Validation of a Microfluidic Device Prototype for Cancer Detection and Identification: Circulating Tumor Cells Classification Based on Cell Trajectory Analysis Leveraging Cell-Based Modeling and Machine Learning

Microfluidic devices (MDs) present a novel method for detecting circulating tumor cells (CTCs), enhancing the process through targeted techniques and visual inspection. However, current approaches often yield heterogeneous CTC populations, necessitating additional processing for comprehensive analysis and phenotype identification. These procedures are often expensive, time-consuming, and need to be performed by skilled technicians. In this study, we investigate the potential of a cost-effective and efficient hyperuniform micropost MD approach for CTC classification. Our approach combines mathematical modeling of fluid-structure interactions in a simulated microfluidic channel with machine learning techniques. Specifically, we developed a cell-based modeling framework to assess CTC dynamics in erythrocyte-laden plasma flow, generating a large dataset of CTC trajectories that account for two distinct CTC phenotypes. Convolutional Neural Network (CNN) and Recurrent Neural Network (RNN) were then employed to analyze the dataset and classify these phenotypes. The results demonstrate the potential effectiveness of the hyperuniform micropost MD design and analysis approach in distinguishing between different CTC phenotypes based on cell trajectory, offering a promising avenue for early cancer detection. Author summaryEarly detection is currently the most effective method to combat cancer, as it maximizes treatment options and improves potential survival rates. However, the cost of early detection presents a significant barrier, limiting access for underrepresented groups and discouraging industrial partners from investing in the research and development of screening devices. This study provides an in-silico conceptual validation for the development of an innovative hyperuniform microchip designed to identify circulating tumor cells (CTCs) without the need for biomarker labeling. We created a cell-based modeling framework to examine CTC dynamics in erythrocyte-laden plasma flow, producing an extensive dataset of CTC trajectories that reflect two distinct CTC phenotypes. Two machine learning architectures were utilized to analyze this dataset and classify the phenotypes. The results demonstrate the potential effectiveness of the hyperuniform micropost MD design and analysis approach in distinguishing between different CTC phenotypes based on cell trajectory, offering a promising and cost-effective method for early cancer detection.

cancer biology↗

A Computational Algorithm for Optimal Design of Bioartificial Organ Scaffold Architectures

We develop a computational algorithm based on a diffuse interface approach to study the design of bioartificial organ scaffold architectures. These scaffolds, composed of poroelastic hydrogels housing transplanted cells, are linked to the patients blood circulation via an anastomosis graft. Before entering the scaffold, the blood flow passes through a filter, and the resulting filtered blood plasma transports oxygen and nutrients to sustain the viability of transplanted cells over the long term. A key issue in maintaining cell viability is the design of ultrafiltrate channels within the hydrogel scaffold to facilitate advection-enhanced oxygen supply ensuring oxygen levels remain above a critical threshold to prevent hypoxia. In this manuscript, we develop a computational algorithm to analyze the plasma flow and oxygen concentration within hydrogels featuring various channel geometries. Our objective is to identify the optimal hydrogel channel architecture that sustains oxygen concentration throughout the scaffold above the critical hypoxic threshold. The computational algorithm we introduce here employs a diffuse interface approach to solve a multi-physics problem. The corresponding model couples the time-dependent Stokes equations, governing blood plasma flow through the channel network, with the time-dependent Biot equations, characterizing Darcy velocity, pressure, and displacement within the poroelastic hydrogel containing the transplanted cells. Subsequently, the calculated plasma velocity is utilized to determine oxygen concentration within the scaffold using a diffuse interface advection-reaction-diffusion model. Our investigation yields a scaffold architecture featuring a hexagonal channel network geometry that meets the desired oxygen concentration criteria. Unlike classical sharp interface approaches, the diffuse interface approach we employ is particularly adept at addressing problems with intricate interface geometries, such as those encountered in bioartificial organ scaffold design. This study is significant because recent developments in hydrogel fabrication make it now possible to control hydrogel rheology [20, 14], and utilize computational results to generate optimized scaffold architectures. MSC codes76S05; 76-04; 76D05; 92-10; 92-04

bioengineering↗