bioRxiv Science⌕ Search

Biology subjects

Cox, J. M.

Publications and source records attributed to Cox, J. M..

6 recordsLinked to original sources

Patterned wireless transcranial optogenetics generates artificial perception

Synthesizing perceivable artificial neural inputs independent of typical sensory channels remains a fundamental challenge in the development of next-generation brain-machine interfaces. Establishing a minimally invasive, wirelessly effective, and miniaturized platform with long-term stability is crucial for creating a clinically meaningful interface capable of mediating artificial perceptual feedback. In this study, we demonstrate a miniaturized fully implantable wireless transcranial optogenetic encoder designed to generate artificial perceptions through digitized optogenetic manipulation of large cortical ensembles. This platform enables the spatiotemporal orchestration of large-scale cortical activity for remote perception genesis via real-time wireless communication and control, with optimized device performance achieved by simulation-guided methods addressing light and heat propagation during operation. Cue discrimination during operant learning demonstrates the wireless genesis of artificial percepts sensed by mice, where spatial distance across large cortical networks and sequential order-based analyses of discrimination performance reveal principles that adhere to general perceptual rules. These conceptual and technical advancements expand our understanding of artificial neural syntax and its perception by the brain, guiding the evolution of next-generation brain-machine communication.

neuroscience↗

Region-specific Nucleus Accumbens Dopamine Signals Encode Distinct Aspects of Avoidance Learning

Avoidance learning - learning to avoid bad outcomes - is an essential survival behavior. Dopamine signals are widely observed in response to aversive stimuli, indicating they could play a role in learning about how to avoid these stimuli. However, it is unclear what computations dopamine signals perform to support avoidance learning. Furthermore, substantial heterogeneity in dopamine responses to aversive stimuli has been observed across nucleus accumbens (NAc) subregions. To understand how heterogeneous dopamine responses to aversive stimuli contribute to avoidance learning, we recorded NAc core (Core) and NAc ventromedial shell (vmShell) dopamine during a task in which mice could avoid a footshock punishment by moving to the opposite side of a 2-chamber apparatus during a five-second warning cue. We found that NAc Core and vmShell dopamine signals responded oppositely during shocks and warning cues. Both signals evolved substantially - but differently - with learning. NAc vmShell dopamine responses to cues and shocks were present during early learning but not sustained during expert performance. NAc Core dopamine responses strengthen with learning and are especially evident during expert performance. Our data support a model in which NAc vmShell dopamine guides initial cue-shock associations by signaling salience, while NAc Core dopamine encodes prediction errors that guide the consolidation of avoidance learning.

neuroscience↗

Pattern of Self-Administered Vapor Fentanyl Exposure Determines Long-term Behavior Consequences, in Mice with or without Neuropathic Pain

We studied the behavioral consequences of fentanyl vapor self-administration (SA) in mice with and without chronic neuropathic pain (one month after spared-nerve injury(SNI) model or sham injury). We assessed fentanyl consumption, motivation, and seeking during as well as anxiety, hyperactivity, immobility, and pain for two regimens of fentanyl SA: 1) Dose escalation, where over a 3-week period mice are exposed (daily 2-hour sessions) to escalating numbers of fentanyl puffs per active nosepoke (from 1 puff/active nosepoke for first 3 days, up to 6 puffs/active nosepoke in days 16-18). 2) Effort escalation, where over a 3-week period (daily 2-hour sessions) mice need to increase effort to acquire the same amount of fentanyl (fixed ratio 1 (FR) = 1 active nosepoke results in 1 fentanyl puff, while second and third week we use FR5 and FR10). We observe sex-, injury- and regimen-dependent differences in outcomes. Importantly the dose escalation regimen resulted in higher seeking behavior (post forced abstinence, context and cue driven nosepoking in the absence of fentanyl delivery), long lasting increased anxiety, immobility, and hyperactivity, as well as transient but full pain relief in SNI mice. Therefore, this regimen seems a better rodent model for translating outcomes to human chronic pain patients managed with opioids.

