bioRxiv Science⌕ Search

Biology subjects

Castello, M.

Publications and source records attributed to Castello, M..

7 recordsLinked to original sources

Unveiling the Emotional Turmoil: How Covid-19 impacted researchers and the pursuit of emotional well-being in academia.

The Covid-19 crisis unprecedentedly required researchers to adapt to significant changes in their work and personal lives. Our study aims to fill this gap analysing the Covid-19 emotional impact and confinement potential disruptions on researchers activity (specifically, those related to working conditions, caring responsibilities, health, balance, and social support) considering the modulating role played by age, gender, and job position. An online survey was distributed during the first lockdown period of the Covid-19 pandemic, and answers from 1301 researchers (ECR %, senior researchers %) working in Sciences (28.1%), Social Sciences (25.9%), Humanities (16.2%), Health (16.2%) and in Engineering and Architecture (13.5%) were collected. The study highlights that the initial lockdown during the Covid-19 pandemic had a significant emotional impact on researchers, exacerbating pre-existing emotional distress and burnout within this group. Factors such as age, health, gender, and difficulties in balancing work and family life were associated with an increased risk of burnout and emotional distress. Lack of social support was identified as a significant risk factor, while the academic culture prioritizing productivity over well-being contributed to the issue. These findings underscore the need for greater support and cultural changes in academia to preserve researchers mental health and prevent the chronicization of mental health issues in young academics.

scientific communication and education↗

A Compact and Effective Photon-Resolved Image Scanning Microscope

Fluorescence confocal laser-scanning microscopy (LSM) is one of the most popular tools for life science research. This popularity is expected to grow thanks to single-photon array detectors tailored for LSM. These detectors offer unique single-photon spatiotemporal information, opening new perspectives for gentle and quantitative super-resolution imaging. However, a flawless recording of this information poses significant challenges for the microscope data-acquisition system. Here, we present a data-acquisition module based on the digital frequency domain principle, able to record photons essential spatial and temporal features. We use this module to extend the capabilities of established imaging techniques based on single-photon avalanche diode (SPAD) array detectors, such as fluorescence lifetime image scanning microscopy. Furthermore, we use the module to introduce a robust multi-species approach encoding the fluorophores excitation spectra in the time domain. Lastly, we combine time-resolved stimulated emission depletion microscopy with image scanning microscopy, boosting spatial resolution. Our results demonstrate how a conventional fluorescence laser scanning microscope can transform into a simple, information-rich, super-resolved imaging system with the simple addition of a SPAD array detector with a tailored data acquisition system. We expected a blooming of advanced single-photon imaging techniques which effectively harness all the sample information encoded in each photon.

biophysics↗

Focus-ISM for Sharp and Gentle Super-Resolved Microscopy

Super-resolution microscopy is routinely used for fixed and thin samples, while its feasibility for imaging live and thick samples is still limited. In the case of stimulated emission depletion (STED) microscopy, the high-intensity illumination required to achieve effective sub-diffraction resolution can introduce photo-damage, thus reducing the compatibility of the technique with live-cell imaging. Moreover, the out-of-focus fluorescence background may overcome the often faint signal stemming from the focal point, thus constraining imaging to thin samples. Here, we combined STED microscopy with image-scanning microscopy (ISM) to mitigate these limitations without any practical disadvantages. We first enhanced a laser scanning microscope (LSM) by introducing a detector array, hence providing access to a set of additional spatial information that is not available with a typical single-element detector. Then, we exploited this extended dataset to implement focus-ISM, a novel method that relaxes the high-intensity requirement of STED microscopy and removes the out-of-focus background. Additionally, we generalized the focus-ISM method to conventional LSM, namely without a STED beam. The proposed approach requires minimal architectural changes compared with conventional STED microscopes but provides substantial advantages for live and thick sample imaging while maintaining all compatibility with all recent advances in STED and confocal microscopy. As such, focus-ISM represents an essential step towards a universal super-resolved LSM technique for subcellular imaging.

biophysics↗

Synergic Combination of Stimulated Emission Depletion Microscopy with Image Scanning Microscopy to Reduce Light Dosage

