bioRxiv Science⌕ Search

Biology subjects

Chen, A. P.

Publications and source records attributed to Chen, A. P..

6 recordsLinked to original sources

Task Activation Results in Regional 13C-Lactate Signal Increase in the Human Brain

Hyperpolarized-13C magnetic resonance imaging (HP-13C MRI) was used to image changes in 13C-lactate signal during a visual stimulus condition in comparison to an eyes-closed control condition. Whole-brain 13C-pyruvate, 13C-lactate and 13C-bicarbonate production was imaged in healthy volunteers (N=6, ages 24-33) for the two conditions using two separate hyperpolarized 13C-pyruvate injections. BOLD-fMRI scans were used to delineate regions of functional activation. 13C-metabolite signal was normalized by 13C-metabolite signal from the brainstem and the percentage change in 13C-metabolite signal conditions was calculated. A one-way Wilcoxon signed-rank test showed a significant increase in 13C-lactate in regions of activation when compared to the remainder of the brain (p = 0.02, V = 21). No significant increase was observed in 13C-pyruvate (p = 0.11, V = 17) or 13C-bicarbonate (p = 0.95, V = 3) signal. The results show an increase in 13C-lactate production in the activated region that is measurable with HP-13C MRI.

neuroscience↗

Evidence of Lactate Shuttling in the Human Brain using Hyperpolarized 13C-MRI

PurposeTo test the hypothesis that lactate shuttling contributes to the 13C-lactate and 13C-bicarbonate signal observed in the awake human brain using hyperpolarized 13C MRI. MethodsHealthy human volunteers (n = 6) were scanned twice using hyperpolarized 13C-MRI, with reduced radiofrequency saturation of 13C-lactate on one set of scans. 13C-lactate, 13C-bicarbonate, and 13C-pyruvate signals for 132 brain regions across each set of scans were compared using a clustered Wilcoxon sum rank test. ResultsReduced 13C-lactate radiofrequency saturation resulted in a significantly greater 13C-bicarbonate signal (p = 0.04). These changes were observed across the majority of brain regions. ConclusionRadiofrequency saturation of 13C-lactate leads to a decrease in 13C-bicarbonate signal, demonstrating that the 13C-lactate generated from the injected 13C-pyruvate is being converted back to 13C-pyruvate and oxidized throughout the human brain.

neuroscience↗

Greater breadth of vaccine-induced immunity in females than males is mediated by increased antibody diversity in germinal center B cells

Inactivated influenza vaccines induce greater antibody responses in females than males among both humans and mice. To test the breadth of protection, we used recombinant mouse-adapted A/California/2009 (maA/Cal/09) H1N1 viruses containing mutations at one (1M), two (2M), or three (3M) antigenic sites, in addition to a virus containing the 1M mutation and a substitution of the Ca2 antigenic site (Sub) with one derived from an H5 hemagglutinin (HA) to challenge mice of both sexes. Following maA/Cal/09 vaccination, females produced greater virus-specific class-switched IgG and IgG2c antibodies against the vaccine and all mutant viruses, and antibodies from females recognized more unique, linear HA epitopes than antibodies from males. While females had greater neutralizing antibody (nAb) titers against the vaccine virus, both sexes showed lower neutralization capacity against mutant viruses. After virus challenge, vaccinated females had lower pulmonary virus titers and reduced morbidity than males against the 1M and 2M viruses, but not the Sub virus. Females generated greater numbers of germinal center (GC) B cells containing superior somatic hypermutation frequencies than vaccinated males. Deletion of activation-induced cytidine deaminase (Aicda) eliminated female-biased immunity and protection against the 2M virus. Harnessing methods to improve GC B cell responses and frequencies of somatic hypermutations, especially in males, should be considered in the development of universal influenza vaccines. SummaryCompared with males, inactivated influenza vaccination of female mice causes greater production of class-switched, somatically-hypermutated antibodies and a more robust germinal center B cell response, leading to more diverse H1N1 antigen recognition and better protection against mutant influenza A viruses.

immunology↗

Cardiac metabolic imaging using hyperpolarized lactate as a substrate

Hyperpolarized [1-13C]lactate is an attractive alternative to [1-13C]pyruvate as a substrate to investigate cardiac metabolism in vivo; it can be administered safely at a higher dose and can be polarized to a similar degree as pyruvate via dynamic nuclear polarization. While 13C cardiac experiments using HP lactate have been performed in small animal models, it has not been demonstrated in large animal models or humans. Utilizing the same hardware and data acquisition methods used in the first human HP 13C cardiac study, 13C metabolic images were acquired following injections of HP [1-13C]lactate in porcine hearts. Data were also acquired using HP [1-13C]pyruvate for comparison. The 13C bicarbonate signal was localized to the myocardium and had a similar appearance with both substrates for all animals. No 13C pyruvate signal was detected in the experiments following injection of hyperpolarized 13C lactate. The SNR of injected lactate was 88 +/-14% of the SNR of injected pyruvate, and the SNR of bicarbonate in the experiments using lactate as the substrate was 52+/-19% of the SNR in the experiments using pyruvate as the substrate. The lower SNR was likely due to the shorter T1 of [1-13C]lactate as compared to [1-13C]pyruvate and the additional enzyme-catalyzed metabolic conversion step before the 13C nuclei from [1-13C]lactate were detected as 13C bicarbonate. While challenges remain, the potential of HP lactate as a substrate for clinical metabolic imaging of human heart was demonstrated.

biophysics↗

Distinguishing Closely Related Pancreatic Cancer Subtypes In Vivo by 13C Glucose MRI without Hyperpolarization

Metabolic differences between patients and within the tumor itself can be an important determinant in cancer treatment outcome. However, methods for determining these differences non-invasively in vivo have been lacking. Using pancreatic ductal adenocarcinoma as a model, we demonstrate that tumor xenografts with a similar genetic background can be distinguished by their differing rates of metabolism, as detected by imaging of uniformly 13C labeled glucose tracers using a newly developed technique using tensor decomposition for noise suppression to bring the signal to a detectable level without hyperpolarization of the tracer. Using this method, cancer subtypes that appeared to exhibit similar metabolic profiles by other techniques that measured steady state metabolism can be distinguished.

cancer biology↗

PET by MRI: Glucose Imaging by 13C-MRS without Dynamic Nuclear Polarization by Noise Suppression through Tensor Decomposition Rank Reduction

Metabolic reprogramming is one of the defining features of cancer and abnormal metabolism is associated with many other pathologies. Molecular imaging techniques capable of detecting such changes have become essential for cancer diagnosis, treatment planning, and surveillance. In particular, 18F-FDG (fluorodeoxyglucose) PET has emerged as an essential imaging modality for cancer because of its unique ability to detect a disturbed molecular pathway through measurements of glucose uptake. However, FDG-PET has limitations that restrict its usefulness in certain situations and the information gained is limited to glucose uptake only. 13C magnetic resonance spectroscopy theoretically has certain advantages over FDG-PET, but its inherent low sensitivity has restricted its use mostly to single voxel measurements. We show here a new method of imaging glucose metabolism in vivo that relies on a simple, but robust and efficient, post-processing procedure by the higher dimensional analog of singular value decomposition, tensor decomposition. Using this procedure, we achieve an order of magnitude increase in signal to noise in both dDNP and non-hyperpolarized non-localized experiments without sacrificing accuracy. In CSI experiments an approximately 30-fold increase was observed, enough that the glucose to lactate conversion indicative of the Warburg effect can be imaged without hyper-polarization with a time resolution of 12 s and an overall spatial resolution that compares favorably to 18F-FDG PET.

cancer biology↗