bioRxiv ScienceSearch

Biology subjects

Charbon, E.

Publications and source records attributed to Charbon, E..

2 recordsLinked to original sources

Wide-field time-gated SPAD imager for phasor-based FLIM applications

We describe the performance of a new wide area time-gated single-photon avalanche diode (SPAD) array for phasor-FLIM, exploring the effect of gate length, gate number and signal intensity on the measured lifetime accuracy and precision. We conclude that the detector functions essentially as an ideal shot noise limited sensor and is capable of video rate FLIM measurement. The phasor approach used in this work appears ideally suited to handle the large amount of data generated by this type of very large sensor (512x512 pixels), even in the case of small number of gates and limited photon budget.

biophysics

Single Photon, Time-Gated, Phasor-based Fluorescence Lifetime Imaging Through Highly Scattering Medium

Fluorescence lifetime imaging (FLI) is a powerful tool for in vitro and non-invasive in vivo biomolecular and cellular investigations. Fluorescence lifetime is an intrinsic characteristic of any fluorescent dye which, to some extent, does not depend on excitation intensity and signal level. However, when used in vivo with visible wavelength emitting fluorophores, FLI is complicated by (i) light scattering as well as absorption by tissues, which significantly reduces fluorescence intensity, (ii) tissue autofluorescence (AF), which decreases the signal to noise ratio and (iii) broadening of the decay signal, which can result in incorrect lifetime estimation. Here, we report the use of a large-frame time-gated single-photon avalanche diode (SPAD) imager, SwissSPAD2, with a very short acquisition time (in the milliseconds range) and a wide-field microscopy format. We use the phasor approach to convert each pixels data into its local lifetime. The phasor transformation provides a simple and fast visual method for lifetime imaging and is particularly suitable for in vivo FLI which suffers from deformation of the fluorescence decay, and makes lifetime extraction by standard fitting challenging. We show, for single dyes, that the phasor cloud distribution (of pixels) increases with decay broadening due to scattering and decreasing fluorescence intensity. Yet, as long as the fluorescence signal is higher than the tissue-like phantom AF, a distinct lifetime can still be clearly identified with an appropriate background correction. Lastly, we demonstrate the detection of few hundred thousand A459 cells expressing the fluorescent protein mCyRFP1 through highly scattering phantom layers, despite significant scattering and the presence of the phantom AF.

bioengineering