neuroscience↗

A neural substrate of sex-dependent modulation of motivation by value

While there is emerging evidence of sex differences in decision-making behavior, the neural substrates that underlie such differences remain largely unknown. Here, we demonstrate that in mice performing a value-based decision-making task, while choices are similar between the sexes, motivation to engage in the task is modulated by action value in females more strongly than in males. Inhibition of activity in anterior cingulate cortex (ACC) neurons that project to the dorsomedial striatum (DMS) disrupts this relationship between value and motivation preferentially in females, without affecting choice in either sex. In line with these effects, in females compared to males, ACC-DMS neurons have stronger representations of negative outcomes, and more neurons are active when the value of the chosen option is low. In contrast, the representation of each choice is similar between the sexes. Thus, we identify a neural substrate that contributes to sex-specific modulation of motivation by value.

neuroscience↗

Heterogeneous Tissue Modulus Improved Prediction of Mechanical Behavior in Osteoporotic Vertebral Cancellous Bone

The structural integrity of cancellous bone, which is essential to its skeletal load-bearing capacity, is governed chiefly by apparent density, trabecular architecture, and tissue material properties. Metabolic bone disorders such as osteoporosis can affect each of these factors, resulting in compromised load-bearing function and fracture. While the impact of apparent density and architecture on bone structural behavior is well-documented, much less is known about the influence of tissue material properties, particularly in osteoporotic bone. In this work, we isolated the influence of tissue modulus on normal and osteoporotic cancellous bone structural integrity, indicated by the apparent elastic modulus under uniaxial compression and patterns of internal tissue strain. Finite element (FE) models derived from 3D micro-computed tomography images were compared to physical testing data of the same samples. Three sets of FE models with increasing material detail were studied: 1) universal tissue elastic modulus (20 GPa), 2) specimen-specific average tissue modulus, and 3) heterogeneous tissue modulus. Applying a universal modulus resulted in overestimation of osteoporotic bone apparent modulus; applying specimen-specific material properties, either as a single average tissue modulus or heterogeneous distribution of tissue moduli, prevented significant apparent modulus overestimation. The greatest improvement in apparent modulus prediction resulted from incorporating a specimen-specific average tissue modulus, though using a specimen-specific heterogeneous tissue modulus provided the most reliable prediction of apparent modulus overall. In addition, median element strain in heterogeneous models also trended lower than in homogeneous models. This finding suggests that heterogeneous material properties may play a role in protective strain-concentrating mechanisms observed in cancellous bone. We conclude that future work exploring trabecular bone mechanics through finite element analysis should incorporate specimen-specific average tissue modulus at a minimum, but heterogeneous tissue modulus is recommended to maximize the functional similarity of bone in silico with bone in vivo.

bioengineering↗

High Fat Diet-Induced Obesity Negatively Affects Whole Bone Bending Strength but not Cortical Structure in the Femur

Although body mass index is positively associated with bone mineral density, suggesting obesity is protective against fracture, elderly obese individuals experience greater fracture risk at certain sites than non-obese peers, suggesting bone structural or material changes contribute to fragility. Diet-induced obesity rodent studies have reported detrimental changes to bone microstructure and some apparent-level material properties, but tissue-level material changes are not well understood. Because adipose tissue is highly vascularized, and bone remodeling depends critically on functional vascular supply, concurrent effects on osteovascular perfusion and structure may provide insight about obesity-related bone fragility. This study aimed to determine the effects of obesity on both tissue-level bone properties and osteovascular properties that could negatively impact bone strength. Five-week-old male C57Bl/6J mice were fed either high fat diet (HFD) or control fat diet (CFD) for 17 weeks and received daily treadmill exercise or remained sedentary for eight weeks at ages 14-22 weeks. HFD negatively affected femur bending strength, with 18% lower yield load than CFD. Although HFD negatively altered cancellous microstructure in the distal femur, with 32% lower bone volume fraction than CFD, it did not affect cortical bone geometry in the femoral metaphysis or diaphysis. HFD caused increased carbonate substitution but had no effect on other composition metrics or apparent- or tissue-level material properties in the femoral diaphysis. Exercise did not affect bone strength or microstructure but increased endosteal mineralizing surface in the tibial diaphysis, mineral crystallinity and mineral-to-matrix ratio in the femur, and blood supply to the proximal tibial metaphysis. HFD did not affect blood supply in the tibia or 2D osteovascular structure in the distal femoral metaphysis, indicating that HFD negatively affects cancellous bone without affecting osteovasculature. This study reveals that HFD negatively affected cancellous microstructure without affecting osteovascular structure, and whole-bone strength without altering cortical geometry or material properties.

bioengineering↗