bioRxiv Science⌕ Search

Biology subjects

Brower, K.

Publications and source records attributed to Brower, K..

6 recordsLinked to original sources

Double emulsions as a high-throughput enrichment and isolation platform for slower-growing microbes

Our understanding of in situ microbial physiology is primarily based on physiological characterization of fast-growing and readily-isolatable microbes. Microbial enrichments to obtain novel isolates with slower growth rates or physiologies adapted to low nutrient environments are plagued by intrinsic biases for fastest-growing species when using standard laboratory isolation protocols. New cultivation tools to minimize these biases and enrich for less well-studied taxa are needed. In this study, we developed a high-throughput bacterial enrichment platform based on single cell encapsulation and growth within double emulsions (GrowMiDE). We showed that GrowMiDE can cultivate many different microorganisms and enrich for novel taxa that are never observed in traditional batch enrichments. For example, preventing dominance of the enrichment by fast-growing microbes due to nutrient privatization within the double emulsion droplets allowed cultivation of novel Negativicutes and Methanobacteria from stool samples in rich media enrichment cultures. In competition experiments between growth rate and growth yield specialist strains, GrowMiDE enrichments prevented competition for shared nutrient pools and enriched for slower-growing but more efficient strains. Finally, we demonstrated the compatibility of GrowMiDE with commercial fluorescence-activated cell sorting (FACS) to obtain isolates from GrowMiDE enrichments. Together, GrowMiDE + DE-FACS is a promising new high-throughput enrichment platform that can be easily applied to diverse microbial enrichments or screens.

microbiology↗

Loss of vacuolar acidity results in iron sulfur cluster defects and divergent homeostatic responses during aging in Saccharomyces cerevisiae

The loss of vacuolar/lysosomal acidity is an early event during aging that has been linked to mitochondrial dysfunction. However, it is unclear how loss of vacuolar acidity results in age-related dysfunction. Through unbiased genetic screens, we determined that increased iron uptake can suppress the mitochondrial respiratory deficiency phenotype of yeast vma mutants, which have lost vacuolar acidity due to genetic disruption of the vacuolar ATPase proton pump. Yeast vma mutants exhibited nuclear localization of Aft1, which turns on the iron regulon in response to iron sulfur cluster (ISC) deficiency. This led us to find that loss of vacuolar acidity with age in wildtype yeast causes ISC defects and a DNA damage response. Using microfluidics to investigate aging at the single cell level, we observe grossly divergent trajectories of iron homeostasis within an isogenic and environmentally homogeneous population. One subpopulation of cells fails to mount the expected compensatory iron regulon gene expression program, and suffers progressively severe ISC deficiency with little to no activation of the iron regulon. In contrast, other cells show robust iron regulon activity with limited ISC deficiency, which allows extended passage and survival through a period of genomic instability during aging. These divergent trajectories suggest that iron regulation and ISC homeostasis represent a possible target for aging interventions.

molecular biology↗

Live imaging of Aiptasia larvae, a model system for studying coral bleaching, using a simple microfluidic device

Coral reefs, and their associated diverse ecosystems, are of enormous ecological importance. In recent years, coral health has been severely impacted by environmental stressors brought on by human activity and climate change, threatening the extinction of several major reef ecosystems. Reef damage is mediated by a process called coral bleaching where corals, sea anemones, and other cnidarians lose their photosynthetic algal symbionts (genus Symbiodinium) upon stress induction, resulting in drastically decreased host energy harvest and, ultimately, coral death. The mechanism by which this critical cnidarian-algal symbiosis is lost remains poorly understood. Here, we report Traptasia, a simple microfluidic device with multiple traps designed to isolate and image individual live larvae of Aiptasia, a sea anemone model organism, and their algal symbionts over extended time courses. Aiptasia larvae are ~100 m in length, deformable, and highly motile, posing particular challenges for long-term imaging. Using a trap design optimized via fluid flow simulations and polymer bead loading tests, we trapped Aiptasia larvae containing algal symbionts and demonstrated stable imaging for >10 hours. We visualized algal migration within Aiptasia larvae and observed algal expulsion under an environmental stressor. To our knowledge, this device is the first to enable live imaging of cnidarian larvae and their algal symbionts and, in further implementation, could provide important insights into the cellular mechanisms of coral bleaching under different environmental stressors. The device is simple to use, requires minimal external equipment and no specialized training to operate, and can easily be adapted to study a variety of large, motile organisms.

