the rapid motion of the cardiac wall also challenging the reproducibility of such strains. We hypothesize that a super-resolution reconstruction (SRR) framework that leverages combined image acquisitions at multiple orientations will enhance the reproducibility of complete spatiotemporal strain estimation. Two sets of CMR acquisitions were obtained for five wild-type mice, combining short-axis scans with radial and orthogonal long-axis scans. Super-resolution reconstruction, integrated with tissue classification, was performed to generate full four-dimensional (4D) images. The resulting enhanced and full 4D images enabled complete quantification of the motion in terms of 4D myocardial strains. Additionally, the effects of SRR in improving accurate strain measurements were evaluated using an in-silico heart phantom. The SRR framework revealed near isotropic spatial resolution, high structural similarity, and minimal loss of contrast, which led to overall improvements in strain accuracy. In essence, a comprehensive methodology was generated to quantify complete and reproducible myocardial deformation, aiding in the much-needed standardization of complete spatiotemporal strain calculations.

bioengineering↗

Yttrium-iron garnet film magnetometer for magnetic microparticles in vivo registration studies

In the current article, we present a new kind of magnetometer for quantitative determination of magnetic objects in biological fluids and tissues. The sensor is based on yttrium-iron garnet film with optical signal registration system. Inheriting the working principle of a fluxgate magnetometers, the sensor works at a room-temperature, its wide dynamic range allows the measurements in an unshielded environment. A small size of sensitive element combined with a short recovery time after the excitation coils are off provide us with a potentially high spatial and temporal resolution of measurements. We show the feasibility of the sensor by sensing the remanent magnetization of Magnetic Nanoparticles (MNPs) both in vitro (test tubes, dry MNPs) and in vivo (local injection of the MNPs into mice).

biophysics↗