Stimulated emission depletion (STED) microscopy is one of the most influential nanoscopy techniques; by increasing the STED beam intensity, it theoretically improves the spatial resolution to any desired value. However, the higher is the dose of stimulating photons, the stronger are the photo-bleaching and photo-toxicity effects, which potentially compromise live-cell and long-term imaging. For this reason the scientific community is looking for strategies to reduce the STED beam intensity needed to achieve a target resolution. Here, we show how the combination of STED microscopy with image scanning microscopy (ISM) meets this request. In particular, we introduce a new STED-ISM architecture - based on our recent single-photon-avalanche-diode (SPAD) detector array - which allows covering the near-diffraction limit resolution range with reduced STED beam intensity. We demonstrate this ability both with simulated data and in live-cell experiments. Because of (i) the minimal changes in the optical architecture of the typical point-scanning STED microscope; (ii) the parameter-free, robust and real-time pixel-reassignment method to obtain the STED-ISM image; (iii) the compatibility with all the recent progresses in STED microscopy, we envisage a natural and rapid upgrade of any STED microscope to the proposed STED-ISM architecture.

bioengineering↗

Easy Two-Photon Image Scanning Microscopy with SPAD Array and Blind Image Reconstruction

Two-photon excitation (2PE) microscopy is the imaging modality of choice, when one desires to work with thick biological samples, possibly in-vivo. However, the resolution in two-photon microscopy is poor, below confocal microscopy, and the lack of an optical pinhole becomes apparent in complex samples as reduced quality of optical sectioning. Here, we propose a straightforward implementation of 2PE image scanning microscopy (2PE-ISM) that, by leveraging our recently introduced ISM platform - based on a new single-photon avalanche diode array detector - coupled with a novel blind image reconstruction method, is shown to improve the optical resolution, as well as the overall image quality in various test samples. Most importantly, our 2PE-ISM implementation requires no calibration or other input from the user - it works like any old and familiar two-photon system, but simply produces higher resolution images (in real-time). Making the complexity disappear, in our view, is the biggest novelty here, and the key for making 2PE-ISM mainstream.

bioengineering↗

Fourier ring correlation simplifies image restoration in fluorescence microscopy

Fourier ring correlation (FRC) has recently gained some popularity among (super-resolution) fluorescence microscopists as a straightforward and objective method to measure the effective resolution of a microscopy image. While the knowledge of the numeric resolution value is helpful in e.g. interpreting imaging results, much more practical use can be made of FRC analysis - in this article we propose novel blind image restoration methods enabled by it. We apply FRC to perform image de-noising by frequency domain filtering. We propose novel blind linear and non-linear image deconvolution methods that use FRC to estimate the effective point-spread-function, directly from the images, with no need for prior knowledge of the instrument or sample characteristics. The deconvolution is shown to work exquisitely with both two- and three-dimensional images. We also show how FRC can be used as a powerful metric to observe the progress of iterative deconvolution. While developing the image restoration methods, we also addressed two important limitations in FRC that are of more general interest: how to make FRC work with single images and with three-dimensional images with anisotropic resolution.

bioinformatics↗

Image Scanning Microscopy with Single-Photon Detector Array

Image scanning microscopy (ISM) improves the spatial resolution of conventional confocal laser-scanning microscopy (CLSM), but current implementations reduce versatility and restrict its combination with fluorescence spectroscopy techniques, such as fluorescence lifetime. Here, we describe a natural design of ISM based on a fast single-photon detector array, which allows straightforward upgrade of an existing confocal microscope, without compromising any of its functionalities. In contrast to all-optical ISM implementations, our approach provides access to the raw scanned images, opening the way to adaptive reconstruction methods, capable of considering different imaging conditions and distortions. We demonstrate its utility in the context of fluorescence lifetime, deep, multicolor and live-cell imaging. This implementation will pave the way for a transparent and massive transition from conventional CLSM to ISM.\n\nconfocal microscopy | time-resolved spectroscopy | image scanning microscopy | single-photon detector array

bioengineering↗