ecology↗

High-throughput chromatin accessibility profiling at single-cell resolution

We have developed a high-throughput single-cell ATAC-seq (assay for transposition of accessible chromatin) method to measure physical access to DNA in whole cells. Our approach integrates fluorescence imaging and addressable reagent deposition across a massively parallel (5184) nano-well array, yielding a nearly 20-fold improvement in throughput (up to ~1800 cells/chip, 4-5 hour on-chip processing time) and cost (~98{cents} per cell) compared to prior microfluidic implementations. We applied this method to measure regulatory variation in Peripheral Blood Mononuclear Cells (PBMCs) and show robust, de-novo clustering of single cells by hematopoietic cell type.

genomics↗

Discovering novel calcineurin inhibitors through quantitative mapping of protein-peptide affinity landscapes

Transient, regulated binding of globular protein domains to Short Linear Motifs (SLiMs) in disordered regions of other proteins drives cellular signaling. Mapping the energy landscapes of these interactions is essential for deciphering and therapeutically perturbing signaling networks, but is challenging due to their weak affinities. We present a powerful technology, MRBLE-pep, that simultaneously quantifies protein binding to a library of peptides directly synthesized on beads containing unique spectral codes. Using computational modeling and MRBLE-pep, we systematically probe binding of calcineurin (CN), a conserved protein phosphatase essential for the immune response and target of immunosuppressants, to the PxIxIT SLiM. We establish that flanking residues and post- translational modifications critically contribute to PxIxIT-CN affinity, and discover CN-inhibitory peptides with unprecedented affinity and therapeutic potential. The quantitative measurements provided by this approach will improve computational modeling efforts, elucidate a broad range of weak protein-SLiM interactions, and revolutionize our understanding of signaling networks.

bioengineering↗

An Open-Source, Programmable Pneumatic Setup for Operation and Automated Control of Single- and Multi-Layer Microfluidic Devices

Microfluidic technologies have been used across diverse disciplines (e.g. high-throughput biological measurement, fluid physics, laboratory fluid manipulation) but widespread adoption has been limited due to the lack of openly disseminated resources that enable non-specialist labs to make and operate their own devices. Here, we report the open-source build of a pneumatic setup capable of operating both single and multilayer (Quake-style) microfluidic devices with programmable scripting automation. This setup can operate both simple and complex devices with 48 device valve control inputs and 18 sample inputs, with modular design for easy expansion, at a fraction of the cost of similar commercial solutions. We present a detailed step-by-step guide to building the pneumatic instrumentation, as well as instructions for custom device operation using our software, Geppetto, through an easy-to-use GUI for live on-chip valve actuation and a scripting system for experiment automation. We show robust valve actuation with near real-time software feedback and demonstrate use of the setup for high-throughput biochemical measurements on-chip. This open-source setup will enable specialists and novices alike to run microfluidic devices easily in their own laboratories.\n\nO_TBL View this table:\norg.highwire.dtl.DTLVardef@d25ba2org.highwire.dtl.DTLVardef@7dfd9eorg.highwire.dtl.DTLVardef@1959573org.highwire.dtl.DTLVardef@186dceaorg.highwire.dtl.DTLVardef@111af70_HPS_FORMAT_FIGEXP M_TBL O_TABLECAPTIONSpecifications table\n\nC_TABLECAPTION C_TBL

bioengineering↗