bioRxiv Science⌕ Search

Biology subjects

Catreux, S.

Publications and source records attributed to Catreux, S..

5 recordsLinked to original sources

The Genome In A Bottle HG002 assembly-based variant benchmark set enables comprehensive benchmarking of small and structural variants.

High-accuracy, high-resolution benchmark data are fundamental to improving the accuracy and generalizability of sequencing technologies and associated algorithms. Most existing benchmarks for DNA sequencing rely on mapping to a single linear reference, omitting inaccessible and highly repetitive complex genomic regions. Here, we present the Genome in a Bottle (GIAB) Consortium's HG002 v5.0q benchmark set, a more comprehensive variant benchmark derived from a fully phased, highly curated, and accurate diploid assembly of HG002. Our approach leverages recent advances in long-read sequencing and assembly to provide confident small- and structural-variant calls across previously inaccessible regions, including segmental duplications, homopolymers, tandem repeats, and complex immune loci. The v5.0 benchmark significantly expands the callable genome relative to v4.2.1, adding x200 Mbp of sequence and increasing variant detection by 18 % for small variants and 3-fold for structural variants compared to previous benchmarks. The benchmark regions include more variants in repetitive regions, including 1.2 x segmental duplications, 1.8 x tandem repeats, and 2.0 x homopolymers, compared to v4.2.1. Separate and combined small- and structural-variant benchmarks are available for three versions of the human reference genome (GRCh37, GRCh38, and CHM13). We validate the reliability of this benchmark set by comparing multiple sequencing technologies and variant calling pipelines and curating differences. The v5.0q benchmark provides a critical resource for the development and validation of next-generation sequencing technologies and analysis methods.

genomics↗

A complete human pancreatic cancer genome

Cancer genome sequencing is essential for understanding tumor evolution and advancing precision medicine.1 However, reference gaps and germline variants obscure detection of small and large somatic variants and methylation in repetitive regions.1-3 It is common for tumor cells to gain or lose chromosome arms due to somatic structural changes that occur inside highly repetitive satellite DNA sequences in the centromeres.4 To identify the full spectrum of somatic variants, including complex rearrangements, we construct and curate near-complete, haplotype-resolved assemblies of the most recent common ancestor of an early-passage broadly-consented hypodiploid pancreatic cancer cell line and matched normal tissues. The tumor assembly completely recapitulates all 35 tumor chromosomes observed with karyotyping, with multiple translocation-induced hybrid chromosomes. The hybrid chromosomes contain putative functional dicentric and fused centromeres, nested foldback inversions causing 14 breakpoints with a haplotype switch in a single event, and centromeric satellite tandem duplications up to 136 kbp. Direct comparison of tumor and normal assembly haplotypes uncovers >7,000 variants altering >1 Mbp of sequence in repetitive regions that have been hidden by reference gaps and germline variants. 44 % of somatic small variants change representation because they alter germline variants on GRCh38, impacting mutational signatures and kataegis/omikli clusters. Most somatic LINE insertions originate from two hypomethylated non-reference germline LINE insertions, highlighting their impact on insertion mutation burden. These assemblies demonstrate that centromeric, acrocentric, and telomeric regions conventionally excluded from analysis harbor extensive somatic and epigenetic changes. Resolving complete tumor genomes enables a deeper understanding of cancer structural plasticity and the endpoints of breakage-fusion-bridge cycles. These assembled, curated paired normal-tumor benchmarks will serve as a critical foundation for developing future algorithms to characterize the most intractable regions of cancer genomes.

genomics↗

A robust benchmark for detecting low-frequency variants in the HG002 Genome In A Bottle NIST reference material.

Somatic mosaicism is an important cause of disease, but mosaic and somatic variants are often challenging to detect because they exist in only a fraction of cells. To address the need for benchmarking subclonal variants in normal cell populations, we developed a benchmark containing mosaic variants in the Genome in a Bottle Consortium (GIAB) HG002 reference material DNA from a large batch of a normal lymphoblastoid cell line. First, we used a somatic variant caller with high coverage (300x) Illumina whole genome sequencing data from the Ashkenazi Jewish trio to detect variants in HG002 not detected in at least 5% of cells from the combined parental data. These candidate mosaic variants were subsequently evaluated using >100x BGI, Element, and PacBio HiFi data. High confidence candidate SNVs with variant allele fractions above 5% were included in the HG002 draft mosaic variant benchmark, with 13/85 occurring in medically relevant gene regions. We also delineated a 2.45 Gbp subset of the previously defined germline autosomal benchmark regions for HG002 in which no additional mosaic variants >2% exist, enabling robust assessment of false positives. The variant allele fraction of some mosaic variants is different between batches of cells, so using data from the homogeneous batch of reference material DNA is critical for benchmarking these variants. External validation of this mosaic benchmark showed it can be used to reliably identify both false negatives and false positives for a variety of technologies and detection algorithms, demonstrating its utility for optimization and validation. By adding our characterization of mosaic variants in this widely-used cell line, we support extensive benchmarking efforts using it in simulation, spike-in, and mixture studies.

bioinformatics↗

Comprehensive and accurate genome analysis at scale using DRAGEN accelerated algorithms

Research and medical genomics require comprehensive and scalable solutions to drive the discovery of novel disease targets, evolutionary drivers, and genetic markers with clinical significance. This necessitates a framework to identify all types of variants independent of their size (e.g., SNV/SV) or location (e.g., repeats). Here we present DRAGEN that utilizes novel methods based on multigenomes, hardware acceleration, and machine learning based variant detection to provide novel insights into individual genomes with [~]30min computation time (from raw reads to variant detection). DRAGEN outperforms all other state-of-the-art methods in speed and accuracy across all variant types (SNV, indel, STR, SV, CNV) and further incorporates specialized methods to obtain key insights in medically relevant genes (e.g., HLA, SMN, GBA). We showcase DRAGEN across 3,202 genomes and demonstrate its scalability, accuracy, and innovations to further advance the integration of comprehensive genomics for research and medical applications.

genomics↗

Somatic small-variant calling methods in Illumina DRAGEN™ Secondary Analysis

We present the DRAGEN somatic pipeline for calling small somatic variants from tumor samples, with or without paired normal samples. The DRAGEN somatic variant caller offers 1) a flexible architecture that can be used on a wide array of somatic use cases; 2) built-in noise models enabling robustness against various sources of noise artifacts (mapping, genome context, or sample specific); 3) performance of joint analysis of tumor and normal samples in the case of a tumor-normal workflow yielding improved accuracy; 4) benefits from FPGA acceleration for efficient run time. We demonstrate the speed and accuracy of the DRAGEN tumor-normal pipeline across a range of whole genome sequencing (WGS) datasets and compare against third party tools such as Mutect2/GATK4 [1] and Strelka2 [2]. DRAGEN secondary analysis outperforms all other tools with its ability to complete a 110x/40x T/N whole-genome analysis in less than two hours. It offers exceptional accuracy, with higher sensitivity and precision than third party tools. We also show that the DRAGEN T/N workflow supports analysis of liquid and late-stage solid tumors by tolerating tumor-in-normal (TiN) contamination.

bioinformatics↗